Simatic Wincc CVE-2014-8551

CRITICAL
Code Injection (CWE-94)
2014-11-26 cve@mitre.org
10.0
CVSS 2.0 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Code injection prevention, sandbox exec
MITRE ATT&CK

2 techniques across 2 tactics: Execution, Initial Access

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 10.0 (CRITICAL). Attack characteristics: network attack vector, low complexity. EPSS exploitation probability: 5.81%.

Exploit ScenarioDerived

A remote attacker could inject and execute arbitrary code within the application by sending crafted requests to the affected application.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
No patch listed yet 5.8% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6. Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Never evaluate user-controlled input as code. Use sandboxing, disable dangerous functions, apply strict input validation.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Code Injection (CWE-94), which allows attackers to inject and execute arbitrary code within the application. The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets. Affected products include: Siemens Simatic Pcs 7, Siemens Simatic Pcs7, Siemens Simatic Tiaportal, Siemens Simatic Wincc.

Know when Simatic Wincc gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 10.0 CRITICAL
AV:N/AC:L/Au:N/C:C/I:C/A:C

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Confidentiality
C
Integrity
C
Availability
C

DescriptionCVE.org

The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets.

Threat Intelligence Overview

EPSS Score
5.8%
Top 9% exploitable
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 5.8%
Patch available No
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

56
Low Medium High Critical
KEV: 0
EPSS: +6
CVSS: +50
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Code Injection CRITICAL

Code injection occurs when an application accepts user input and passes it directly into a language interpreter or evaluator without proper sanitization.

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

Affected Products (CPE)CVE.org

cpe:2.3:a:siemens:simatic_pcs_7:7.1:sp1:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_pcs7:7.1:sp3:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_pcs7:7.1:sp4:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_pcs7:8.0:sp1:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_pcs7:8.0:sp2:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_pcs7:8.1:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_tiaportal:13.0:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_tiaportal:13.0:3:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_tiaportal:13.0:5:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.0:*:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.0:sp1:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.0:sp2:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.0:sp3:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.2:1:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.2:2:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.2:3:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.2:4:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.2:5:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.2:6:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc:7.2:7:*:*:*:*:*:*
+ 2 more
CVE-2016-5743 CRITICAL
9.8 Jul 22

Siemens SIMATIC WinCC before 7.3 Update 10 and 7.4 before Update 1, SIMATIC BATCH before 8.1 SP1 Update 9 as distributed

CVE-2021-40358 CRITICAL
9.9 Nov 09

A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC

CVE-2019-10922 CRITICAL
9.8 May 14

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All

CVE-2023-28829 HIGH
8.8 Jun 13

A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All vers

CVE-2019-10918 HIGH
8.8 May 14

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions <

CVE-2019-10916 HIGH
8.8 May 14

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions <

CVE-2016-9160 HIGH
8.1 Dec 17

A vulnerability in SIEMENS SIMATIC WinCC (All versions < SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions < S

CVE-2022-24287 HIGH
7.8 May 20

A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC

CVE-2021-40359 HIGH
7.7 Nov 09

A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS

CVE-2016-5744 HIGH
7.5 Jul 22

Siemens SIMATIC WinCC 7.0 through SP3 and 7.2 allows remote attackers to read arbitrary WinCC station files via crafted

CVE-2021-40142 HIGH
7.5 Aug 27

In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS)

CVE-2018-4832 HIGH
7.5 Apr 24

A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS