Skip to main content

RUGGEDCOM CROSSBOW EUVDEUVD-2026-98401

| CVE-2026-89203 MEDIUM
Insertion of Sensitive Information Into Sent Data (CWE-201)
2026-10-13 siemens GHSA-432w-69jv-r59x
5.3
CVSS 4.0 · Vendor: siemens
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Authenticate with low-privilege account
  2. Exploit
    Issue unrestricted database query
  3. Execution
    Server returns system-wide records
  4. Impact
    Harvest device/substation/user/schedule data

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V14 - Data Protection Outbound data filtering
Exploitation Conditions

Exploitation requires a valid authenticated session to RUGGEDCOM CROSSBOW (PR:L) with network reachability to the application; it is not remote-unauthenticated. The specific condition is that the attacker must be a legitimate but lower-privileged user who then submits database queries the application fails to scope to their privilege level, returning system-wide inventory (devices, substations, users, scheduled activities). Limiting factors: valid credentials are mandatory, impact is read-only confidentiality disclosure of configuration/topology metadata with no integrity or availability effect, and all deployed versions below V6.0 are affected (upgrade to V6.0 is the remediation boundary).

Impact

This is a moderate-severity information-disclosure flaw (CVSS 4.3) whose signals consistently point to low real-world priority rather than an urgent threat. The CVSS vector (AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N) indicates network reachability with low attack complexity, but critically requires existing low-level authentication (PR:L) and yields only limited confidentiality impact with no integrity or availability effect - consistent with CWE-201 (information exposure) and the description's account of a privilege-boundary bypass on database queries. No EPSS score, KEV listing, or public POC was provided in the input, so there is no evidence of active exploitation or weaponization. SSVC-style reasoning: exploitation status is 'none' (no public exploit identified), technical impact is partial (read-only disclosure), and automatability is questionable since an authenticated session is required. The signals do not conflict - a genuinely authenticated, confidentiality-only issue - so this reads as a legitimate but lower-tier hardening fix best handled on a normal patch cycle, with elevated attention only for high-assurance substation environments where the disclosed topology data (devices, substations, users, schedules) has reconnaissance value.

Exploit ScenarioDerived

An attacker who already holds a valid but low-privilege RUGGEDCOM CROSSBOW account issues database queries that the application fails to restrict to their authorization level, returning system-wide records. This lets them enumerate all managed devices, substations, user accounts, and scheduled activities for reconnaissance, even though their role should not expose that data. No public exploit code was identified at time of analysis, and the attack requires network access plus valid credentials.

This Month Plan within 30 days. Why: MEDIUM severity (CVSS 4.0-6.9).
No patch listed yet 0.3% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Oct 13, 2026

Authenticated users of Siemens RUGGEDCOM CROSSBOW versions below V6.0 can retrieve system-wide infrastructure information-including details on all devices, substations, users, and scheduled activities-because the application fails to restrict database queries to the user's privilege level. This moderate-severity information-disclosure flaw (CVSS 4.3) has no public exploit identified at time of analysis and is not confirmed actively exploited. The impact is limited to read-only confidentiality loss of configuration and topology metadata, with no integrity or availability effects.

RemediationAI

Vendor-released patch: V6.0. Upgrade to RUGGEDCOM CROSSBOW V6.0 or later, which enforces proper privilege scoping on database queries. If immediate upgrade is not possible, restrict network access to the CROSSBOW management interface to trusted administrative hosts, and audit user roles to ensure only necessary accounts have access-though these are temporary mitigations that do not eliminate the underlying flaw. Review the Siemens advisory SSA-508506 for additional guidance and version-specific fixes.

Affected VersionsENISA

RUGGEDCOM CROSSBOW 0 <V6.0

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

RUGGEDCOM CROSSBOW is a Siemens network management and security appliance for substation automation and utility communications. The vulnerability stems from CWE-201 (Insertion of Sensitive Information Into Sent Data): the application executes database queries that return data beyond the authenticated user's privilege scope, effectively leaking sensitive system metadata. The CVSS vector (AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N) indicates network accessibility, low attack complexity, and required low-privilege authentication, with a low confidentiality impact confined to the vulnerable component. All versions below V6.0 are affected per CPE cpe:2.3:a:siemens:ruggedcom_crossbow:*:*:*:*:*:*:*:*.

Know when Ruggedcom Crossbow gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (siemens) PRIMARY 5.3 MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N
vuln.today AI 4.3 MEDIUM

Network-reachable query interface (AV:N/AC:L) but a valid low-privilege account is required (PR:L); only limited read disclosure, so C:L and I:N/A:N.

3.1 AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N

Primary rating from Vendor (siemens).

CVSS VectorVendor: siemens

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
Low
Vulnerable system: Integrity
None
Vulnerable system: Availability
None
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

1
CVSS changed
Oct 13, 2026 - 10:22 NVD
4.3 (MEDIUM) 5.3 (MEDIUM)

DescriptionCVE.org

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly restrict access to various database queries, allowing users to retrieve system-wide information that is not intended for their privilege level. This could allow an authenticated attacker to gather sensitive information about the system's infrastructure, including details on all devices, substations, users, and scheduled activities.

Threat Intelligence Overview

EPSS Score
0.3%
Top 79% exploitable
Prevalence
Low
niche Siemens substation access-management software, utility-sector only
Threat Intel
1
1 sources
Social Media
1
Sightings
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC No
EPSS 0.3%
Patch available No
Active threat Yes
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation
None
System Exposure· derived
Open
Automatable
No
Human Impact· derived
Medium
Technical Impact
Partial

Priority Score

36
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +26
PoC: 0
Weaponized: 0
Threat intel: +10
Gov advisory: 0

Attack Technique

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

CVE-2024-27939 CRITICAL
9.8 May 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). Rated critical severity (CVSS 9.8), thi

CVE-2023-37372 CRITICAL
9.8 Aug 08

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). Rated critical severity (CVSS 9.8), thi

CVE-2023-27463 HIGH
8.8 Mar 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.3). Rated high severity (CVSS 8.8), this vu

CVE-2023-27310 HIGH
8.8 Mar 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.2). Rated high severity (CVSS 8.8), this vu

CVE-2023-27309 HIGH
8.8 Mar 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.2). Rated high severity (CVSS 8.8), this vu

CVE-2024-27941 HIGH
8.8 May 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). Rated high severity (CVSS 8.8), this vu

CVE-2024-27940 HIGH
8.8 May 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). Rated high severity (CVSS 8.8), this vu

CVE-2023-27411 HIGH
8.8 Aug 08

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). Rated high severity (CVSS 8.8), this vu

CVE-2026-89198 HIGH
8.7 Oct 13

SQL injection in the firmware-upload filename handling of Siemens RUGGEDCOM CROSSBOW (all versions prior to V6.0) lets a

CVE-2026-89197 HIGH
8.7 Oct 13

SQL injection in the Value field of notification conditions handled by the Notification Profile configuration in RUGGEDC

CVE-2026-89196 HIGH
8.7 Oct 13

Authenticated SQL injection in Siemens RUGGEDCOM CROSSBOW (all versions prior to V6.0) allows a user with the specific p

CVE-2026-89199 HIGH
8.7 Oct 13

Authenticated, low-privilege users of Siemens RUGGEDCOM CROSSBOW running any version earlier than V6.0 can bypass access

Threat IntelligenceMISP

CISA Advisories
Sources: CISA Vulnrichment, CISA (public domain)

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy