Skip to main content

RUGGEDCOM CROSSBOW CVE-2026-89199

| EUVDEUVD-2026-98397 HIGH
Authorization Bypass Through User-Controlled Key (CWE-639)
2026-10-13 siemens GHSA-cjf3-3mcw-2vg2
8.7
CVSS 4.0 · Vendor: siemens
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Obtain low-privilege CROSSBOW account
  2. Delivery
    Reach configuration database query interface
  3. Exploit
    Issue crafted query bypassing access control
  4. Execution
    Retrieve stored administrative credentials
  5. Impact
    Reuse credentials to escalate and pivot across internal systems

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V8 - Authorization Object-level authorization, IDOR prevention
Exploitation Conditions

Exploitation requires an authenticated session on RUGGEDCOM CROSSBOW (CVSS PR:L confirms low-but-nonzero privileges are needed) with network access to the service's database/configuration query interface. The specific precondition is the ability to submit the 'specific database queries' that reach sensitive configuration items whose access controls are not properly enforced (CWE-639). Limiting factors: the attacker must already possess valid credentials or a foothold account, so a purely external unauthenticated attacker cannot exploit this directly; impact is highest where CROSSBOW stores and brokers credentials for many downstream internal/OT systems. All versions below V6.0 are affected, so upgrading to V6.0 removes the condition.

Impact

Multiple signals converge on a credible but conditional threat. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H) yields an 8.7 (High), driven by network reachability, low complexity, and high impact across confidentiality, integrity, and availability - but it explicitly requires existing privileges (PR:L), so this is an authenticated attack, not a drive-by. CWE-639 (authorization bypass through user-controlled key / IDOR) matches the description: an already-authenticated user escalates by querying configuration items they should not reach. No EPSS score was provided, this CVE is NOT in CISA KEV, and no POC was referenced, so there is no public exploit identified at time of analysis. The key amplifier is the nature of the leaked data - administrative credentials for various internal/managed systems - meaning a single low-privilege foothold can cascade into broad OT/substation network compromise. On balance this is a real, prioritize-for-patching issue for anyone running RUGGEDCOM CROSSBOW < V6.0, but it is a post-authentication privilege-escalation flaw rather than a wormable internet-facing RCE, so urgency scales with how exposed the management interface is and how many low-trust accounts exist. Note the limited intelligence: only a single Siemens advisory reference is available; EPSS and exploitation telemetry are absent, so the 'real-world exploited' likelihood cannot be independently quantified.

Exploit ScenarioDerived

An attacker with a valid low-privilege RUGGEDCOM CROSSBOW account (e.g., a limited operator or a compromised user credential) issues crafted database queries against configuration items that lack proper access restriction. The response discloses stored administrative credentials for the internal systems CROSSBOW brokers access to, which the attacker then reuses to pivot and gain administrative control. No public exploit code is known, and the attack requires prior authentication and network access to the management service.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.3% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv2 – Oct 13, 2026

Authenticated, low-privilege users of Siemens RUGGEDCOM CROSSBOW running any version earlier than V6.0 can bypass access controls on sensitive configuration records and retrieve administrative credentials for various internal systems, yielding unauthorized information disclosure and follow-on privilege escalation. The defect is an authorization bypass through a user-controlled key (CWE-639) that is network-reachable with low attack complexity but requires a valid session, consistent with the CVSS 4.0 vector's PR:L and high confidentiality, integrity and availability impact confined to the CROSSBOW system itself. No public exploit code or confirmed active exploitation has been identified at time of analysis, and Siemens has released V6.0 to correct the condition.

Earlier versions of this analysis (1)
v1 Oct 13, 2026 - 10:06 CVSS 8.8

An authenticated attacker holding only a low-privilege session on Siemens RUGGEDCOM CROSSBOW (all versions below V6.0) can issue specific database queries that are not properly restricted and retrieve administrative credentials for various internal systems, escalating privileges and disclosing sensitive configuration data. Exploitation requires a valid low-privilege account (CVSS vector PR:L) and network reachability to the device's management interface, but no user interaction; the Siemens-assigned base score is 8.8, and an independent assessment raises the scope impact to Changed (S:C) because the stolen credentials grant access to systems beyond CROSSBOW itself. There is no public exploit identified at time of analysis and the issue is not confirmed actively exploited (CISA KEV); the risk is best characterized as a credible, actionable priority within OT/industrial environments rather than a mass-exploitation threat, given the pre-existing account requirement and the typically segmented substation/management network placement of CROSSBOW deployments.

RemediationAI

Vendor-released patch: upgrade RUGGEDCOM CROSSBOW to V6.0 or later as instructed in Siemens SSA-508506 (https://cert-portal.siemens.com/productcert/html/ssa-508506.html), which removes the missing-access-control condition affecting all versions below V6.0. Where the upgrade cannot be applied immediately, restrict network access to the CROSSBOW configuration/database query interface to trusted management networks and administrative hosts, accepting that legitimate remote administrators must then route through those hosts; enforce least privilege so that only a minimal set of accounts holds even the low-level session required to reach the vulnerable queries, recognizing that the flaw is exploitable by any authenticated user and therefore this only reduces rather than eliminates exposure; and treat any pre-upgrade window as a potential credential-compromise scenario by rotating administrative credentials for the internal systems brokered by CROSSBOW and reviewing configuration-query logs for bulk or anomalous retrieval. Because no public exploit code has been identified at time of analysis, monitoring and credential hygiene are more appropriate than emergency exploit-specific blocking.

Affected VersionsENISA

RUGGEDCOM CROSSBOW 0 <V6.0

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The root cause is CWE-639, Authorization Bypass Through User-Controlled Key: the CROSSBOW configuration/database query layer fails to verify that the requesting principal is authorized for the specific configuration items being fetched, so an authenticated user with only low privileges can supply or manipulate record identifiers to read entries they should not see, including administrative credentials for downstream internal systems. CROSSBOW is Siemens' OT network management and configuration platform for Ruggedcom and related devices, and its credential store brokers access to many internal systems, which is why a read-only authorization failure escalates into a wider compromise path. The provided CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:L/UI:N, VC:H/VI:H/VA:H, SC:N/SI:N/SA:N) describes network reachability with no special attack requirements, pre-existing low privileges, and high impact on confidentiality, integrity and availability of the vulnerable system only, with no subsequent-system impact scored; the independently assessed CVSS 3.1 vector (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) aligns with that reading and confirms that authentication requirements are low but non-zero.

Know when Ruggedcom Crossbow gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (siemens) PRIMARY 8.7 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
vuln.today AI 8.8 HIGH

Network-reachable management interface (AV:N) with low complexity (AC:L) but requires an existing authenticated account (PR:L); credential disclosure and resulting escalation justify high C/I/A.

3.1 AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (siemens).

CVSS VectorVendor: siemens

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

2
CVSS changed
Oct 13, 2026 - 10:22 NVD
8.8 (HIGH) 8.7 (HIGH)
CVE Published
Oct 13, 2026 - 09:19 cve.org
HIGH 8.8

DescriptionCVE.org

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly restrict access to sensitive configuration items via specific database queries. This could allow an authenticated attacker to retrieve administrative credentials for various internal systems, leading to unauthorized information disclosure and privilege escalation.

Executive ViewAI

Why It Matters

Siemens RUGGEDCOM CROSSBOW, a platform commonly used in utility and industrial environments to broker access to operational field devices, can leak stored administrative credentials for connected internal systems to any valid low-privilege user of the application. Although exploitation requires an existing account and no public exploit has been identified, the consequence is a pivot path from a single hardened appliance into the broader operational estate. Leadership should care because the credentials exposed typically unlock grid, substation, and industrial control assets, turning an access-control defect into potential operational disruption.

Business Impact: High
Compensating Controls

Structured patch data lists no vendor patch, but the advisory identifies V6.0 as the release that corrects the condition - apply the vendor patch by upgrading to V6.0. Until then: restrict network reachability of CROSSBOW management interfaces to trusted administrative segments, minimize and audit low-privilege accounts, rotate all credentials that CROSSBOW stores or brokers for internal systems, relocate those secrets to a privileged-access vault, and monitor configuration-record access for anomalous enumeration.

Threat Intelligence Overview

EPSS Score
0.3%
Top 74% exploitable
Prevalence
Low
niche Siemens OT access-management software for substation environments
Social Media
1
Sightings
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.3%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Open
Automatable
No
Human Impact
High
Technical Impact
Total

Priority Score

44
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +44
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Privilege escalation occurs when an attacker leverages flaws in access control mechanisms to gain permissions beyond what they were originally granted.

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

CVE-2024-27939 CRITICAL
9.8 May 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). Rated critical severity (CVSS 9.8), thi

CVE-2023-37372 CRITICAL
9.8 Aug 08

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). Rated critical severity (CVSS 9.8), thi

CVE-2024-27941 HIGH
8.8 May 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). Rated high severity (CVSS 8.8), this vu

CVE-2024-27940 HIGH
8.8 May 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). Rated high severity (CVSS 8.8), this vu

CVE-2023-27411 HIGH
8.8 Aug 08

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). Rated high severity (CVSS 8.8), this vu

CVE-2023-27463 HIGH
8.8 Mar 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.3). Rated high severity (CVSS 8.8), this vu

CVE-2023-27310 HIGH
8.8 Mar 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.2). Rated high severity (CVSS 8.8), this vu

CVE-2023-27309 HIGH
8.8 Mar 14

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.2). Rated high severity (CVSS 8.8), this vu

CVE-2026-89198 HIGH
8.7 Oct 13

SQL injection in the firmware-upload filename handling of Siemens RUGGEDCOM CROSSBOW (all versions prior to V6.0) lets a

CVE-2026-89197 HIGH
8.7 Oct 13

SQL injection in the Value field of notification conditions handled by the Notification Profile configuration in RUGGEDC

CVE-2026-89196 HIGH
8.7 Oct 13

Authenticated SQL injection in Siemens RUGGEDCOM CROSSBOW (all versions prior to V6.0) allows a user with the specific p

CVE-2026-89200 HIGH
8.4 Oct 13

SQL injection in RUGGEDCOM CROSSBOW versions below V6.0 lets an attacker who already holds administrative credentials in

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy