Skip to main content

Budibase Server EUVDEUVD-2026-87660

| CVE-2026-100687 HIGH
Information Exposure (CWE-200)
2026-09-26 VulnCheck GHSA-qhcg-hgqm-ww52
7.0
CVSS 4.0 · Vendor: VulnCheck
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Obtain Builder access to workspace
  2. Delivery
    Join Builder collaboration websocket room
  3. Exploit
    Observe table save/delete broadcast
  4. Execution
    Capture unredacted datasource object
  5. Persist
    Extract plaintext DB password/API key
  6. Impact
    Authenticate to external datasource

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V14 - Data Protection Data exposure prevention
MITRE ATT&CK

2 techniques across 2 tactics: Collection, Discovery

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Requires an account with Builder access to the target Budibase workspace and access to the Builder collaboration websocket room (the real-time co-editing channel). Exploitation is triggered passively by observing when any collaborator performs a table save or delete operation on an external datasource - the server broadcasts the datasource object with credentials unredacted before version 3.45.0. Limiting factors: the attacker must already hold the privileged Builder role (PR:H), the affected datasources must be external tables with stored credentials (database passwords or API keys), and the target must be running Budibase Server prior to 3.45.0; this is not exploitable by unauthenticated or low-privilege end users of published apps.

Impact

The vendor CVSS 4.0 vector (7.0) rates this High, but the metrics themselves temper the real-world risk: exploitation requires PR:H (Builder-level access to the Budibase workspace), the impact is confidentiality-only with a slight integrity spillover (VC:H/VI:L/VA:N), and there is no scope change (SC:N/SI:N/SA:N). No EPSS score, no CISA KEV listing, and no public exploit were provided, so this is 'no public exploit identified at time of analysis' - there is no evidence of active or automatable exploitation. The signals are internally consistent: a network-reachable websocket (AV:N/AC:L) but gated behind an already-privileged collaborator role. The practical danger is that the leaked material is plaintext datasource passwords and API keys, so a malicious or compromised Builder account converts into credentials for backend databases and third-party APIs - a meaningful pivot even though the initial access bar is high. Net assessment: a legitimately High-scoring confidentiality flaw for multi-tenant/multi-collaborator Budibase deployments, but not an emergency mass-exploitation issue - it is a privileged-insider / lateral-movement concern rather than an unauthenticated internet threat.

Exploit ScenarioDerived

A user (or attacker who has phished/obtained an account) with Builder access to a Budibase workspace opens the collaboration interface and monitors the Builder websocket room. When any collaborator saves or deletes an external table, the server broadcasts the full, unredacted datasource object, so the attacker captures the backing database password or third-party API key in plaintext and reuses it to reach the external system directly. No public exploit code is known, but interception requires only observing normal websocket traffic, not a crafted payload.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
Patch available 0.3% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Sep 26, 2026

Budibase Server before 3.45.0 fails to redact plaintext datasource credentials before broadcasting external table updates to the Builder collaboration websocket room, allowing anyone already holding Builder-level access to a workspace to passively capture database passwords and API keys whenever a collaborator saves or deletes a table on an external datasource. The exposure is confidentiality-dominant (CVSS 4.0 base 7.0; VC:H/VI:L/VA:N) and requires the privileged Builder role (PR:H) - it is not reachable by unauthenticated users or by low-privilege consumers of published apps. No public exploit code was identified at time of analysis and the flaw is not in CISA KEV; a vendor patch is available in 3.45.0.

RemediationAI

Upgrade Budibase Server to version 3.45.0 or later, the vendor-released fix that restores credential redaction on collaboration-room broadcasts, following the vendor advisory at https://github.com/Budibase/budibase/security/advisories/GHSA-rmv5-3xpj-w885 and the VulnCheck advisory at https://www.vulncheck.com/advisories/budibase-server-before-3.45.0-credential-exposure-via-external-table-broadcast. Because the disclosed secrets must be assumed compromised, treat patching as necessary but not sufficient: rotate every database password and API key stored in Budibase external datasource configurations after upgrading, accepting the operational cost of updating downstream consumers and any scripts that embed the old credentials. Until upgrade is possible, restrict Builder role membership to fully trusted personnel and avoid granting Builder access to contractors or shared accounts - this narrows the audience of the websocket room but does not remove the disclosure, since any legitimate Builder user can still observe the payload; a stronger interim measure is to temporarily move external tables to datasources that authenticate via short-lived tokens rather than long-lived static secrets, at the cost of reconfiguration effort. Disabling the collaboration/websocket feature, if your build permits it, prevents the broadcast entirely but removes real-time co-editing and can leave the Builder UI in an inconsistent state for multiple concurrent editors; network-level controls such as limiting who can reach the Builder interface reduce exposure but do not mitigate an insider who already holds the role. There is no indication that closing or filtering the websocket port is a supported configuration, so credential rotation plus upgrade remains the recommended path.

Affected VersionsENISA

Server 0 <3.45.0

Affected Packages

euvd server fix: 3.45.0

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

Budibase is a low-code platform whose Builder is a browser-based application editor with a real-time co-editing channel implemented over a websocket 'collaboration room', where every connected Builder client receives server-pushed state updates for objects in the workspace. External datasource definitions (SQL connection strings, database passwords, service API keys) are persisted server-side so that table operations against those external tables can be executed; the server serializes these datasource objects when notifying the room of table save and delete events. Prior to 3.45.0 that serialization omitted credential redaction, so the full plaintext secret material was included in the broadcast payload delivered to every client in the room rather than being stripped or replaced with masked values. This is an instance of CWE-200 (Exposure of Sensitive Information to an Unauthorized Actor) driven by insufficient sanitization of data crossing a shared real-time channel - the trust boundary between the server's privileged internal representation and the multi-client collaboration bus is not enforced. The tracked CPE cpe:2.3:a:budibase:server:*:*:*:*:*:*:*:* matches all server builds prior to the fix, and ENISA EUVD records the affected range as Server 0 <3.45.0.

Know when Budibase gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (VulnCheck) PRIMARY 7.0 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N
vuln.today AI 4.9 MEDIUM

Builder role is a privileged collaborator role so PR:H; network-reachable websocket with no user interaction; confidentiality-only plaintext credential leak, no integrity or availability impact.

3.1 AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
4.0 AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

Primary rating from Vendor (VulnCheck).

CVSS VectorVendor: VulnCheck

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
High
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
Low
Vulnerable system: Availability
None
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

2
Patch available
Sep 26, 2026 - 14:02 EUVD
CVE Published
Sep 26, 2026 - 13:23 cve.org
HIGH 7.0

DescriptionCVE.org

Budibase Server before 3.45.0 fails to redact plaintext datasource credentials before broadcasting external table updates to the Builder collaboration websocket room. Attackers with Builder access can intercept unredacted datasource objects containing database passwords and API keys by observing table save or delete operations.

Technical POC Analysis

CWE-200 (Exposure of Sensitive Information to an Unauthorized Actor).

Full technical POC analysis - root cause, step-by-step exploitation and patch breakdown - is part of the Pro and Business plans.

Executive ViewAI

Why It Matters

Budibase Server versions before 3.45.0 can expose plaintext datasource credentials to authenticated users with the Builder role, allowing them to passively capture database passwords and API keys during routine collaboration. This creates a confidentiality risk for connected databases and APIs, so leadership should care because trusted internal users could gain unauthorized access to sensitive systems. No public exploit identified at time of analysis, and Vendor-released patch: 3.45.0 is available.

Business Impact: High
Compensating Controls

Apply vendor patch.

Threat Intelligence Overview

EPSS Score
0.3%
Top 84% exploitable
Prevalence
Medium
popular open-source low-code platform, self-hosted, moderate production footprint
Data Quality
6 sources
Confidence: High

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.3%
Patch available Yes
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Open
Automatable
No
Human Impact
High
Technical Impact
Partial

Priority Score

35
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +35
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

CVE-2026-27702 CRITICAL POC
9.9 Feb 25

Unauthorized data access in Budibase low-code platform before 3.30.4 allows unauthenticated users to manipulate internal

CVE-2026-73300 CRITICAL POC
9.6 Aug 12

SQL injection in Budibase's MySQL integration (all versions prior to 3.40.0) lets attackers execute arbitrary, stacked S

CVE-2026-31816 CRITICAL POC
9.1 Mar 09

Authorization bypass in Budibase 3.31.4 and earlier. The authorized() middleware can be bypassed, enabling injection att

CVE-2026-41428 CRITICAL POC
9.1 Apr 24

Authentication bypass in Budibase low-code platform (versions prior to 3.35.4) allows remote unauthenticated attackers t

CVE-2026-25040 HIGH POC
8.8 Jan 29

Budibase is a low code platform for creating internal tools, workflows, and admin panels. [CVSS 8.8 HIGH]

CVE-2026-122247 HIGH POC
8.2 Nov 20

Unauthenticated remote attackers can defeat the one-time initialization lock on self-hosted, single-tenant Budibase depl

CVE-2026-73406 HIGH POC
7.5 Aug 12

Unauthenticated user enumeration and metadata disclosure in Budibase prior to 3.39.32 exposes tenant identifiers, email

CVE-2026-31818 CRITICAL
9.9 Apr 03

Server-Side Request Forgery (SSRF) in Budibase's REST datasource connector (versions prior to 3.33.4) allows authenticat

CVE-2026-73308 MEDIUM POC
5.7 Aug 12

OAuth2 access and refresh token theft in Budibase's automation testing pipeline exposes SSO-authenticated builder creden

CVE-2022-3225 MEDIUM POC
5.7 Sep 16

Improper Control of Dynamically-Managed Code Resources in GitHub repository budibase/budibase prior to 1.3.20. Rated med

CVE-2026-30240 CRITICAL
9.6 Mar 09

Path traversal in Budibase low-code platform 3.31.5 and earlier allows attackers to read arbitrary files through the app

CVE-2026-82244 CRITICAL
9.4 Aug 28

Remote code execution in Budibase self-hosted server before 3.41.3 lets authenticated administrators run arbitrary JavaS

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy