Lantronix SLC8000 EUVDEUVD-2026-84521

| CVE-2026-80155 CRITICAL
Path Traversal (CWE-22)
2026-09-22 VulnCheck GHSA-h7c7-c453-99x2
10.0
CVSS 4.0 · Vendor: VulnCheck
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Reach web management portal
  2. Delivery
    Send crafted cookie length to upload endpoint
  3. Exploit
    Truncate snprintf path and traverse to user DB
  4. Execution
    Bypass session authentication
  5. Persist
    Write file to arbitrary location
  6. Impact
    Execute code and pivot to serial devices

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V5 - File Handling Path canonicalization, traversal prevention
MITRE ATT&CK

2 techniques across 2 tactics: Discovery, Collection

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

No special conditions beyond network reachability of the web management portal - remote unauthenticated exploitation against default configurations of Lantronix SLC8000, EMG8500/EMG7500, SLB882, and SLCx-03/SLCx-02 devices. The attacker only needs HTTP access to the web configuration server's upload endpoint and supplies a cookie value of a specific length to trigger the snprintf path truncation; no credentials, user interaction, or non-default settings are required. The primary limiting factor is network exposure of the management interface: risk is highest where the portal is internet- or management-network-facing, and lower where it is isolated. Patched firmware exists for SLC8000 (9.7.0.5) and EMG8500/EMG7500 (9.7.0.1), but SLB882/SLCx-03/SLCx-02 are affected in all firmware versions.

Impact

This is a genuine top-tier priority, not a high-CVSS-but-low-real-risk case. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:N with full VC:H/VI:H/VA:H and subsequent-system SC:H/SI:H/SA:H) scores a maximal 10.0, and the description substantiates every metric: a remote, unauthenticated attacker manipulates a session-cookie length to force an snprintf path truncation and path-traversal that redirects auth validation to an arbitrary on-disk file (e.g. the local user database), fully bypassing session checks, then reads config and writes files to arbitrary locations for RCE. The attack is deterministic (fixed-size buffer truncation at a known delimiter), so AC:L is well-justified and no user interaction or authentication is needed. EPSS and CISA KEV data were not provided in the input, so exploitation-probability and active-exploitation signals cannot be confirmed here; absence of a KEV entry should not be read as low risk given the trivially reproducible, unauthenticated nature. The flaw was reported by VulnCheck with a public technical advisory and an independent writeup (revrb.net), which meaningfully lowers the barrier to weaponization even though no packaged exploit code is confirmed in the input. Note the affected SLB882/SLCx-03/SLCx-02 lines are flagged as vulnerable across ALL firmware versions with fixes only shipped for SLC8000/EMG models, meaning some products have no patched build listed - an important gap for defenders.

Exploit ScenarioDerived

An attacker who can reach the device's web management portal (often exposed for out-of-band/remote administration) sends a crafted request to the upload endpoint with a cookie value of a specific length, causing the server's snprintf-built cookie file path to truncate and traverse to an arbitrary file, bypassing all session authentication. With authentication defeated, the attacker reads sensitive configuration and writes a file to an arbitrary filesystem location to achieve remote code execution as the web server. Detailed public advisories from VulnCheck and revrb.net describe the mechanism, though no packaged exploit is confirmed in the provided data.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
Patch available 1.6% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Sep 22, 2026

Unauthenticated remote attackers can completely compromise the web management portal of Lantronix console servers, reading sensitive configuration files, writing files to arbitrary filesystem locations, and ultimately achieving remote code execution. Affected are SLC8000 units below firmware 9.7.0.5, EMG8500/EMG7500 units below firmware 9.7.0.1, and SLB882/SLCx-03/SLCx-02 devices, which are vulnerable in every firmware version released to date. The assessed vector (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H; vendor CVSS 4.0 score 10.0) requires nothing more than HTTP reachability to the portal upload endpoint - no credentials, user interaction or non-default settings - and exploitation yields total loss of confidentiality, integrity and availability on the device plus potential impact on serial-connected downstream equipment; no public exploit code has been identified at time of analysis, though a third-party technical writeup accompanies the disclosure.

RemediationAI

Vendor-released patch: upgrade Lantronix SLC8000 to firmware 9.7.0.5 (image published as 9.7.0.5R2 at https://ts.lantronix.com/ftp/slc8000/9.7.0.5R2/) and EMG8500/EMG7500 to firmware 9.7.0.1 (images published as 9.7.0.1R2 at https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ and https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/), then verify the running version after reboot. No vendor-released patch is identified for SLB882, SLCx-03 or SLCx-02, which are vulnerable in all firmware versions; for these, treat the web management portal as an untrusted, permanently exploitable service and apply compensating controls. Immediately remove the web configuration server from any internet-facing or broadly routable network: block TCP/80 and TCP/443 (and any non-standard management HTTP ports) at the perimeter and on management-network ACLs, and place the portal on a dedicated, tightly scoped management VLAN reachable only from a hardened jump host or VPN - the trade-off is loss of out-of-band reachability from general corporate networks, so ensure serial/console and SSH/CLI access paths remain available for recovery. Where the web UI is not required, disable it entirely and administer the device through the CLI over SSH or the local console port; this eliminates the attack surface but removes browser-based configuration and file upload capabilities. If the portal must remain reachable, front it with an authenticating reverse proxy or VPN gateway that enforces its own session handling, since the device's own session validation cannot be trusted; be aware that this adds a dependency on the proxy's availability. Network monitoring should alert on HTTP requests to the upload endpoint with unusually long or delimiter-containing Cookie values, as these are the signature of attempted exploitation, and any device suspected of prior compromise should be assumed to have had its local user database and configuration read, with credentials rotated and firmware re-imaged rather than simply patched.

Affected VersionsENISA

SLCx-02 *
EMG8500 0 <9.7.0.1
SLB882 *
EMG7500 0 <9.7.0.1
SLCx-03 *
SLC8000 0 <9.7.0.5

Affected Packages

euvd emg7500 fix: 9.7.0.1
euvd emg8500 fix: 9.7.0.1
euvd slc8000 fix: 9.7.0.5

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 3 packages in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The flaw is a CWE-22 path traversal compounded by a classic C buffer-truncation bug in the web configuration server of Lantronix out-of-band/console management appliances. When validating a session, the server builds the on-disk path of the session cookie file with snprintf() into a fixed-size buffer. Supplying a cookie value of a carefully chosen length causes the concatenated string to be truncated exactly at the path delimiter, so the intended session-directory prefix is lost and the resulting traversal sequence points the session lookup at an arbitrary file on disk - for example the local user database. Because the file chosen by the attacker is then treated as the session store, all authentication checks are satisfied and the attacker is treated as a legitimate authenticated user of the web management portal. From that position the upload endpoint can be abused to read sensitive configuration files and to drop files into arbitrary filesystem locations, which escalates to remote code execution. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H) confirms a network-reachable, unauthenticated, no-interaction attack with subsequent-system impact - significant here because these appliances are serial-attached gateways to switches, routers, PDUs and other downstream infrastructure. The exposure maps to CPE entries for lantronix:slc8000, lantronix:emg8500, lantronix:emg7500, lantronix:slb882, lantronix:slcx-03 and lantronix:slcx-02.

Know when Slc8000 gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (VulnCheck) PRIMARY 10.0 CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
vuln.today AI 10.0 CRITICAL

Remote, unauthenticated, deterministic path-truncation bypass yields full RCE (PR:N/AC:L); S:C because device compromise extends to downstream serial-connected devices beyond the web server's authorization scope.

3.1 AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

Primary rating from Vendor (VulnCheck).

CVSS VectorVendor: VulnCheck

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
High
Subsequent system: Integrity
High
Subsequent system: Availability
High

DescriptionCVE.org

Lantronix SLC8000 before firmware v9.7.0.5, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain an authentication bypass vulnerability in the web management portal upload endpoint that allows unauthenticated attackers to read sensitive configuration files and upload files to arbitrary filesystem locations, leading to remote code execution. The web configuration server constructs the session cookie file path using snprintf with a fixed-size buffer; by supplying a cookie value of a specific length an attacker causes the path to truncate at the required delimiter and leverages path traversal to redirect authentication validation to an arbitrary on-disk file such as the local user database, bypassing all session checks. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices.

Executive ViewAI

Why It Matters

Lantronix console server web management portals are exposed to unauthenticated remote code execution, allowing full device compromise and possible disruption to serial-connected operational equipment. This affects organizations using affected SLC8000, EMG8500/EMG7500, SLB882, SLCx-03, or SLCx-02 models for out-of-band management, and leadership should treat it as an urgent risk because exploitation requires only network reachability to the portal upload endpoint.

Business Impact: Severe
Compensating Controls

Apply vendor patch.

Threat Intelligence Overview

EPSS Score
1.6%
Top 26% exploitable
Prevalence
Low
Niche vendor out-of-band console/terminal server appliances, specialized datacenter/industrial deployment
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 1.6%
Patch available Yes
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Out-of-Cycle
Exploitation
None
System Exposure· derived
Open
Automatable
Yes
Human Impact
Very High
Technical Impact
Total

Priority Score

52
Low Medium High Critical
KEV: 0
EPSS: +2
CVSS: +50
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.

Path traversal exploits occur when applications use user-controlled input to construct file system paths without proper validation.

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

CVE-2026-80144 CRITICAL
9.4 Sep 22

Authenticated command injection in Lantronix out-of-band console managers (SLC8000, EMG8500/EMG7500, SLB882, SLCx-03, SL

CVE-2026-80143 CRITICAL
9.4 Sep 22

Authenticated OS command injection in Lantronix out-of-band management appliances (SLC8000, EMG8500, EMG7500, SLB882, SL

CVE-2026-80152 CRITICAL
9.4 Sep 22

Authenticated command injection in Lantronix SLC8000 console servers (before firmware v9.7.0.3), EMG8500/EMG7500 (before

CVE-2026-80151 CRITICAL
9.4 Sep 22

Root-level command injection in Lantronix console servers - SLC8000, EMG8500, EMG7500, SLB882, SLCx-03 and SLCx-02 - let

CVE-2026-80145 CRITICAL
9.4 Sep 22

Authenticated command injection in Lantronix console/out-of-band management appliances (SLC8000, EMG8500, EMG7500, SLB88

CVE-2026-80156 CRITICAL
9.4 Sep 22

Authenticated file-write path traversal in the Lantronix web management portal lets a logged-in attacker upload a crafte

CVE-2026-80147 CRITICAL
9.4 Sep 22

An authenticated stack-based buffer overflow in Lantronix SLC8000, EMG8500/EMG7500, SLB882 and SLCx-02/SLCx-03 console m

CVE-2026-80146 CRITICAL
9.4 Sep 22

Authenticated remote code execution in Lantronix SLC8000, EMG8500/EMG7500, SLB882, SLCx-03, and SLCx-02 console servers

CVE-2026-80154 HIGH
8.9 Sep 22

Predictable session-token generation in the web management portal of Lantronix SLC8000, EMG8500, EMG7500, SLB882, SLCx-0

CVE-2026-80150 HIGH
7.7 Sep 22

Server-side request forgery in the WebSSH/WebTelnet listener of Lantronix SLC8000 (before firmware 9.7.0.3), EMG8500/EMG

CVE-2026-80149 HIGH
7.7 Sep 22

Unauthenticated server-side request forgery in the Lantronix SLC8000, EMG8500/EMG7500 and SLB882 console servers lets an

CVE-2026-80148 HIGH
7.7 Sep 22

Unauthenticated server-side request forgery in the WebSSH/WebTelnet web terminal listener of Lantronix SLC8000 console s

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy