Skip to main content

Lantronix SLC8000 EUVDEUVD-2026-84517

| CVE-2026-80151 CRITICAL
OS Command Injection (CWE-78)
2026-09-22 VulnCheck GHSA-h8x4-hr84-5rp5
9.4
CVSS 4.0 · Vendor: VulnCheck
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Authenticate to terminal/CLI with services permission
  2. Delivery
    Issue 'set nfs download' with injected metacharacters
  3. Exploit
    Unsanitized input reaches system() call
  4. Execution
    Shell command executes as root
  5. Impact
    Full device compromise and pivot to serial-attached devices

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization OS command sanitization, avoid shell exec
MITRE ATT&CK

2 techniques across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Exploitation requires an authenticated account holding the specific 'services' permission with access to the device's terminal or CLI interface; the payload is delivered through the 'set nfs download' command's unsanitized parameter, which flows into a system() call executed as root. Affected: Lantronix SLC8000 before v9.7.0.3, EMG8500/EMG7500 before v9.7.0.1, and ALL firmware of SLB882/SLCx-03/SLCx-02 (no fixed build published for the latter three - a hard limiting note for defenders). Limiting factors: the services-permission privilege gate (PR:H) means it is not exploitable by anonymous/unauthenticated attackers or by low-privilege users lacking that role; no user interaction is needed once that privilege is held.

Impact

This is a genuine high-priority issue, not an inflated CVSS score. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H, 9.4) describes network-reachable, low-complexity command injection yielding root and full triad loss on the device plus scope-crossing impact to serial-attached downstream systems. The only real brake is PR:H - the attacker must already hold the 'services' permission and authenticate to the terminal/CLI interface - so this is a privilege-escalation-to-root / lateral-movement primitive rather than an unauthenticated takeover. No EPSS score was provided and the flaw is NOT in CISA KEV, so there is no evidence of active mass exploitation; however, a detailed third-party technical write-up (revrb.net 'revrb-lantern') and a VulnCheck advisory are published, which lowers the bar to weaponization considerably. The key conflicting/missing signals: no explicit POC=YES flag or EPSS value is supplied, so exploitation likelihood must be inferred from the public technical disclosures rather than confirmed telemetry. Because these are out-of-band/console management devices (attractive to attackers as a pivot into managed infrastructure), realistic risk is elevated despite the authentication requirement.

Exploit ScenarioDerived

An attacker who has obtained (or been delegated) the 'services' permission authenticates to the SLC/EMG/SLB device's terminal or CLI, then runs the 'set nfs download' command with a shell metacharacter payload in the unsanitized parameter, which is passed to system() and executed as root. This grants full control of the console server and a pivot to any serial-attached downstream equipment. Public technical write-ups (revrb.net and VulnCheck advisory) document the flaw, so working exploit details are effectively available even though no formal POC flag is set.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
Patch available 2.5% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Sep 22, 2026

Root-level command injection in Lantronix console servers - SLC8000, EMG8500, EMG7500, SLB882, SLCx-03 and SLCx-02 - lets an authenticated user who holds the 'services' permission run arbitrary shell commands as root by abusing the 'set nfs download' command, whose parameter is passed unsanitized into a system() call, resulting in complete loss of confidentiality, integrity and availability on the device and potential downstream impact on serial-attached equipment. The privilege gate (PR:H) means anonymous or low-privilege users cannot trigger it and no user interaction is required once that role is held; authentication requirements are confirmed as privileged/authenticated by both the CVSS 4.0 vector (PR:H) and our assessed CVSS 3.1 vector (PR:H). There is no public exploit identified at time of analysis and the issue is not listed in CISA KEV, so this is a high-severity-but-not-currently-exploited defect. Lantronix has shipped firmware v9.7.0.3R3 for SLC8000 and v9.7.0.1R2 for EMG8500/EMG7500, while no fixed build has been published for SLB882, SLCx-03 or SLCx-02.

RemediationAI

Primary fix: upgrade to vendor firmware - Lantronix SLC8000 to v9.7.0.3R3 (https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/), and EMG8500/EMG7500 to v9.7.0.1R2 (https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ and https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/), because those are the only vendor-released patched builds identified; SLB882, SLCx-03 and SLCx-02 have no fixed firmware at time of analysis, so owners of those models must rely on compensating controls until Lantronix ships a build. Most effective compensating control is privilege reduction: audit and strip the 'services' permission from all but the smallest possible set of trusted administrator accounts and rotate credentials for anyone who ever held it, since the vulnerability is unreachable without that role - the trade-off is that legitimate NFS-based configuration/backup workflows performed by those accounts must be reassigned to a designated administrator. If NFS file transfer is not operationally required, disable or block use of the 'set nfs download' function and firewall the unit's NFS egress so a crafted parameter cannot reach a shell, at the cost of losing remote configuration restore over NFS. Additionally, keep the terminal/CLI (SSH/Telnet, serial) and web management interfaces on a dedicated out-of-band management VLAN reachable only from jump hosts, disable Telnet and any unused CLI transports in favor of SSH, enable CLI/audit logging and alert on 'set nfs download' invocations containing shell metacharacters (;, |, $, backticks, &&), and review serial-attached downstream devices for unauthorized configuration changes. Vendor and third-party advisories to track for updated guidance and any new fixed versions: https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-os-command-injection-via-set-nfs-download and https://revrb.net/2026/09/21/revrb-lantern.html.

Affected VersionsENISA

SLCx-02 *
SLCx-03 *
SLB882 *
EMG8500 0 <9.7.0.1
SLC8000 0 <9.7.0.2
EMG7500 0 <9.7.0.1

Affected Packages

euvd emg7500 fix: 9.7.0.1
euvd emg8500 fix: 9.7.0.1
euvd slc8000 fix: 9.7.0.2

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 3 packages in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The affected devices are Lantronix out-of-band (OOB) management and serial console servers used to remotely administer network gear, servers and serial-attached devices; they expose a terminal/CLI management interface in addition to their web UI. The flaw is a classic OS command injection (CWE-78) in the CLI's 'set nfs download' routine, which is intended to let an administrator pull configuration or file content from an NFS server. Instead of validating or escaping the user-supplied parameter, the firmware concatenates it into a string handed to a system() call, so shell metacharacters supplied in the parameter are interpreted by the shell running with root privileges. Because the resulting command executes as root, an attacker with the 'services' permission can read or modify any file, alter firmware/configuration, and pivot toward devices managed through the unit's serial ports - reflected in the CVSS 4.0 scope-change metrics (SC:H/SI:H/SA:H) and our assessed CVSS 3.1 S:C rating. CPE coverage spans lantronix:slc8000, lantronix:emg8500, lantronix:emg7500, lantronix:slb882, lantronix:slcx-03 and lantronix:slcx-02, and both the CVSS 4.0 vector from the vendor/advisory data and our independent CVSS 3.1 assessment agree on network attack vector, low complexity and a high privilege requirement (PR:H), with no UI component.

Know when Slc8000 gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (VulnCheck) PRIMARY 9.4 CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
vuln.today AI 9.1 CRITICAL

Network CLI reachable with low complexity but requires the elevated 'services' permission (PR:H); root injection crosses scope to serial-attached downstream devices (S:C) with full triad loss.

3.1 AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

Primary rating from Vendor (VulnCheck).

CVSS VectorVendor: VulnCheck

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
High
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
High
Subsequent system: Integrity
High
Subsequent system: Availability
High

DescriptionCVE.org

Lantronix SLC8000 before firmware v9.7.0.3, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set nfs download command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.

Executive ViewAI

Why It Matters

A critical command injection flaw in Lantronix console servers (SLC8000, EMG8500, EMG7500, SLB882, SLCx-03, SLCx-02) allows an authenticated user with the 'services' permission to execute root-level commands, potentially compromising the device and any serial-attached infrastructure. Although no public exploit identified at time of analysis, these devices often provide out-of-band management access to critical network and server equipment, so a successful attack could disrupt operations and expose sensitive systems. Leadership should prioritize identifying and patching affected devices to mitigate downstream risk.

Business Impact: High
Compensating Controls

Apply vendor patch.

Threat Intelligence Overview

EPSS Score
2.5%
Top 16% exploitable
Prevalence
Low
niche vendor out-of-band console/serial server appliances, specialized infrastructure footprint
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 2.5%
Patch available Yes
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
No
Human Impact
High

Priority Score

50
Low Medium High Critical
KEV: 0
EPSS: +3
CVSS: +47
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

CVE-2026-80155 CRITICAL
10.0 Sep 22

Unauthenticated remote attackers can completely compromise the web management portal of Lantronix console servers, readi

CVE-2026-80144 CRITICAL
9.4 Sep 22

Authenticated command injection in Lantronix out-of-band console managers (SLC8000, EMG8500/EMG7500, SLB882, SLCx-03, SL

CVE-2026-80143 CRITICAL
9.4 Sep 22

Authenticated OS command injection in Lantronix out-of-band management appliances (SLC8000, EMG8500, EMG7500, SLB882, SL

CVE-2026-80152 CRITICAL
9.4 Sep 22

Authenticated command injection in Lantronix SLC8000 console servers (before firmware v9.7.0.3), EMG8500/EMG7500 (before

CVE-2026-80145 CRITICAL
9.4 Sep 22

Authenticated command injection in Lantronix console/out-of-band management appliances (SLC8000, EMG8500, EMG7500, SLB88

CVE-2026-80156 CRITICAL
9.4 Sep 22

Authenticated file-write path traversal in the Lantronix web management portal lets a logged-in attacker upload a crafte

CVE-2026-80147 CRITICAL
9.4 Sep 22

An authenticated stack-based buffer overflow in Lantronix SLC8000, EMG8500/EMG7500, SLB882 and SLCx-02/SLCx-03 console m

CVE-2026-80146 CRITICAL
9.4 Sep 22

Authenticated remote code execution in Lantronix SLC8000, EMG8500/EMG7500, SLB882, SLCx-03, and SLCx-02 console servers

CVE-2026-80154 HIGH
8.9 Sep 22

Predictable session-token generation in the web management portal of Lantronix SLC8000, EMG8500, EMG7500, SLB882, SLCx-0

CVE-2026-80150 HIGH
7.7 Sep 22

Server-side request forgery in the WebSSH/WebTelnet listener of Lantronix SLC8000 (before firmware 9.7.0.3), EMG8500/EMG

CVE-2026-80149 HIGH
7.7 Sep 22

Unauthenticated server-side request forgery in the Lantronix SLC8000, EMG8500/EMG7500 and SLB882 console servers lets an

CVE-2026-80148 HIGH
7.7 Sep 22

Unauthenticated server-side request forgery in the WebSSH/WebTelnet web terminal listener of Lantronix SLC8000 console s

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy