Skip to main content

Severity by source

Vendor (CERTVDE) PRIMARY
CRITICAL
qualitative
NVD
9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
vuln.today AI
9.8 CRITICAL

Unauthenticated network-reachable auth bypass via _account_log yields full admin control, so PR:N/UI:N/AC:L with high C/I/A; AV:N retained since interface is network-exposed.

3.1 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (CERTVDE).

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

3
Patch available
Sep 16, 2026 - 09:16 EUVD
Analysis Generated
Sep 16, 2026 - 08:18 vuln.today
CVE Published
Sep 16, 2026 - 07:48 cve.org
CRITICAL 9.8

DescriptionNVD

An unauthenticated remote attacker can exploit an authentication bypass in the _account_log function to log in as an admin, even when accounts are properly configured.

AnalysisAI

Authentication bypass in Pepperl+Fuchs ICE2/ICE3-series IO-Link masters (and OEM-equivalent Phoenix Contact IOL-MA8 modules) lets a remote unauthenticated attacker reach the _account_log function and authenticate as administrator, even on devices where accounts are correctly provisioned. The flaw grants full administrative control of the device management interface with no credentials. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
technique details hidden
Delivery
technique details hidden
Exploit
technique details hidden
Execution
technique details hidden
Impact
technique details hidden

Vulnerability AssessmentAI

Exploitation Exploitation requires only network reachability to the affected device's management interface (the _account_log function); per CVSS AV:N/AC:L/PR:N/UI:N there is no authentication, no user interaction, and no special configuration needed - the bypass works even when accounts are properly configured. … Additional conditions and limiting factors are described in the full assessment.
Risk Assessment The provided CVSS 3.1 vector (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, 9.8) is internally consistent with the description: no authentication, no user interaction, low complexity, and full compromise of the device. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario Full exploit scenario with step-by-step reproduction available after sign-in.
Remediation No specific fixed firmware version is present in the provided data; consult the CERT@VDE advisories (VDE-2026-014, VDE-2026-027, VDE-2026-028 at https://www.certvde.com/en/advisories/) for the vendor-released patched firmware and apply it to all affected ICE2/ICE3 and IOL-MA8 units. … Detailed patch versions, workarounds, and compensating controls in full report.

Recommended ActionAI

Within 24 hours: conduct a complete inventory of all Pepperl+Fuchs ICE2/ICE3 and Phoenix Contact IOL-MA8 deployments and identify which firmware versions are deployed; immediately restrict network access to these device management interfaces using firewall rules that limit connections to dedicated administrative workstations and engineering networks only. …

Sign in for detailed remediation steps and compensating controls.

Threat intelligence, references, and detailed analysis are available after sign-in.

CVE-2026-27565 CRITICAL
9.8 Sep 16

Root-level remote code execution affects Pepperl+Fuchs ICE2/ICE3-series and Phoenix Contact IOL-MA8 IO-Link master gatew

CVE-2026-27559 HIGH
8.8 Sep 16

Command injection in Pepperl+Fuchs ICE2/ICE3 and Phoenix Contact IOL MA8 series IO-Link Master devices allows a low-priv

CVE-2026-27558 HIGH
8.8 Sep 16

Command injection via a PHP web management endpoint on Pepperl+Fuchs ICE2/ICE3 series IO-Link Masters and Phoenix Contac

CVE-2026-27556 HIGH
8.8 Sep 16

Remote code execution is achievable on Pepperl+Fuchs ICE2/ICE3-series IO-Link Master devices and the Phoenix Contact IOL

CVE-2026-27555 HIGH
8.8 Sep 16

Remote code execution via PHP local file inclusion on Pepperl+Fuchs ICE2/ICE3 series IO-Link Master devices and OEM equi

CVE-2026-27554 HIGH
8.8 Sep 16

Command injection via the PHP-based IODD parameter save endpoint on Pepperl+Fuchs ICE2/ICE3 series IO-Link masters and O

CVE-2026-27551 HIGH
8.8 Sep 16

Command injection in Pepperl+Fuchs ICE2/ICE3 IO-Link Master devices (and OEM variants from Phoenix Contact and others) a

CVE-2026-27550 HIGH
8.8 Sep 16

Command injection via the Field_Shadow_Password class in Pepperl+Fuchs ICE2/ICE3 IO-Link master devices and Phoenix Cont

CVE-2026-27549 HIGH
8.8 Sep 16

Command injection in Pepperl+Fuchs ICE2/ICE3 series and Phoenix Contact IOL_MA8 IO-Link master devices enables an authen

CVE-2026-27548 HIGH
8.8 Sep 16

Command injection in Pepperl+Fuchs ICE2/ICE3 IO-Link Master devices and OEM equivalents allows a low-privileged authenti

CVE-2026-27547 HIGH
8.8 Sep 16

Command injection in Pepperl+Fuchs ICE2/ICE3 IO-Link Master devices (and OEM equivalents from Phoenix Contact and others

CVE-2026-27552 HIGH
8.1 Sep 16

Improper authorization on the IODD file upload endpoint of multiple Pepperl+Fuchs ICE2 and ICE3 IO-Link master devices,

Share

EUVD-2026-80229 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy