Skip to main content

DIAEnergie EUVDEUVD-2026-64760

| CVE-2026-78315 HIGH
SQL Injection (CWE-89)
2026-08-24 Deltaww GHSA-44c5-xccp-32vq
8.8
CVSS 3.1 · Vendor: Deltaww
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Obtain low-privilege DIAEnergie credential
  2. Delivery
    Send crafted HTTP request with SQL injection payload
  3. Exploit
    Manipulate backend database query execution
  4. Execution
    Invoke database-native OS command execution (e.g., xp_cmdshell)
  5. Impact
    Execute arbitrary code as database service account on server

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Parameterized queries, prepared statements
MITRE ATT&CK

2 techniques across 2 tactics: Initial Access, Persistence

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Exploitation requires possession of a valid low-privilege account on the DIAEnergie application, consistent with CVSS PR:L - unauthenticated exploitation is not indicated by available data. The attack is network-accessible (AV:N) over the DIAEnergie web interface and requires no additional user interaction beyond the attacker's own requests (UI:N). No special non-default application configuration is described as a prerequisite, meaning any standard DIAEnergie deployment running version 1.11.00.002 or earlier with a network-reachable interface is potentially vulnerable once a low-privilege credential is obtained. Exploitation is meaningfully limited by the credential requirement (PR:L) and by any network segmentation isolating the DIAEnergie server from untrusted networks; air-gapped or tightly segmented OT environments substantially reduce exploitability despite the network-vector classification.

Impact

The CVSS 3.1 vector AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H reflects a network-exploitable, low-complexity flaw requiring only a low-privilege credential, with full confidentiality, integrity, and availability impact - a score of 8.8 (High) is appropriate. No EPSS score is available in the provided data, and the CVE is absent from the CISA KEV catalog, so active exploitation is not confirmed. No POC code has been identified. The PR:L requirement raises the bar above fully unauthenticated attacks but does not substantially mitigate risk in targeted scenarios where default credentials, credential stuffing, or phishing can satisfy the prerequisite. The industrial (OT/ICS) deployment context amplifies real-world impact: RCE on an energy management server could disrupt visibility into energy systems or enable lateral movement into adjacent OT networks. The absence of EPSS data and KEV listing is a gap - prioritization should lean on the network-accessible RCE impact rather than exploitation probability signals, which are currently unavailable.

Exploit ScenarioDerived

An attacker who has obtained a low-privilege DIAEnergie account - via phishing, credential reuse, or default credentials - sends a crafted HTTP request with SQL injection payloads embedded in a vulnerable application parameter. The unsanitized input manipulates the backend SQL query, enabling stacked queries or abuse of database-native command execution features to run arbitrary operating system commands as the database service account. No public proof-of-concept code has been identified at time of analysis, but the technique is well-understood and widely documented for ICS/SCADA web applications using similar SQL backends.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.7% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Aug 24, 2026

SQL Injection in Delta Electronics DIAEnergie versions up to and including 1.11.00.002 enables a low-privileged remote attacker to achieve full remote code execution on the underlying server. Confirmed by vendor advisory Delta-PCSA-2026-00015 and ENISA EUVD-2026-64760, the flaw (CWE-89) stems from unsanitized user input passed directly to backend SQL queries, with the database engine serving as the execution bridge to the OS. No public exploit or CISA KEV listing has been identified at time of analysis, but the network-accessible RCE impact in an industrial energy management context elevates this to a high-priority remediation target.

RemediationAI

Consult Delta Electronics advisory Delta-PCSA-2026-00015 at https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00015_DIAEnergie%20SQL%20Injection%20Vulberabilities_v1.0.pdf for the vendor-released patch and exact fixed version number; a specific patched release version is not independently confirmed from the provided input data and should not be assumed. Where immediate patching is not feasible, the following specific compensating controls are recommended: restrict network access to the DIAEnergie web interface to authorized management VLANs or jump hosts only, eliminating exposure to untrusted networks and removing the AV:N exploitability condition; enforce strong, unique credentials for all DIAEnergie accounts and audit for default or shared credentials to raise the PR:L prerequisite; and harden the backend database by disabling dangerous stored procedures (e.g., xp_cmdshell on MSSQL) that allow SQL injection to escalate to OS command execution - note that disabling xp_cmdshell may affect legitimate DIAEnergie reporting or data export features and should be tested in a staging environment first. None of these mitigations eliminate the underlying SQLi flaw.

Affected VersionsENISA

DIAEnergie 0 ≤1.11.00.002

Affected Packages

euvd diaenergie no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

DIAEnergie is an industrial energy management system (EMS) developed by Delta Electronics (Deltaww), designed for monitoring and managing energy consumption in operational technology (OT) environments. The vulnerability is rooted in CWE-89 (Improper Neutralization of Special Elements Used in an SQL Command), where attacker-controlled input is incorporated into SQL queries without parameterization or adequate escaping. The CPE identifier cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:* covers all versions up to and including 1.11.00.002. In industrial EMS deployments, the backend database frequently runs with elevated privileges; SQL injection in this context commonly enables OS-level command execution via database-native mechanisms such as xp_cmdshell (Microsoft SQL Server) or user-defined functions (MySQL/MariaDB), which explains the direct escalation from SQLi to RCE described in the CVE.

Know when Diaenergie gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (Deltaww) PRIMARY 8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
vuln.today AI 8.8 HIGH

Network-accessible web interface justifies AV:N/AC:L; low-privilege credential required per exploitation conditions yields PR:L; RCE with full system access justifies C:H/I:H/A:H with no scope change.

3.1 AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (Deltaww).

CVSS VectorVendor: Deltaww

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionCVE.org

SQL Injection in Delta DIAEnergie v1.11.00.002 allows attacker to remote code execution.

Executive ViewAI

Why It Matters

Delta Electronics DIAEnergie energy management software (versions ≤1.11.00.002) contains a SQL injection vulnerability enabling remote code execution on industrial systems. This unpatched, network-accessible flaw in critical infrastructure software poses urgent risk to energy sector operations and requires immediate containment while awaiting vendor remediation.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations: enforce strict network segmentation isolating DIAEnergie infrastructure from untrusted networks, implement Web Application Firewall rules to detect and block SQL injection syntax, restrict database service account privileges to minimum required operations, enable comprehensive SQL query logging and alerting for anomalous execution patterns, and require authentication for all administrative interfaces.

Threat Intelligence Overview

EPSS Score
0.7%
Top 51% exploitable
Prevalence
Low
niche ICS energy management product, limited enterprise footprint
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.7%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Open
Automatable
No
Human Impact
High
Technical Impact
Total

Priority Score

45
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +44
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

SQL injection exploits the way applications construct database queries by mixing user input directly into SQL statements.

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

CVE-2024-4548 CRITICAL POC
9.8 May 06

An SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'Recalcula

CVE-2024-4547 CRITICAL POC
9.8 May 06

A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'Recalculat

CVE-2024-4549 HIGH POC
7.5 May 06

A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. Rated high severity (CV

CVE-2022-33005 MEDIUM POC
6.1 Jun 27

A cross-site scripting (XSS) vulnerability in the System Settings/IOT Settings module of Delta Electronics DIAEnergie v1

CVE-2026-78308 CRITICAL
9.8 Sep 24

Improper authentication in Delta Electronics DIAEnergie before 1.11.00.022 allows authentication bypass, enabling remote

CVE-2024-25574 CRITICAL
9.8 Apr 01

SQL injection vulnerability exists in GetDIAE_usListParameters. Rated critical severity (CVSS 9.8), this vulnerability i

CVE-2022-43775 CRITICAL
9.8 Oct 26

The HICT_Loop class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to ga

CVE-2022-43774 CRITICAL
9.8 Oct 26

The HandlerPageP_KID class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacke

CVE-2022-3214 CRITICAL
9.8 Sep 16

Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-c

CVE-2022-1378 CRITICAL
9.8 May 02

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p

CVE-2022-1377 CRITICAL
9.8 May 02

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_r

CVE-2022-1376 CRITICAL
9.8 May 02

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_p

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy