Skip to main content

Fh451 Firmware EUVDEUVD-2025-21237

| CVE-2025-7506 HIGH
Buffer Overflow (CWE-119)
2025-07-12 cna@vuldb.com
8.8
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, buffer size validation
MITRE ATT&CK

2 techniques across 2 tactics: Execution, Privilege Escalation

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

This vulnerability presents CRITICAL real-world risk despite authentication requirement. CVSS 8.8 with Network attack vector and Low complexity indicates ease of exploitation once authenticated. The CVSS vector (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) confirms high confidentiality, integrity, and availability impact. Critically, public POC availability and disclosed exploit status elevate exploitation probability significantly; this is NOT a theoretical high-CVSS issue but an actively weaponizable threat. Authentication requirement (PR:L) is minimal barrier given common router credential weaknesses (default credentials, password reuse). Stack overflow nature allows arbitrary code execution, making this a complete system compromise vector. For SSVC framework: exploitation is ACTIVE (POC public), automatable (no user interaction required), and technical impact is TOTAL (complete router takeover). Organizations managing Tenda FH451 devices should prioritize this as high-urgency.

Exploit ScenarioDerived

An attacker with network access to the Tenda FH451 device (either on the same LAN or via exposed WAN management interface if enabled) first authenticates using default credentials (Tenda FH451 common defaults: admin/admin) or leaked credentials. The attacker then crafts a malicious HTTP POST request to /goform/Natlimit with an oversized 'page' parameter containing shellcode or ROP gadgets. The stack buffer overflow in fromNatlimit() overwrites the return address, redirecting execution to attacker-controlled code. This achieves remote code execution with router privileges, allowing complete device compromise: exfiltration of network traffic, injection of malware into client connections, pivot to internal network, or denial of service. Public POC tools make this attack executable by non-sophisticated adversaries. Attack flow requires no user interaction or social engineering—only network-level access and valid credentials.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

CVE-2025-7506 is a critical stack-based buffer overflow vulnerability in Tenda FH451 router firmware version 1.0.0.9, exploitable via the HTTP POST parameter 'page' in the /goform/Natlimit endpoint. An authenticated remote attacker can achieve complete system compromise (code execution, data exfiltration, denial of service) without user interaction. Public exploit code is available, indicating active disclosure and likely exploitation in the wild.

RemediationAI

Immediate actions: (1) Identify all Tenda FH451 devices running firmware 1.0.0.9 in your network; (2) Check Tenda's official support page for firmware updates (typically available at support.tenda.com.cn or your regional Tenda support site); (3) If patched firmware is available (versions post-1.0.0.9), upgrade immediately via the device's web interface (Administration > Firmware Upgrade); (4) If no patch exists, implement compensating controls: restrict HTTP/HTTPS management interface access to trusted IP ranges only, disable remote management features if not essential, change default/weak credentials to strong random passwords, and consider isolating affected devices to a separate network segment. (5) Monitor device logs for suspicious POST requests to /goform/Natlimit endpoint. Patch availability status requires checking Tenda's official advisory; organizations should contact Tenda support directly for confirmed patch timelines.

Affected VersionsENISA

FH451 1.0.0.9

Affected Packages

euvd fh451 no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The vulnerability exists in the HTTP POST request handler for the /goform/Natlimit component, specifically in the fromNatlimit function. The root cause is classified as CWE-119 (Improper Restriction of Operations within the Bounds of a Memory Buffer), a classic stack-based buffer overflow where user-supplied input in the 'page' parameter is copied to a fixed-size stack buffer without proper bounds checking. This affects the Tenda FH451 wireless router (CPE: cpe:2.3:o:tenda:fh451_firmware:1.0.0.9:*:*:*:*:*:*:*), a consumer-grade networking device. The HTTP POST interface suggests the vulnerability is in the device's web management interface, likely implemented in C/C++ without memory-safe bounds validation.

Know when Fh451 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

2
PoC Detected
Jul 15, 2025 - 17:49 vuln.today
Public exploit code
CVE Published
Jul 12, 2025 - 23:15 nvd
HIGH 8.8

DescriptionCVE.org

A vulnerability classified as critical was found in Tenda FH451 1.0.0.9. Affected by this vulnerability is the function fromNatlimit of the file /goform/Natlimit of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Executive ViewAI

Why It Matters

A critical remote code execution vulnerability affects Tenda FH451 routers with no available patch, creating immediate risk for organizations relying on this device for network connectivity. With public exploit code circulating and an 8.8 CVSS score, attackers can compromise affected devices without authentication, potentially gaining control over network traffic and internal systems.

Business Impact: High
Compensating Controls

Disable HTTP access to the device management interface where possible; restrict administrative access to trusted IP ranges only; implement network segmentation to isolate affected devices; deploy WAF rules to block suspicious POST requests to /goform/Natlimit endpoint; monitor for exploitation attempts; disable the Natlimit feature if not required for operations; implement network intrusion detection signatures for this CVE; consider placing affected devices behind an additional security appliance or proxy.

Threat Intelligence Overview

EPSS Score
0.2%
Top 58% exploitable
Exploit
POC
Public exploit code exists
Data Quality
6 sources
Confidence: High

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC Yes
EPSS 0.2%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
No
Human Impact
High

Priority Score

64
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +44
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

CVE-2024-46048 CRITICAL POC
9.8 Sep 13

Tenda FH451 v1.0.0.9 has a command injection vulnerability in the formexeCommand function i. Rated critical severity (CV

CVE-2024-46046 CRITICAL POC
9.8 Sep 13

Tenda FH451 v1.0.0.9 has a stack overflow vulnerability located in the RouteStatic function. Rated critical severity (CV

CVE-2025-7434 HIGH POC
8.8 Jul 11

CVE-2025-7434 is a critical stack-based buffer overflow vulnerability in Tenda FH451 wireless routers (versions up to 1.

CVE-2025-7505 HIGH POC
8.8 Jul 12

CVE-2025-7505 is a critical stack-based buffer overflow vulnerability in Tenda FH451 v1.0.0.9 affecting the HTTP POST re

CVE-2026-2911 HIGH POC
8.8 Feb 22

Buffer overflow in Tenda FH451 firmware versions up to 1.0.0.9 allows authenticated remote attackers to achieve code exe

CVE-2026-3677 HIGH POC
8.8 Mar 07

Stack overflow in Tenda FH451 firmware's setcfm function allows authenticated remote attackers to achieve complete syste

CVE-2026-3678 HIGH POC
8.8 Mar 07

Remote code execution in Tenda FH451 firmware via stack-based buffer overflow in the WAN configuration endpoint allows u

CVE-2024-46047 HIGH POC
7.5 Sep 13

Tenda FH451 v1.0.0.9 has a stack overflow vulnerability in the fromDhcpListClient function. Rated high severity (CVSS 7.

CVE-2025-44176 MEDIUM POC
6.5 May 12

Tenda FH451 V1.0.0.9 is vulnerable to Remote Code Execution in the formSafeEmailFilter function. Rated medium severity (

CVE-2025-45514 MEDIUM POC
6.5 May 07

Tenda FH451 V1.0.0.9 has a stack overflow vulnerability in the function.frmL7ImForm. Rated medium severity (CVSS 6.5), t

CVE-2024-12002 MEDIUM POC
5.3 Nov 30

A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Rated medi

CVE-2025-5080 HIGH POC
8.7 May 22

A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Rated high severity (CVSS 8.7), this vulne

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy