Fh451 Firmware
CVE-2025-5080
HIGH
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
Lifecycle Timeline
3DescriptionCVE.org
A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function webExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
AnalysisAI
A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified as Buffer Overflow (CWE-119), which allows attackers to corrupt memory to execute arbitrary code or crash the application. A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function webExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Affected products include: Tenda Fh451 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use memory-safe languages or bounds-checking. Enable ASLR, DEP/NX, stack canaries. Use safe string functions.
More in Fh451 Firmware
View allTenda FH451 v1.0.0.9 has a command injection vulnerability in the formexeCommand function i. Rated critical severity (CV
Tenda FH451 v1.0.0.9 has a stack overflow vulnerability located in the RouteStatic function. Rated critical severity (CV
CVE-2025-7434 is a critical stack-based buffer overflow vulnerability in Tenda FH451 wireless routers (versions up to 1.
CVE-2025-7506 is a critical stack-based buffer overflow vulnerability in Tenda FH451 router firmware version 1.0.0.9, ex
CVE-2025-7505 is a critical stack-based buffer overflow vulnerability in Tenda FH451 v1.0.0.9 affecting the HTTP POST re
Buffer overflow in Tenda FH451 firmware versions up to 1.0.0.9 allows authenticated remote attackers to achieve code exe
Stack overflow in Tenda FH451 firmware's setcfm function allows authenticated remote attackers to achieve complete syste
Remote code execution in Tenda FH451 firmware via stack-based buffer overflow in the WAN configuration endpoint allows u
Tenda FH451 v1.0.0.9 has a stack overflow vulnerability in the fromDhcpListClient function. Rated high severity (CVSS 7.
Tenda FH451 V1.0.0.9 is vulnerable to Remote Code Execution in the formSafeEmailFilter function. Rated medium severity (
Tenda FH451 V1.0.0.9 has a stack overflow vulnerability in the function.frmL7ImForm. Rated medium severity (CVSS 6.5), t
A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Rated medi
Same weakness CWE-119 – Buffer Overflow
View allSame technique Buffer Overflow
View allShare
External POC / Exploit Code
Leaving vuln.today