Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
3DescriptionCVE.org
A vulnerability classified as critical has been found in TOTOLINK X15 1.0.0-B20230714.1105. This affects an unknown part of the file /boafrm/formSaveConfig of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
AnalysisAI
A critical buffer overflow vulnerability exists in TOTOLINK X15 firmware version 1.0.0-B20230714.1105, affecting the HTTP POST request handler in the /boafrm/formSaveConfig endpoint. An authenticated attacker can exploit the unsanitized 'submit-url' parameter to trigger a buffer overflow, potentially achieving remote code execution with full system compromise (confidentiality, integrity, and availability impact). The vulnerability has been publicly disclosed with exploit proof-of-concept available, creating immediate real-world risk.
Technical ContextAI
This vulnerability resides in the HTTP POST request handling mechanism of TOTOLINK X15 router firmware, specifically within the /boafrm/formSaveConfig component. The root cause is classified as CWE-119 (Improper Restriction of Operations within the Bounds of a Memory Buffer), a classic buffer overflow weakness. The 'submit-url' parameter lacks proper input validation and buffer boundary checks, allowing an attacker to write beyond allocated memory regions. The affected component processes user-supplied configuration data without adequate length validation, enabling stack or heap corruption depending on the memory layout. The vulnerability affects TOTOLINK X15 devices running firmware build B20230714.1105, which likely represents a residential Wi-Fi router or mesh system commonly deployed in home and small business networks.
More in X15 Firmware
View allA buffer overflow vulnerability (CVSS 8.8). Risk factors: public PoC available.
Critical buffer overflow vulnerability in TOTOLINK X15 firmware (version 1.0.0-B20230714.1105) affecting the HTTP POST r
Critical remote buffer overflow vulnerability in TOTOLINK X15 router firmware (version 1.0.0-B20230714.1105) affecting t
A buffer overflow vulnerability in A vulnerability (CVSS 8.8). Risk factors: public PoC available.
A vulnerability classified as critical has been found in TOTOLINK X15 up to 1.0.0-B20230714.1105. Affected is an unknown
CVE-2025-6399 is a critical buffer overflow vulnerability in TOTOLINK X15 router (firmware version 1.0.0-B20230714.1105)
CVE-2025-6402 is a critical buffer overflow vulnerability in TOTOLINK X15 firmware version 1.0.0-B20230714.1105 affectin
A vulnerability, which was classified as critical, has been found in TOTOLINK X15 1.0.0-B20230714.1105. Affected by this
Critical buffer overflow vulnerability in TOTOLINK X15 firmware version 1.0.0-B20230714.1105 affecting the HTTP POST req
Critical buffer overflow vulnerability in TOTOLINK X15 router firmware version 1.0.0-B20230714.1105, affecting the HTTP
Critical buffer overflow vulnerability in TOTOLINK X15 firmware version 1.0.0-B20230714.1105 affecting the HTTP POST req
Critical buffer overflow vulnerability in TOTOLINK X15 1.0.0-B20230714.1105 affecting the DMZ configuration HTTP POST ha
Same weakness CWE-119 – Buffer Overflow
View allSame technique Buffer Overflow
View allShare
External POC / Exploit Code
Leaving vuln.today
EUVD-2025-17104