Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessAttacker hosts crafted HTML page
-
DeliveryPhish or lure MPMS user to visit page
-
ExploitBrowser silently sends malformed cross-origin request to MPMS
-
ExecutionServer fails origin verification (CWE-940)
-
PersistArbitrary OS commands execute server-side
-
ImpactFull confidentiality, integrity, availability compromise
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V12 - Secure Communication Communication channel verification
|
| Exploitation Conditions | Exploitation requires that a user with an active or credentialed session on the Le-yan Medical Practice Management System open an attacker-crafted HTML page in their browser; the CVSS 4.0 UI:A metric confirms this interaction is mandatory and the attack cannot be automated against passive targets. The MPMS server must be network-reachable from the browser executing the crafted page - whether via internet exposure or internal network depending on deployment. No special non-default server configuration is stated as required. Limiting factors: the mandatory user interaction step means the attacker must succeed at social engineering (phishing, malicious ad, typosquatting) before exploitation is possible; if the MPMS is restricted to an isolated intranet, the attacker's ability to reach both the victim and the server simultaneously is constrained. The exact authentication level of the required victim session is not explicitly stated in the available description, and cannot be confirmed from the current data. |
| Impact | The CVSS 4.0 base score of 8.6 (AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H) reflects high severity with complete compromise of the vulnerable system achievable. The most meaningful real-world moderating factor is UI:A - exploitation is not fully automated and requires an attacker to successfully social-engineer a legitimate system user into opening a crafted page. No EPSS data was provided in the available intelligence, no CISA KEV listing exists, and no public POC has been identified, collectively suggesting no confirmed widespread active exploitation at time of analysis. However, the medical context materially elevates downstream consequences: OS-level compromise of a medical practice management system likely exposes protected health information (PHI), patient records, and billing data, triggering regulatory obligations beyond typical breach scenarios. The wildcard CPE version string means no safe floor version is identifiable - all deployed instances should be considered vulnerable. EPSS and exploit maturity data are absent, which limits confidence in exploitation probability. |
| Exploit ScenarioDerived | An attacker registers a domain and hosts a webpage containing crafted HTML or JavaScript that, when loaded by a user with an active Le-yan MPMS session, silently submits a malformed request to the MPMS server. Because the server does not verify the origin of the communication channel (CWE-940), it treats the cross-origin request as legitimate and executes the embedded OS command payload with the application's process privileges. The attacker - who holds no credentials - achieves full remote code execution on the server through the victim's browser as the sole intermediary. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv2 – Aug 25, 2026
Remote code execution in Le-yan's Medical Practice Management System allows unauthenticated remote attackers to execute arbitrary OS commands on the server by inducing a user to visit a crafted HTML page. The root cause is CWE-940 (Improper Verification of Source of a Communication Channel), indicating the application processes incoming requests without validating their origin - a pattern consistent with CSRF-driven command injection where the server's trust of unverified channels is the enabling weakness. No public exploit code has been identified and no CISA KEV listing is present, but the CVSS 4.0 score of 8.6 with full confidentiality, integrity, and availability impact on the vulnerable system reflects high severity with significant consequences in a healthcare data context.
Earlier versions of this analysis (1)
Remote code execution in Le-yan's Medical Practice Management System allows unauthenticated remote attackers to execute arbitrary OS commands by enticing a target user to visit a crafted HTML page. The vulnerability stems from CWE-940 (Improper Verification of Source of a Communication Channel), meaning the server does not properly validate the origin of incoming requests, enabling cross-site-style command injection against the underlying OS. No public exploit code or CISA KEV listing has been identified at time of analysis, but full CIA impact (C:H/I:H/A:H) places this at CVSS 8.8 - a serious risk for any clinic or medical practice running the software.
RemediationAI
No specific patched version has been identified from the TWCERT advisories (https://www.twcert.org.tw/en/cp-139-11128-8bd30-2.html); contact Le-yan directly to obtain a patched release and apply it immediately upon availability. Until a vendor patch is confirmed, restrict network access to the MPMS server to a trusted internal network or VPN - this eliminates the ability of external attackers to reach the server even if a user is socially engineered, and is the single most impactful compensating control given the CSRF-like attack model. Deploy a web application firewall configured to enforce strict origin and referer header validation on state-changing requests, which can block cross-origin exploitation at the perimeter without modifying the application. Ensure users who access the MPMS do not simultaneously browse untrusted external websites in the same browser session; browser isolation or dedicated terminals for MPMS access would further reduce CSRF exposure. Monitor server-side process logs for anomalous child process spawning or unexpected OS command execution.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The affected product is Le-yan Medical Practice Management System, covering all versions per CPE cpe:2.3:a:le-yan:medical_practice_management_system:*:*:*:*:*:*:*:* with no lower or upper version bound identified. The root cause class is CWE-940 - Improper Verification of Source of a Communication Channel - meaning the server processes requests without adequately confirming the legitimacy or origin of the communication. When combined with the CVSS 4.0 UI:A (active user interaction) metric, the attack model is consistent with a cross-site request forgery-enabled command injection: an attacker-controlled HTML page, when loaded in a victim's browser, issues crafted requests to the MPMS server, which the server executes as OS commands because it cannot distinguish legitimate in-application requests from externally sourced ones. This is an architectural trust boundary failure rather than a simple input sanitization issue.
Know when Medical Practice Management System gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Network-delivered, low-complexity attack requiring no attacker privileges but mandatory victim interaction per CWE-940 CSRF pattern; no scope change; full CIA impact from arbitrary OS command execution.
Primary rating from Vendor (twcert).
CVSS VectorVendor: twcert
Lifecycle Timeline
2DescriptionCVE.org
Medical Practice Management System developed by Le-yan has a Remote Code Execution vulnerability. Unauthenticated remote attackers can execute arbitrary OS commamnds via a crafted HTML page.
Executive ViewAI
Le-yan's Medical Practice Management System contains an unauthenticated remote code execution vulnerability (CVE-2026-78685) that allows attackers to execute arbitrary commands on servers containing patient medical records and operational data. This directly exposes any healthcare organization using this system to unauthorized access to protected health information, system compromise, and operational disruption-triggering immediate compliance risk under HIPAA and state privacy laws. No patch is currently available, requiring urgent containment measures and contingency planning.
No vendor-released patch identified at time of analysis. Interim mitigations include: network isolation of affected systems from general infrastructure to prevent lateral movement; Web Application Firewall rules to block malicious HTML-based payloads targeting the application; restriction of user access credentials to essential clinical personnel only; implementation of multi-factor authentication where supported; continuous monitoring for unexpected process execution, system modification, and network connections; and full logging retention for at least 90 days to support forensic investigation if compromise is suspected. These controls reduce risk but do not eliminate it; vendor patch deployment or system replacement is the definitive remediation.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.
EUVD-2026-65270
GHSA-79cf-7rfq-5q6f
NVD
CVE.org
EPSS
Vulnrichment
Exploit-DB