Skip to main content
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Obtain valid admin credentials
  2. Delivery
    Access VigorSwitch web management interface
  3. Exploit
    Submit crafted setDevice request with injected shell payload
  4. Execution
    Unsanitized input passed to OS command executor
  5. Impact
    Execute arbitrary commands as root on switch firmware

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization OS command sanitization, avoid shell exec
MITRE ATT&CK

2 techniques across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Exploitation requires valid administrative credentials for the device's web management interface - the CVSS PR:H metric confirms this is a high-privilege prerequisite, not an unauthenticated path. The attack is delivered over the network (AV:N) to the HTTP/HTTPS management port, meaning the management interface must be reachable from the attacker's location. No special non-default configuration is required beyond the management interface being accessible and admin credentials being known. What limits exploitation: (1) admin credentials must be compromised or known in advance; (2) the management interface must be network-reachable from the attacker - organizations that isolate management interfaces to out-of-band VLANs substantially reduce exposure; (3) no user interaction is required once credentials are obtained, meaning exploitation is otherwise straightforward. There is no requirement for a specific firmware version to be running based on available CPE data.

Impact

The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H) scores 8.6, reflecting network reachability and full system-level impact, tempered significantly by the PR:H requirement - valid administrative credentials are a hard prerequisite. This substantially reduces opportunistic exploitation risk compared to unauthenticated vulnerabilities: an attacker must first compromise or possess admin-level access to the device's web interface before this vulnerability is relevant. There is no CISA KEV listing and no EPSS score was provided in the source data, so exploitation probability cannot be quantified numerically. No public proof-of-concept code has been identified. The realistic threat model centers on attackers who have already obtained admin credentials through phishing, credential stuffing, or lateral movement - at that point this vulnerability provides a reliable path to root-level device control. The wide model range (28+ SKUs) means that organizations running heterogeneous DrayTek switching infrastructure face a broad remediation scope. The absence of a scope change (SC:N/SI:N/SA:N) bounds the impact to the switch device itself rather than downstream network segments, but a compromised managed switch is still a high-value position for traffic interception or network reconfiguration.

Exploit ScenarioDerived

An attacker who has obtained valid administrative credentials - through phishing, password reuse, or prior network compromise - authenticates to the VigorSwitch web management interface over the network. They submit a crafted configuration request to the setDevice function with a payload embedded in the username, password, or location field (e.g., a shell metacharacter sequence such as a semicolon or backtick followed by an arbitrary command). The device's backend processes this unsanitized input, executing the injected command as root, giving the attacker full control of the switch's operating system.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
Patch available 1.7% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Aug 24, 2026

Command injection via the setDevice function affects multiple DrayTek VigorSwitch managed switch models, allowing an authenticated remote administrator to execute arbitrary OS commands with root privileges by supplying unsanitized input in the username, password, or location fields. The breadth of affected hardware - at least 28 distinct VigorSwitch SKUs spanning G, P, PQ, Q, and FX series - substantially widens the organizational exposure surface. No public exploit code or CISA KEV listing has been identified at time of analysis, but the network-accessible management interface and high-impact outcome make this a meaningful post-compromise escalation path.

RemediationAI

The primary remediation is to apply the patched firmware released by DrayTek, details of which are available in the vendor security advisory at https://www.draytek.com/about/security-advisory/multiple-vulnerabilities-in-vigorswitch-series-august-2026/. An exact fixed firmware version was not independently confirmed in the available source data, so administrators should consult that advisory directly for model-specific upgrade instructions. As an immediate compensating control, restrict access to the web management interface to a dedicated out-of-band management VLAN and deny access from general user or production networks - this does not eliminate the vulnerability but significantly reduces the attack surface to hosts that legitimately require administrative access. Additionally, enforce multi-factor authentication on any VPN or jump-host used to reach the management interface, and rotate all administrative credentials on affected devices. Disabling the web management interface entirely in favor of CLI-only access (if supported by the model) removes the HTTP attack surface but may impact operational workflows. Do not expose the management interface directly to the internet.

Affected VersionsENISA

VigorSwitch P2540x 0 <2.9.10
VigorSwitch FX2120 0 <3.9.10
VigorSwitch G2540xs 0 <3.9.10
VigorSwitch G2280x 0 <2.9.10
VigorSwitch P2121 0 <2.9.10
VigorSwitch G1280 0 <2.9.10
VigorSwitch Q2300x 0 <2.10.7
VigorSwitch P1281x 0 <2.9.10
VigorSwitch P2540xs 0 <3.9.10
VigorSwitch G1282 0 <2.9.10
VigorSwitch PQ2121x 0 <2.9.10
VigorSwitch PX2060 0 <2.9.10
VigorSwitch G2282x 0 <2.10.6
VigorSwitch P1282 0 <2.9.10
VigorSwitch P2280x 0 <2.9.10
VigorSwitch G2121 0 <2.9.10
VigorSwitch P1280 0 <2.9.10
VigorSwitch G2542x 0 <3.10.6
VigorSwitch G2100 0 <2.9.10
VigorSwitch P2542xh 0 <3.10.6
VigorSwitch P2100 0 <2.9.10
VigorSwitch G2540x 0 <2.9.10
VigorSwitch PQ2300xb 0 <2.10.7
VigorSwitch P2542x 0 <3.10.6
VigorSwitch P2282x 0 <2.10.6
VigorSwitch Q2121x 0 <2.9.10
VigorSwitch Q2200x 0 <2.9.10
VigorSwitch PQ2200xb 0 <2.9.10

Affected Packages

euvd vigorswitch_fx2120 fix: 3.9.10
euvd vigorswitch_g1280 fix: 2.9.10
euvd vigorswitch_g1282 fix: 2.9.10
euvd vigorswitch_g2100 fix: 2.9.10
euvd vigorswitch_g2121 fix: 2.9.10
euvd vigorswitch_g2280x fix: 2.9.10
euvd vigorswitch_g2282x fix: 2.10.6
euvd vigorswitch_g2540x fix: 2.9.10
euvd vigorswitch_g2540xs fix: 3.9.10
euvd vigorswitch_g2542x fix: 3.10.6
euvd vigorswitch_p1280 fix: 2.9.10
euvd vigorswitch_p1281x fix: 2.9.10
euvd vigorswitch_p1282 fix: 2.9.10
euvd vigorswitch_p2100 fix: 2.9.10
euvd vigorswitch_p2121 fix: 2.9.10
euvd vigorswitch_p2280x fix: 2.9.10
euvd vigorswitch_p2282x fix: 2.10.6
euvd vigorswitch_p2540x fix: 2.9.10
euvd vigorswitch_p2540xs fix: 3.9.10
euvd vigorswitch_p2542x fix: 3.10.6
euvd vigorswitch_p2542xh fix: 3.10.6
euvd vigorswitch_pq2121x fix: 2.9.10
euvd vigorswitch_pq2200xb fix: 2.9.10
euvd vigorswitch_pq2300xb fix: 2.10.7
euvd vigorswitch_px2060 fix: 2.9.10
euvd vigorswitch_q2121x fix: 2.9.10
euvd vigorswitch_q2200x fix: 2.9.10
euvd vigorswitch_q2300x fix: 2.10.7

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 28 packages in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The vulnerability is rooted in CWE-78 (Improper Neutralization of Special Elements used in an OS Command), a classic OS command injection pattern where attacker-controlled string values are concatenated into a shell command without proper escaping or allowlisting. The affected function, setDevice, processes device configuration fields - username, password, and location - and passes them to underlying OS-level command execution without sanitization. CPE data confirms the affected vendor as DrayTek Corporation across the VigorSwitch product line (cpe:2.3:a:draytek_corporation:vigorswitch_*). DrayTek VigorSwitch devices run embedded Linux firmware and expose a web-based management interface; the setDevice function is part of that interface's configuration backend. Because the injected command executes with root privileges, the full firmware environment is compromised on successful exploitation.

Know when Vigorswitch G2540Xs gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (VulnCheck) PRIMARY 8.6 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
vuln.today AI 7.2 HIGH

Network delivery and no user interaction confirmed; PR:H because admin credentials are explicitly required; no scope change as impact is bounded to the switch itself.

3.1 AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (VulnCheck).

CVSS VectorVendor: VulnCheck

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
High
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

2
Patch available
Aug 24, 2026 - 18:02 EUVD
CVE Published
Aug 24, 2026 - 17:07 cve.org
HIGH 8.6

DescriptionCVE.org

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setDevice function. The vulnerability is caused by insufficient sanitization of the username, password, and location fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface.

Executive ViewAI

Why It Matters

DrayTek VigorSwitch managed switches across 28+ models can be compromised at the administrator level to allow complete network infrastructure takeover, creating a critical post-compromise escalation risk for organizations. No public exploit code has been identified at time of analysis, but the severity of potential impact warrants immediate action. Without vendor patches currently available, organizations must implement interim security controls to mitigate this exposure.

Business Impact: High
Compensating Controls

Restrict management interface access to trusted administrative subnets via firewall; implement multi-factor authentication for all administrative accounts; disable remote management where operationally feasible; enable detailed logging and monitoring of administrative operations; conduct quarterly reviews of administrative privileges; maintain isolated lab environment for rapid patch testing and deployment.

Threat Intelligence Overview

EPSS Score
1.7%
Top 25% exploitable
Prevalence
Medium
SMB/enterprise managed switch vendor, broad in certain regions
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 1.7%
Patch available Yes
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
No
Human Impact
High

Priority Score

45
Low Medium High Critical
KEV: 0
EPSS: +2
CVSS: +43
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

CVE-2026-71921 CRITICAL
9.3 Aug 24

Pre-authentication OS command injection in DrayTek VigorSwitch managed switches lets a remote, unauthenticated attacker

CVE-2026-71943 HIGH
8.6 Aug 24

Command injection in DrayTek VigorSwitch's setDevNet function allows authenticated remote attackers to execute arbitrary

CVE-2026-71930 HIGH
8.6 Aug 24

Command injection in DrayTek VigorSwitch's setTime function enables authenticated administrators to execute arbitrary OS

CVE-2026-71929 HIGH
8.6 Aug 24

Command injection in multiple DrayTek VigorSwitch models enables authenticated administrators to execute arbitrary OS co

CVE-2026-71925 HIGH
8.6 Aug 24

Command injection in multiple DrayTek VigorSwitch models' getDetail function enables authenticated remote attackers hold

CVE-2026-71924 HIGH
8.6 Aug 24

Command injection in DrayTek VigorSwitch's getVid function allows an authenticated remote administrator to execute arbit

CVE-2026-71919 HIGH
8.6 Aug 24

Command injection in multiple DrayTek VigorSwitch managed switch models allows an authenticated remote administrator to

CVE-2026-71918 HIGH
8.6 Aug 24

Command injection in the DrayTek VigorSwitch `webBackupAction` function allows authenticated remote attackers to execute

CVE-2026-71917 HIGH
8.6 Aug 24

Command injection in the DrayTek VigorSwitch series' pingtrace diagnostic function allows an authenticated administrator

CVE-2026-71915 HIGH
8.6 Aug 24

Command injection in DrayTek VigorSwitch's jsonstatus function allows authenticated remote administrators to execute arb

CVE-2026-71931 HIGH
8.6 Aug 24

Command injection in DrayTek VigorSwitch's tftp_upgrade function enables authenticated remote administrators to execute

CVE-2026-71916 HIGH
8.6 Aug 24

Command injection via the commandTable function affects 28 DrayTek VigorSwitch managed switch models across multiple fir

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy