Skip to main content
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Obtain admin credentials via phishing or credential reuse
  2. Delivery
    Access VigorSwitch web management interface
  3. Exploit
    Send crafted HTTP request to webBackupAction function
  4. Execution
    Inject shell metacharacters into unsanitized parameter fields
  5. Persist
    Execute arbitrary OS commands as root
  6. Impact
    Exfiltrate configuration or persist backdoor access

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization OS command sanitization, avoid shell exec
MITRE ATT&CK

2 techniques across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Exploitation requires possession of valid administrative credentials for the DrayTek VigorSwitch web management interface, confirmed by CVSS PR:H. The attacker must have network-layer connectivity to the management interface - typically TCP port 443 or 80 depending on configuration. The vulnerable webBackupAction function is reachable via the standard web management portal; no non-default feature enablement beyond default web management access is described as required. Limiting factors: (1) administrative credential possession is mandatory - CVSS PR:H explicitly excludes unauthenticated exploitation; (2) network access to the management interface is required, which is typically restricted to management VLANs in well-segmented environments; (3) exploitation is specific to unpatched firmware versions across the affected model list. The administrative credential requirement substantially limits opportunistic internet-scale exploitation but does not mitigate insider threats, credential compromise scenarios, or environments where management interfaces are accessible from general user network segments.

Impact

The CVSS 4.0 score of 8.6 accurately reflects the high C/I/A impact of root-level command execution on a managed network switch, which sits at a position of significant trust within enterprise and SMB topologies. The PR:H requirement (administrative credentials) is the principal constraint against mass exploitation and meaningfully separates this from critical unauthenticated network vulnerabilities. However, managed switch admin portals are frequently accessible from internal networks without strict access segmentation, and credential reuse, phishing of administrators, or insider threats represent realistic pre-exploitation paths. No KEV listing is present and no EPSS score was provided, which limits automated threat-signal prioritization; active exploitation is unconfirmed. The breadth of affected models - 28 or more VigorSwitch SKUs spanning the entire product line - amplifies aggregate organizational risk: any environment running multiple DrayTek switches faces compounded exposure, and a single compromised admin credential could affect every unpatched device on the management network. The absence of CVSS scope change metrics (SC:N/SI:N/SA:N) reflects single-device impact per the scoring framework, but lateral movement and pivot opportunities through a compromised network switch are operationally significant factors not captured in the base score.

Exploit ScenarioDerived

An attacker who has acquired valid administrative credentials for a DrayTek VigorSwitch web management interface - through phishing, credential reuse from a previously compromised device, or internal network access - sends a crafted HTTP request to the webBackupAction endpoint with OS command payloads embedded in parameters such as option or valueN. The switch's web backend passes these unsanitized values directly to a shell command, executing the injected payload as root and granting the attacker full control of the device OS. No public exploit code has been identified at time of analysis, but the attack technique is consistent with well-documented OS command injection patterns and requires low technical sophistication once credentials are in hand.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
Patch available 3.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Aug 24, 2026

Command injection in the DrayTek VigorSwitch webBackupAction function allows authenticated remote attackers to execute arbitrary OS commands with root privileges across more than 25 managed switch models. Insufficient input sanitization of the option, key, pw_encode, pathN, and valueN parameters enables shell metacharacter injection, resulting in full device compromise. No public exploit has been identified at time of analysis; the administrative credential prerequisite is the primary barrier against opportunistic exploitation.

RemediationAI

Apply vendor-released firmware patches for each affected VigorSwitch model as detailed in DrayTek's August 2026 security advisory at https://www.draytek.com/about/security-advisory/multiple-vulnerabilities-in-vigorswitch-series-august-2026/; exact patched firmware version numbers per model are listed there and not independently confirmed in available data. As an immediate compensating control before patching, restrict network access to the web management interface to a dedicated management VLAN or specific trusted IP ranges using upstream firewall ACLs - this eliminates network reachability for unauthorized parties without requiring device changes. If local console access is available and remote web management is non-essential, disabling the web management interface entirely removes the network attack surface with no functional trade-off for locally-managed environments. Rotating administrative credentials reduces risk from pre-compromised accounts but does not remediate the underlying injection flaw. Enabling management interface access logging aids in detecting exploitation attempts. Note that restricting management interface network access may interrupt legitimate remote administration workflows and should be coordinated with network operations teams.

Affected VersionsENISA

VigorSwitch PQ2300xb 0 <2.10.7
VigorSwitch G2540xs 0 <3.9.10
VigorSwitch P1281x 0 <2.9.10
VigorSwitch P2542xh 0 <3.10.6
VigorSwitch PQ2200xb 0 <2.9.10
VigorSwitch G1282 0 <2.9.10
VigorSwitch G2280x 0 <2.9.10
VigorSwitch Q2121x 0 <2.9.10
VigorSwitch P2542x 0 <3.10.6
VigorSwitch Q2300x 0 <2.10.7
VigorSwitch PQ2121x 0 <2.9.10
VigorSwitch P2540xs 0 <3.9.10
VigorSwitch P2121 0 <2.9.10
VigorSwitch G2100 0 <2.9.10
VigorSwitch P2282x 0 <2.10.6
VigorSwitch FX2120 0 <3.9.10
VigorSwitch G2540x 0 <2.9.10
VigorSwitch P1282 0 <2.9.10
VigorSwitch G2121 0 <2.9.10
VigorSwitch PX2060 0 <2.9.10
VigorSwitch G2282x 0 <2.10.6
VigorSwitch G1280 0 <2.9.10
VigorSwitch P2100 0 <2.9.10
VigorSwitch P1280 0 <2.9.10
VigorSwitch G2542x 0 <3.10.6
VigorSwitch Q2200x 0 <2.9.10
VigorSwitch P2540x 0 <2.9.10
VigorSwitch P2280x 0 <2.9.10

Affected Packages

euvd vigorswitch_fx2120 fix: 3.9.10
euvd vigorswitch_g1280 fix: 2.9.10
euvd vigorswitch_g1282 fix: 2.9.10
euvd vigorswitch_g2100 fix: 2.9.10
euvd vigorswitch_g2121 fix: 2.9.10
euvd vigorswitch_g2280x fix: 2.9.10
euvd vigorswitch_g2282x fix: 2.10.6
euvd vigorswitch_g2540x fix: 2.9.10
euvd vigorswitch_g2540xs fix: 3.9.10
euvd vigorswitch_g2542x fix: 3.10.6
euvd vigorswitch_p1280 fix: 2.9.10
euvd vigorswitch_p1281x fix: 2.9.10
euvd vigorswitch_p1282 fix: 2.9.10
euvd vigorswitch_p2100 fix: 2.9.10
euvd vigorswitch_p2121 fix: 2.9.10
euvd vigorswitch_p2280x fix: 2.9.10
euvd vigorswitch_p2282x fix: 2.10.6
euvd vigorswitch_p2540x fix: 2.9.10
euvd vigorswitch_p2540xs fix: 3.9.10
euvd vigorswitch_p2542x fix: 3.10.6
euvd vigorswitch_p2542xh fix: 3.10.6
euvd vigorswitch_pq2121x fix: 2.9.10
euvd vigorswitch_pq2200xb fix: 2.9.10
euvd vigorswitch_pq2300xb fix: 2.10.7
euvd vigorswitch_px2060 fix: 2.9.10
euvd vigorswitch_q2121x fix: 2.9.10
euvd vigorswitch_q2200x fix: 2.9.10
euvd vigorswitch_q2300x fix: 2.10.7

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 28 packages in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The vulnerability resides in the webBackupAction function of the DrayTek VigorSwitch web management interface. CWE-78 (Improper Neutralization of Special Elements Used in an OS Command) identifies the root cause: user-supplied input in multiple backup-related parameters is concatenated into OS-level shell commands without adequate escaping or allowlist validation. This permits injection of shell metacharacters (semicolons, pipes, backticks, subshell constructs) that the underlying Linux-based switch OS interprets as additional commands. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H) confirms network-accessible exploitation requiring only high-privilege administrative credentials, with no attack complexity or timing dependency. Injected commands execute as root, granting complete control over the switch operating system, including configuration, routing tables, ACLs, and credentials stored on-device.

Know when Vigorswitch G2540Xs gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (VulnCheck) PRIMARY 8.6 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
vuln.today AI 7.2 HIGH

Network-accessible web interface requires administrative credentials (PR:H); root-level command execution yields high C/I/A with no scope change beyond the compromised device.

3.1 AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (VulnCheck).

CVSS VectorVendor: VulnCheck

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
High
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

2
Patch available
Aug 24, 2026 - 18:02 EUVD
CVE Published
Aug 24, 2026 - 17:07 cve.org
HIGH 8.6

DescriptionCVE.org

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the webBackupAction function. The vulnerability is caused by insufficient filtering of the option, key, pw_encode, pathN, and valueN fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface.

Executive ViewAI

Why It Matters

DrayTek VigorSwitch devices across 25+ managed models contain a command injection vulnerability in the webBackupAction function that allows authenticated administrative users to execute arbitrary OS commands with root privileges, resulting in complete device compromise. This directly threatens network infrastructure availability and security; no public exploit identified at time of analysis, but the credential requirement provides only a single control barrier against internal threats and credential compromise.

Business Impact: High
Compensating Controls

Apply vendor patch.

Threat Intelligence Overview

EPSS Score
3.1%
Top 13% exploitable
Prevalence
Medium
popular SMB and mid-market managed switch vendor, broad model lineup
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 3.1%
Patch available Yes
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Open
Automatable
No
Human Impact
High
Technical Impact
Total

Priority Score

46
Low Medium High Critical
KEV: 0
EPSS: +3
CVSS: +43
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

CVE-2026-71921 CRITICAL
9.3 Aug 24

Pre-authentication OS command injection in DrayTek VigorSwitch managed switches lets a remote, unauthenticated attacker

CVE-2026-71943 HIGH
8.6 Aug 24

Command injection in DrayTek VigorSwitch's setDevNet function allows authenticated remote attackers to execute arbitrary

CVE-2026-71930 HIGH
8.6 Aug 24

Command injection in DrayTek VigorSwitch's setTime function enables authenticated administrators to execute arbitrary OS

CVE-2026-71929 HIGH
8.6 Aug 24

Command injection in multiple DrayTek VigorSwitch models enables authenticated administrators to execute arbitrary OS co

CVE-2026-71925 HIGH
8.6 Aug 24

Command injection in multiple DrayTek VigorSwitch models' getDetail function enables authenticated remote attackers hold

CVE-2026-71924 HIGH
8.6 Aug 24

Command injection in DrayTek VigorSwitch's getVid function allows an authenticated remote administrator to execute arbit

CVE-2026-71919 HIGH
8.6 Aug 24

Command injection in multiple DrayTek VigorSwitch managed switch models allows an authenticated remote administrator to

CVE-2026-71917 HIGH
8.6 Aug 24

Command injection in the DrayTek VigorSwitch series' pingtrace diagnostic function allows an authenticated administrator

CVE-2026-71915 HIGH
8.6 Aug 24

Command injection in DrayTek VigorSwitch's jsonstatus function allows authenticated remote administrators to execute arb

CVE-2026-71931 HIGH
8.6 Aug 24

Command injection in DrayTek VigorSwitch's tftp_upgrade function enables authenticated remote administrators to execute

CVE-2026-71916 HIGH
8.6 Aug 24

Command injection via the commandTable function affects 28 DrayTek VigorSwitch managed switch models across multiple fir

CVE-2026-71928 HIGH
8.6 Aug 24

Command injection in DrayTek VigorSwitch firmware's fdftDevice function allows an authenticated remote administrator to

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy