Skip to main content
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Obtain admin credentials via phishing or credential reuse
  2. Delivery
    Reach VigorSwitch web management interface over network
  3. Exploit
    Craft malicious username or password with shell metacharacters
  4. Execution
    Submit crafted input to getDetail function
  5. Persist
    Injected OS commands execute as root
  6. Impact
    Achieve full device compromise

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization OS command sanitization, avoid shell exec
MITRE ATT&CK

2 techniques across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Exploitation requires valid administrative credentials for the device's web management interface, confirmed by PR:H in the CVSS 4.0 vector. The management interface must be network-accessible from the attacker's position (AV:N). The specific vulnerable code path is the getDetail function's handling of the username and password input fields - meaning the attacker must be able to interact with the authentication or post-authentication management flow to inject commands. No user interaction beyond the attacker's own session is required (UI:N). Exploitation is bounded by three concrete prerequisites: (1) possession of valid admin-level credentials, (2) network reachability to the web management interface, and (3) a vulnerable firmware version running on one of the affected models. Devices whose management interface is isolated to a dedicated management VLAN or blocked at perimeter have materially reduced exposure despite the network attack vector.

Impact

The CVSS 4.0 score of 8.6 is materially constrained by PR:H, meaning an attacker must first possess valid administrative credentials before exploitation is possible. The network attack vector (AV:N) and low attack complexity (AC:L, AT:N) indicate that once credentials are in hand, exploitation is straightforward and remotely executable without interaction. The full C:H/I:H/A:H impact on the vulnerable system reflects root-level command execution, which is severe - but restricted to actors who already control an admin account. No CISA KEV listing is present in the provided data, and no public exploit or POC has been identified, which tempers urgency relative to the raw score. EPSS data was not provided. Real-world risk is highest for organizations that expose VigorSwitch management interfaces to untrusted networks or that practice credential reuse across devices, and lower for environments where management plane access is strictly firewalled. The absence of a scope change (SC:N/SI:N/SA:N) bounds blast radius to the compromised switch itself, though switch-level compromise carries significant network-interception and pivoting potential.

Exploit ScenarioDerived

An attacker who has obtained valid VigorSwitch administrative credentials - through phishing, credential stuffing, insider access, or reuse of credentials stolen from another system - authenticates to the web management interface and submits a crafted request to the getDetail function with shell metacharacters embedded in the username or password fields. Because input sanitization is absent, the injected payload is interpreted by the underlying OS and executed as root, granting the attacker full control of the switch firmware, the ability to exfiltrate management-plane secrets, or the ability to intercept or manipulate network traffic traversing the device.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
Patch available 3.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Aug 24, 2026

Command injection in multiple DrayTek VigorSwitch models' getDetail function enables authenticated remote attackers holding valid administrative credentials to execute arbitrary OS commands with root privileges. The flaw (CWE-78) arises from the web management interface failing to sanitize username and password fields before incorporating them into system command execution. DrayTek published a security advisory in August 2026 covering a broad range of VigorSwitch models; no public exploit code or CISA KEV listing has been identified at time of analysis.

RemediationAI

Apply firmware updates per DrayTek's official security advisory at https://www.draytek.com/about/security-advisory/multiple-vulnerabilities-in-vigorswitch-series-august-2026/. Patched firmware version numbers were not independently confirmed from the available data - consult the advisory to identify the minimum safe version for each specific model. As an immediate compensating control, restrict access to the VigorSwitch web management interface to dedicated, firewalled management VLANs or out-of-band management networks; blocking internet-facing exposure significantly reduces real-world attack surface given the PR:H requirement. Enforce strong, unique administrative credentials on all VigorSwitch devices and rotate credentials immediately if reuse with other systems is suspected. If remote web management is not operationally required, disable it entirely and manage devices in-person or via a jump host. Note that credential restriction does not eliminate risk if an insider threat or already-compromised management host is the attacker.

Affected VersionsENISA

VigorSwitch G2542x 0 <3.10.6
VigorSwitch PQ2200xb 0 <2.9.10
VigorSwitch P2280x 0 <2.9.10
VigorSwitch G2100 0 <2.9.10
VigorSwitch G2540xs 0 <3.9.10
VigorSwitch G2121 0 <2.9.10
VigorSwitch P1281x 0 <2.9.10
VigorSwitch P1280 0 <2.9.10
VigorSwitch P1282 0 <2.9.10
VigorSwitch G2282x 0 <2.10.6
VigorSwitch Q2200x 0 <2.9.10
VigorSwitch P2282x 0 <2.10.6
VigorSwitch G2540x 0 <2.9.10
VigorSwitch G2280x 0 <2.9.10
VigorSwitch Q2300x 0 <2.10.7
VigorSwitch P2121 0 <2.9.10
VigorSwitch P2542x 0 <3.10.6
VigorSwitch G1280 0 <2.9.10
VigorSwitch PQ2121x 0 <2.9.10
VigorSwitch P2540xs 0 <3.9.10
VigorSwitch Q2121x 0 <2.9.10
VigorSwitch P2542xh 0 <3.10.6
VigorSwitch P2100 0 <2.9.10
VigorSwitch G1282 0 <2.9.10
VigorSwitch FX2120 0 <3.9.10
VigorSwitch P2540x 0 <2.9.10
VigorSwitch PQ2300xb 0 <2.10.7
VigorSwitch PX2060 0 <2.9.10

Affected Packages

euvd vigorswitch_fx2120 fix: 3.9.10
euvd vigorswitch_g1280 fix: 2.9.10
euvd vigorswitch_g1282 fix: 2.9.10
euvd vigorswitch_g2100 fix: 2.9.10
euvd vigorswitch_g2121 fix: 2.9.10
euvd vigorswitch_g2280x fix: 2.9.10
euvd vigorswitch_g2282x fix: 2.10.6
euvd vigorswitch_g2540x fix: 2.9.10
euvd vigorswitch_g2540xs fix: 3.9.10
euvd vigorswitch_g2542x fix: 3.10.6
euvd vigorswitch_p1280 fix: 2.9.10
euvd vigorswitch_p1281x fix: 2.9.10
euvd vigorswitch_p1282 fix: 2.9.10
euvd vigorswitch_p2100 fix: 2.9.10
euvd vigorswitch_p2121 fix: 2.9.10
euvd vigorswitch_p2280x fix: 2.9.10
euvd vigorswitch_p2282x fix: 2.10.6
euvd vigorswitch_p2540x fix: 2.9.10
euvd vigorswitch_p2540xs fix: 3.9.10
euvd vigorswitch_p2542x fix: 3.10.6
euvd vigorswitch_p2542xh fix: 3.10.6
euvd vigorswitch_pq2121x fix: 2.9.10
euvd vigorswitch_pq2200xb fix: 2.9.10
euvd vigorswitch_pq2300xb fix: 2.10.7
euvd vigorswitch_px2060 fix: 2.9.10
euvd vigorswitch_q2121x fix: 2.9.10
euvd vigorswitch_q2200x fix: 2.9.10
euvd vigorswitch_q2300x fix: 2.10.7

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 28 packages in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

CWE-78 (Improper Neutralization of Special Elements used in an OS Command) identifies the root cause: the getDetail function in the VigorSwitch web management backend passes attacker-controlled username and password fields directly into an OS command context without stripping or escaping shell metacharacters, enabling classic command injection. CPE data confirms at least ten distinct VigorSwitch models are affected - G2540XS, P2540XS, FX2120, G2282X, P2282X, Q2300X, PQ2300XB, G2542X, P2542X, and P2542XH - with tags extending the scope to nearly 28 models including G1280, P1280, G2121, P2121, G2100, and others. The CVSS 4.0 vector AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N confirms network-reachable exploitation by an authenticated administrator with full triad impact on the device and no lateral scope change to subsequent systems.

Know when Vigorswitch G2540Xs gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (VulnCheck) PRIMARY 8.6 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
vuln.today AI 7.2 HIGH

Admin credentials required (PR:H); network-accessible with no special conditions (AV:N/AC:L); root command execution yields full CIA impact; no scope change as blast radius stays within the switch.

3.1 AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (VulnCheck).

CVSS VectorVendor: VulnCheck

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
High
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

2
Patch available
Aug 24, 2026 - 18:02 EUVD
CVE Published
Aug 24, 2026 - 17:07 cve.org
HIGH 8.6

DescriptionCVE.org

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the getDetail function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface.

Executive ViewAI

Why It Matters

DrayTek VigorSwitch network switches contain a command injection vulnerability (CVSS 8.6) enabling administrative users to execute arbitrary OS commands with root privileges. No public exploit has been identified at time of analysis, but organizations using affected VigorSwitch models face significant infrastructure compromise risks including data exfiltration and lateral network movement.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations include: restrict administrative access through network segmentation and multi-factor authentication, disable web-based management interfaces where operationally feasible, implement enhanced logging and monitoring for all administrative account activities, deploy network-based IDS/IPS rules to detect command injection patterns, isolate affected devices to a dedicated, restricted management network segment, and implement strict access controls limiting administrative interface connectivity to authorized personnel and systems.

Threat Intelligence Overview

EPSS Score
3.1%
Top 13% exploitable
Prevalence
Medium
popular SMB managed switch vendor, significant Asia-Pacific and UK deployment
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 3.1%
Patch available Yes
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Open
Automatable
No
Human Impact
High
Technical Impact
Total

Priority Score

46
Low Medium High Critical
KEV: 0
EPSS: +3
CVSS: +43
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

CVE-2026-71921 CRITICAL
9.3 Aug 24

Pre-authentication OS command injection in DrayTek VigorSwitch managed switches lets a remote, unauthenticated attacker

CVE-2026-71943 HIGH
8.6 Aug 24

Command injection in DrayTek VigorSwitch's setDevNet function allows authenticated remote attackers to execute arbitrary

CVE-2026-71930 HIGH
8.6 Aug 24

Command injection in DrayTek VigorSwitch's setTime function enables authenticated administrators to execute arbitrary OS

CVE-2026-71929 HIGH
8.6 Aug 24

Command injection in multiple DrayTek VigorSwitch models enables authenticated administrators to execute arbitrary OS co

CVE-2026-71924 HIGH
8.6 Aug 24

Command injection in DrayTek VigorSwitch's getVid function allows an authenticated remote administrator to execute arbit

CVE-2026-71919 HIGH
8.6 Aug 24

Command injection in multiple DrayTek VigorSwitch managed switch models allows an authenticated remote administrator to

CVE-2026-71918 HIGH
8.6 Aug 24

Command injection in the DrayTek VigorSwitch `webBackupAction` function allows authenticated remote attackers to execute

CVE-2026-71917 HIGH
8.6 Aug 24

Command injection in the DrayTek VigorSwitch series' pingtrace diagnostic function allows an authenticated administrator

CVE-2026-71915 HIGH
8.6 Aug 24

Command injection in DrayTek VigorSwitch's jsonstatus function allows authenticated remote administrators to execute arb

CVE-2026-71931 HIGH
8.6 Aug 24

Command injection in DrayTek VigorSwitch's tftp_upgrade function enables authenticated remote administrators to execute

CVE-2026-71916 HIGH
8.6 Aug 24

Command injection via the commandTable function affects 28 DrayTek VigorSwitch managed switch models across multiple fir

CVE-2026-71928 HIGH
8.6 Aug 24

Command injection in DrayTek VigorSwitch firmware's fdftDevice function allows an authenticated remote administrator to

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy