Unisphere For Powermax
CVE-2026-26360
HIGH
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessAuthenticate as low-privileged user
-
ExploitCraft malicious file path request
-
ExecutionBypass path validation controls
-
ImpactDelete arbitrary system files
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A06:2025 - Insecure Design
ASVS 5.0
V5 - File Handling File name/path control
|
| Exploitation Conditions | Dell Unisphere for PowerMax version 10.2 with low-privileged user account credentials required. Remote network access to the Unisphere management interface mandatory. |
| Impact | CVSS 8.1 (HIGH). Attack vector: Network. Complexity: Low. Privileges required: Low. User interaction: None. Exploitable via remote/network. |
| Exploit ScenarioDerived | A remote attacker could exploit this vulnerability to compromise the affected system. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Mar 12, 2026
Dell Unisphere for PowerMax versions 10.2 suffer from a path traversal vulnerability (CWE-73) that allows authenticated remote attackers to delete arbitrary files on affected systems. An attacker with low-level privileges can exploit this flaw without user interaction to achieve denial of service or system compromise. No patch is currently available for this high-severity issue (CVSS 8.1).
Earlier versions of this analysis (1)
Dell Unisphere for PowerMax, version(s) 10.2, contain(s) an External Control of File Name or Path vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability to delete arbitrary files. [CVSS 8.1 HIGH]
RemediationAI
Monitor vendor advisories for a patch. Restrict network access to the affected service where possible.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
Affects Unisphere For Powermax. Dell Unisphere for PowerMax, version(s) 10.2, contain(s) an External Control of File Name or Path vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability to delete arbitrary files.
Know when Unisphere For Powermax gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionCVE.org
Dell Unisphere for PowerMax, version(s) 10.2, contain(s) an External Control of File Name or Path vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability to delete arbitrary files.
Executive ViewAI
Dell Unisphere for PowerMax version 10.2 contains a critical vulnerability allowing remote attackers with low privileges to delete arbitrary files, potentially disrupting storage management operations and data integrity. Organizations using this platform face immediate risk of unauthorized file destruction and operational disruption until mitigation measures are implemented.
Implement network segmentation restricting Unisphere console access to a management VLAN with strict firewall rules; enforce multi-factor authentication for all Unisphere administrative accounts; deploy file integrity monitoring on critical system directories; enable comprehensive audit logging with SIEM integration; restrict user privilege levels to minimum necessary permissions; consider disabling remote access capabilities if operationally feasible; implement backup and file versioning strategies to enable rapid recovery from unauthorized deletions.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Affected Products (CPE)CVE.org
More in Unisphere For Powermax
View allRemote command execution in Dell Unisphere for PowerMax versions 10.3.0.5 and prior allows a low-privileged authenticate
Dell Unisphere for PowerMax, version(s) 10.2.0.x, contain(s) an Improper Neutralization of Special Elements used in an S
Dell Unisphere for PowerMax 10.2 lacks proper authorization checks, allowing authenticated remote attackers to bypass ac
Dell Unisphere for PowerMax 10.2 contains a path traversal vulnerability that allows authenticated remote attackers to o
Dell Unisphere for PowerMax 10.2 contains a relative path traversal flaw that allows authenticated remote attackers to m
Unisphere for PowerMax versions before 9.2.3.15 contain a privilege escalation vulnerability. Rated high severity (CVSS
Dell Unisphere for PowerMax versions prior to 9.2.1.6 contain an Authorization Bypass Vulnerability. Rated high severity
Improper authorization in Dell Unisphere for PowerMax (the VMAX management application running inside the vApp/Virtual A
Exploitation of an XML External Entity (XXE) flaw in Dell Unisphere for PowerMax 9.2.4.x and its virtual appliance allow
Path traversal in Dell Unisphere for PowerMax 10.3.0.5 and prior exposes arbitrary files on the underlying server to rem
Dell Unisphere for PowerMax 10.2 contains a file path control vulnerability that allows authenticated remote attackers t
Unauthorized file disclosure in Dell Unisphere for PowerMax 10.3.0.5 and prior is achievable by a remote low-privileged
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB