Solutions Enabler Virtual Appliance CVE-2022-31233

HIGH
Client-Side Enforcement of Server-Side Security (CWE-602)
2022-08-31 security_alert@emc.com
8.0
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
8.0 HIGH
AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Adjacent
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Aug 31, 2022 - 20:15 nvd
HIGH 8.0

DescriptionNVD

Unisphere for PowerMax versions before 9.2.3.15 contain a privilege escalation vulnerability. An adjacent malicious user may potentially exploit this vulnerability to escalate their privileges and access functionalities they do not have access to.

AnalysisAI

Unisphere for PowerMax versions before 9.2.3.15 contain a privilege escalation vulnerability. Rated high severity (CVSS 8.0), this vulnerability is low attack complexity.

Technical ContextAI

This vulnerability is classified under CWE-602. Unisphere for PowerMax versions before 9.2.3.15 contain a privilege escalation vulnerability. An adjacent malicious user may potentially exploit this vulnerability to escalate their privileges and access functionalities they do not have access to. Affected products include: Dell Evasa Provider Virtual Appliance, Dell Solutions Enabler, Dell Solutions Enabler Virtual Appliance, Dell Unisphere 360, Dell Unisphere For Powermax. Version information: before 9.2.3.15.

RemediationAI

A vendor patch is available. Apply the latest security update as soon as possible. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

CVE-2024-25955 HIGH
8.8 Mar 28

Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. Rated high severity (CVSS 8.8),

CVE-2024-25946 HIGH
8.8 Mar 28

Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. Rated high severity (CVSS 8.8),

CVE-2021-21531 HIGH
7.8 Apr 30

Dell Unisphere for PowerMax versions prior to 9.2.1.6 contain an Authorization Bypass Vulnerability. Rated high severity

CVE-2023-48671 HIGH
7.5 Dec 14

Dell vApp Manager, versions prior to 9.2.4.x contain an information disclosure vulnerability. Rated high severity (CVSS

CVE-2023-48660 HIGH
7.5 Dec 14

Dell vApp Manger, versions prior to 9.2.4.x contain an arbitrary file read vulnerability. Rated high severity (CVSS 7.5)

CVE-2025-36595 HIGH
7.2 Jun 27

A remote code execution vulnerability (CVSS 7.2). High severity vulnerability requiring prompt remediation.

CVE-2023-48665 HIGH
7.2 Dec 14

Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. Rated high severity (CVSS 7.2),

CVE-2023-48664 HIGH
7.2 Dec 14

Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. Rated high severity (CVSS 7.2),

CVE-2023-48663 HIGH
7.2 Dec 14

Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. Rated high severity (CVSS 7.2),

CVE-2023-48662 HIGH
7.2 Dec 14

Dell vApp Manager, versions prior to 9.2.4.x contain a command injection vulnerability. Rated high severity (CVSS 7.2),

CVE-2023-48661 MEDIUM
4.9 Dec 14

Dell vApp Manager, versions prior to 9.2.4.x contain an arbitrary file read vulnerability. Rated medium severity (CVSS 4