Skip to main content

Tenable Sensor Proxy CVE-2026-18667

| EUVDEUVD-2026-52490 CRITICAL
Code Injection (CWE-94)
2026-08-03 tenable GHSA-24h7-mgmp-x4j6
9.3
CVSS 4.0 · Vendor: tenable
Share

Severity by source

Vendor (tenable) PRIMARY
9.3 CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
vuln.today AI
8.8 HIGH

Network vector with low complexity and no auth, but the description's operator-induced connection makes this UI:R rather than UI:N; full CIA impact on the proxy host.

3.1 AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (tenable).

CVSS VectorVendor: tenable

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
X

Lifecycle Timeline

6
Analysis Updated
Aug 03, 2026 - 23:28 vuln.today
v2 (cvss_changed)
Re-analysis Queued
Aug 03, 2026 - 23:22 vuln.today
cvss_changed
CVSS changed
Aug 03, 2026 - 23:22 NVD
9.6 (CRITICAL) 9.3 (CRITICAL)
Patch available
Aug 03, 2026 - 23:02 EUVD
Analysis Generated
Aug 03, 2026 - 22:50 vuln.today
CVE Published
Aug 03, 2026 - 22:27 cve.org
CRITICAL 9.6

DescriptionCVE.org

A vulnerability in Tenable Sensor Proxy allows a remote attacker to execute code with elevated privileges by inducing an operator to connect the sensor to an attacker-controlled host.

AnalysisAI

Remote code execution in Tenable Sensor Proxy (versions before 1.4.2) lets an attacker run code with elevated privileges by luring an operator into connecting the sensor to an attacker-controlled host. The CWE-94 code-injection flaw is triggered during that connection, and the CVSS 4.0 score of 9.3 reflects full compromise of confidentiality, integrity, and availability on the proxy host. There is no public exploit identified at time of analysis and it is not on CISA KEV, but a vendor patch is available.

Technical ContextAI

Tenable Sensor Proxy is a component of Tenable's vulnerability-management ecosystem (Nessus / Tenable Vulnerability Management / Security Center) that relays scan traffic between distributed sensors and the management backend; the affected product per CPE is cpe:2.3:a:tenable,_inc.:sensor_proxy. The root cause is CWE-94 (Improper Control of Generation of Code, i.e. code injection): when the sensor is directed to connect to a malicious upstream host, that host supplies content the proxy interprets and executes, running with the elevated privileges the proxy process holds.

RemediationAI

Vendor-released patch: upgrade Tenable Sensor Proxy to version 1.4.2 or later per the Tenable advisory at https://www.tenable.com/security/tns-2026-21. Until upgrading, the most effective compensating control targets the specific precondition: ensure operators connect sensors only to known, pre-validated management hosts and reject any prompt or instruction to point a sensor at an unverified endpoint (side effect: adds operational friction to legitimate re-provisioning). Additionally, restrict outbound paths from sensor hosts with egress firewall rules that permit only the approved Tenable backend addresses (side effect: breaks connectivity if backend IPs change without a rule update), which prevents a sensor from reaching an attacker-controlled host even if an operator is tricked.

Share

CVE-2026-18667 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy