Skip to main content

CODESYS Visualization CVE-2026-121016

| EUVDEUVD-2026-133709 HIGH
Incorrect Resource Transfer Between Spheres (CWE-669)
2026-11-24 CERTVDE
8.6
CVSS 4.0 · Vendor: CERTVDE
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Lure engineer to malicious runtime or gain MITM position
  2. Delivery
    Deliver crafted visualization data over runtime channel
  3. Exploit
    Engineer opens/operates visualization (UI:A)
  4. Execution
    Insufficiently restricted data triggers local program execution
  5. Impact
    Arbitrary code execution on engineering workstation

Vulnerability Assessment

Weakness
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Incorrect resource transfer between spheres
Exploitation Conditions

Exploitation requires that a user be simultaneously logged in to a CODESYS Control runtime AND actively operating a CODESYS Visualization on the engineering workstation (UI:A). The attacker must additionally obtain one of two positions: (a) control of a malicious CODESYS Control runtime plus successfully social-engineering the user into trusting/connecting to it, or (b) an active man-in-the-middle position on the communication channel between the legitimate CODESYS Control runtime and the engineering workstation. The flaw is the insufficient restriction of runtime-supplied visualization data (CWE-669), which allows attacker-supplied data to cause local program execution on the workstation. Limiting factors: required user interaction with an active visualization session, the need for a trust-relationship deception or a privileged network MITM position, and that the target is the engineering workstation rather than the runtime/PLC itself (no subsequent-system impact, SC/SI/SA:N).

Impact

Signals are moderate-to-serious but not emergency. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:A, VC:H/VI:H/VA:H, score 8.6) describes unauthenticated remote code execution on the engineering workstation with full confidentiality, integrity and availability impact and no scope change (SC/SI/SA:N). The vuln.today decision label is 'this_week', consistent with a high-severity flaw that is not under active exploitation. Critically, exploitation is gated by two real-world prerequisites captured in the description but under-weighted by AC:L: the attacker must either lure a victim into trusting a malicious CODESYS Control runtime or hold a man-in-the-middle position on the runtime-to-workstation channel, AND the victim must be logged in and actively operating a visualization (UI:A). No EPSS score, KEV listing, or PoC is provided in the input, so there is no public exploit identified at time of analysis and no evidence of active or widespread exploitation. Net: a genuine high-impact OT/ICS issue warranting prompt patching on engineering workstations, but the MITM/social-engineering precondition and required user interaction make mass, opportunistic exploitation unlikely - this is closer to a targeted-attack risk than a wormable internet-facing bug. Note: the input provides a CVSS 4.0 vector only; no 3.1 vector, EPSS, or SSVC decision-point breakdown is supplied, so those signals cannot be cross-compared.

Exploit ScenarioDerived

An attacker either stands up a malicious CODESYS Control runtime and convinces an engineer to connect to and trust it, or inserts themselves as a man-in-the-middle on the network path between a legitimate runtime and the engineering workstation. When the logged-in engineer opens or operates the visualization, attacker-controlled visualization data is processed insufficiently restricted, triggering local program execution and arbitrary code execution on the workstation. No public exploit is identified in the provided data.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
Patch available

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Nov 24, 2026

Arbitrary code execution on a CODESYS engineering workstation can be triggered through visualization data supplied at runtime by a CODESYS Control runtime. The attacker must be unauthenticated but remote, and must either operate a malicious runtime that the victim is persuaded to trust, or hold a man-in-the-middle position on the link between the legitimate runtime and the engineering workstation; execution only occurs while a user is simultaneously logged in to a runtime and actively operating a visualization. Rated CVSS 4.0 8.6 (AV:N/AC:L/AT:N/PR:N/UI:A, all confidentiality/integrity/availability impacts high, no subsequent-system impact); the vuln.today decision label is this_week, no public exploit code was identified at time of analysis, and no KEV listing or EPSS score was supplied.

RemediationAI

No fixed version is listed in the available data: patch status for CVE-2026-121016 is 'No vendor-released patch identified at time of analysis', so the exact remediated release must be taken from CERTVDE advisory VDE-2026-154 (https://www.certvde.com/en/advisories/VDE-2026-154/) and applied to the CODESYS Visualization / engineering workstation component once published. In the interim, mitigations follow directly from the stated preconditions: restrict engineering workstations from connecting to CODESYS Control runtimes outside a known-good, inventoried set, since the attack requires either a malicious runtime the user is tricked into trusting or an active man-in-the-middle position (trade-off: blocks legitimate ad-hoc or field commissioning work against unknown controllers); and protect the runtime-to-workstation channel with authenticated/encrypted transport or a segmented management network so a MITM position cannot be obtained (trade-off: added configuration overhead and possible incompatibility with legacy controllers). Neither control removes the underlying CWE-669 weakness, and both reduce rather than eliminate exposure while a user is logged in and operating a visualization, which is the state in which exploitation occurs.

Affected VersionsENISA

Visualization 3.0.0.0 <4.11.0.0

Affected Packages

euvd visualization fix: 4.11.0.0

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The flaw is classified as CWE-669 (Incorrect Resource Transfer Between Spheres): visualization content that originates in the CODESYS Control runtime crosses a trust boundary into the engineering workstation tooling, and the affected products do not sufficiently restrict what that runtime-supplied data is allowed to do once it is processed locally. Because the engineering workstation client consumes visualization definitions from the controller rather than from a locally vetted source, a runtime that is malicious, or traffic that is modified in transit, can hand the client data that results in local program execution in the workstation context. The affected component is identified by CPE cpe:2.3:a:codesys:visualization:*:*:*:*:*:*:*:*, i.e. the visualization component across unspecified versions rather than a single fixed release. Two scores exist: the published CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N, 8.6) and an independent CVSS 3.1 assessment (AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H) that treats the attack as high complexity because a trust-deception or network man-in-the-middle position is a prerequisite. Both agree that authentication is not required (PR:N), that user interaction is required, and that the impact is confined to the engineering workstation with no subsequent-system consequences.

Know when Visualization gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (CERTVDE) PRIMARY 8.6 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
vuln.today AI 7.5 HIGH

Unauthenticated (PR:N) but needs a MITM position or luring the user to trust a malicious runtime (AC:H) plus an active visualization session (UI:R); full RCE on the workstation gives C/I/A:H, no scope change.

3.1 AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (CERTVDE).

CVSS VectorVendor: CERTVDE

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
Active
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

2
Patch available
Nov 24, 2026 - 09:01 EUVD
CVE Published
Nov 24, 2026 - 07:51 cve.org
HIGH 8.6

DescriptionCVE.org

The affected products insufficiently restrict runtime-supplied visualization data, allowing local program execution on the engineering workstation, if a user is both logged in to a CODESYS Control runtime and operates a visualization. An unauthenticated remote attacker controlling a malicious runtime and tricking a user to trust it, or performing a man-in-the-middle attack on the communication between the CODESYS Control runtime and the engineering workstation, may cause arbitrary code execution on the engineering workstation.

Executive ViewAI

Why It Matters

A high-severity vulnerability in CODESYS engineering workstation software allows remote, unauthenticated attackers to execute arbitrary code by compromising the runtime environment or intercepting communications, specifically while an engineer is actively using visualization tools. This puts engineering workstations at risk, potentially enabling attackers to pivot into operational technology networks, disrupt production, or steal sensitive data. Leadership should prioritize mitigation because exploitation could lead to significant operational downtime and safety incidents.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations include network segmentation, restricting remote runtime connections, enforcing TLS with mutual authentication, deploying endpoint detection, monitoring for anomalous visualization traffic, and user awareness training to avoid trusting malicious runtimes.

Threat Intelligence Overview

Prevalence
Medium
widely used ICS/PLC runtime, but industrial-sector-specific engineering-workstation footprint
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS N/A
Patch available Yes
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
No
Human Impact
High

Priority Score

43
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +43
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy