Skip to main content

Tenda HG10 CVE-2026-11499

| EUVDEUVD-2026-35029 CRITICAL
Stack-based Buffer Overflow (CWE-121)
2026-06-08 VulDB GHSA-xv62-77m9-3736
9.3
CVSS 4.0 · Vendor: VulDB
Share

Severity by source

Vendor (VulDB) PRIMARY
9.3 CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from Vendor (VulDB) · only source for this CVE.

CVSS VectorVendor: VulDB

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
X

Lifecycle Timeline

2
Analysis Generated
Jun 08, 2026 - 10:35 vuln.today
CVSS changed
Jun 08, 2026 - 09:22 NVD
9.8 (CRITICAL) 9.3 (CRITICAL)

DescriptionCVE.org

A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.

AnalysisAI

Stack-based buffer overflow in Tenda HG7HG9 and HG10 routers (firmware 300001138_en_xpon) allows remote attackers to corrupt memory via the blkDomain parameter in the formDOMAINBLK handler at /boaform/formDOMAINBLK. The CVSS 4.0 score of 9.3 reflects network-reachable, unauthenticated exploitation with high impact to confidentiality, integrity, and availability, and a public proof-of-concept repository has been published on GitHub by researcher ssaaaa1234, though no public exploit has been confirmed as active exploitation.

Technical ContextAI

The vulnerable component is the boa web server's formDOMAINBLK handler, used for domain blocking/filtering configuration on Tenda HG-series xPON ONT (optical network termination) gateways. CWE-121 (stack-based buffer overflow) indicates the blkDomain argument is copied into a fixed-size stack buffer without proper length validation, enabling overwrite of the saved return address or adjacent stack data. The CPE strings cpe:2.3:a:tenda:hg7hg9 and cpe:2.3:a:tenda:hg10 identify the two affected device families, both running firmware build 300001138_en_xpon. These devices are typically deployed as customer-premise equipment by ISPs for fiber broadband subscribers, often with administrative web interfaces exposed on the LAN and, in some misconfigurations, on the WAN side.

RemediationAI

No vendor-released patch identified at time of analysis - Tenda has not published an advisory or fixed firmware build for HG7HG9 or HG10 300001138_en_xpon in the provided references. Operators should monitor https://www.tenda.com.cn/ for an updated firmware release and apply it as soon as available. As compensating controls, disable the WAN-side administrative web interface so /boaform/formDOMAINBLK is unreachable from the internet (this prevents remote field provisioning but eliminates external exposure), restrict LAN access to the management interface via ACL to a dedicated management VLAN or jump host (this breaks casual user access to router admin), and block inbound TCP 80/443 to the device at the upstream firewall. ISPs managing fleets should consider TR-069/ACS-side filtering of suspicious blkDomain payload patterns. Track the public POC at https://github.com/ssaaaa1234/Tenda-HG10-formDOMAINBLK-stack-overflow-2 to validate detection signatures.

Share

CVE-2026-11499 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy