Skip to main content

Rockwell Automation Device CVE-2025-9177

HIGH
Allocation of Resources Without Limits or Throttling (CWE-770)
2025-10-14 PSIRT@rockwellautomation.com
7.7
CVSS 4.0 · Vendor: rockwellautomation
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Reach device web server over network
  2. Delivery
    Send high volume of requests
  3. Exploit
    Exhaust server resources (CWE-770)
  4. Execution
    Crash web management interface
  5. Impact
    Management webpage unavailable until power cycle

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2025 - Insecure Design
ASVS 5.0
V2 - Validation and Business Logic Resource allocation limits
MITRE ATT&CK

1 technique across 1 tactic: Impact

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Exploitation requires network reachability to the affected Rockwell Automation device's embedded web server and the ability to send a high volume of requests to it; per CVSS PR:N/UI:N no authentication or user interaction is needed against the exposed web interface. Limiting factors: impact is confined to the web management interface - the advisory explicitly states I/O control and communication are NOT affected - so the practical consequence is loss of the webpage, and recovery requires physical/manual power-cycle access rather than offering the attacker any code execution, data access, or control-system disruption. Real-world exposure is further limited where the device web server is segmented off untrusted networks, which is standard OT practice.

Impact

Signals are largely consistent in pointing to a moderate, availability-only risk. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:N) indicates a remotely reachable, low-complexity, unauthenticated flaw, which is why the base score lands at 7.7; however, the only non-zero impact is SA:H (subsequent-system availability), with VC:N/VI:N/VA:N - i.e., no confidentiality or integrity impact and no direct impact on the vulnerable component itself, consistent with the CWE-770 resource-exhaustion / DoS nature. EPSS is low at 0.32% (23rd percentile), and the CVE is NOT in CISA KEV with no public exploit identified, so despite the network-facing unauthenticated vector this is not evidence of widespread or active exploitation. Note a signal nuance to verify with the vendor: the 4.0 vector encodes availability impact as SA:H (subsequent system) while VA:N (vulnerable system is unaffected) - this is an unusual split for a web-server crash and suggests the scoring party treated the device/process as the impacted subsequent system; functionally the real effect is loss of the web management interface. The description's own mitigating statement - that I/O control and communication are NOT affected - materially lowers operational risk in an OT context, so this reads as a genuine-but-contained availability issue rather than a top-priority critical, with the main concern being that recovery requires a manual power cycle.

Exploit ScenarioDerived

A remote, unauthenticated attacker with network reachability to the device's embedded web server floods it with a high volume of requests, exhausting resources until the web server crashes. The management webpage becomes unavailable and, per the advisory, a physical power cycle is required to restore it; underlying I/O control and communication continue to function. No public exploit code has been identified, but the low complexity makes a crafted request-flooding script trivial to produce.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.3% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Oct 08, 2026

A denial-of-service condition affects Rockwell Automation devices whose embedded web server cannot handle a high volume of requests, allowing a remote, unauthenticated attacker to crash the web interface; the product and firmware range are not named in the available data but are documented in Rockwell advisory SD1757. Recovery is disruptive rather than remote - the unit must be power cycled physically to restore the webpage, while I/O control and communications continue to function normally, so the operational impact is confined to loss of web-based monitoring/configuration access. Scoring 7.7 under CVSS 4.0 (assessed 3.1 AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H), the flaw is availability-only, and there is no public exploit identified at time of analysis, with EPSS at 0.32% (23rd percentile) indicating low predicted exploitation likelihood; no CISA KEV listing applies.

RemediationAI

No vendor-released patch version is identified in the provided data; the authoritative remediation path is Rockwell Automation advisory SD1757 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1757.html), which should be consulted for the fixed firmware revision and update/flash procedure - treat any firmware listed there as the required minimum before re-exposing the web interface. Until a firmware update is applied and verified, apply these compensating controls: block TCP/80 and TCP/443 (or the device's configured web ports) at the OT firewall so only trusted engineering workstations can reach the embedded server, accepting the trade-off that remote diagnostics and HMI page access must originate from those hosts; if the web interface is not operationally required, disable it entirely, which removes the attack surface at the cost of losing browser-based status/configuration views; place the device behind an IPS or reverse proxy with per-source HTTP request rate limiting and connection caps, acknowledging that inline inspection adds latency and a new failure point on an OT segment; and monitor for anomalous request bursts against the device's web port to detect a flood in progress. Plan for physical or remote-power-management access (switched PDU, on-site staff) so a required power cycle can be performed quickly, since the advisory states recovery demands a manual power cycle and there is no software restart path described.

Affected ProductsAI

The specific product name and version range are not enumerated in the supplied data. The advisory reference is Rockwell Automation's security advisory SD1757 at https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1757.html, reported by PSIRT@rockwellautomation.com, which identifies the affected Rockwell Automation product(s) and firmware revisions; no CPE strings were included in this feed, so exact model numbers cannot be confirmed here. Based on the advisory's own statement that I/O control and communication are unaffected, the affected component is the device's embedded web server on the models listed in SD1757. Operators should inventory devices against that advisory rather than relying on a version range reproduced here, since inventing one would be inaccurate.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The root cause class is CWE-770, Allocation of Resources Without Limits or Throttling: the affected product's embedded web server accepts and processes requests without adequate rate limiting, queue bounding, or connection throttling, so a flood of HTTP traffic exhausts the resources the daemon needs and it terminates. Because the web service is embedded in an OT/industrial device rather than a general-purpose application server, there is typically no supervisor process to auto-restart it, which is why the advisory notes a manual power cycle is required to bring the page back. The CVSS 4.0 vector published with the advisory (AV:N/AC:L/AT:N/PR:N/UI:N with VC:N/VI:N/VA:N plus SA:H) and our independent assessment (AV:N/AC:L/PR:N/UI:N/S:U with C:N/I:N/A:H) agree that the attacker gains no code execution, no data read/write, and no influence over the control or I/O functions - only the availability of the web management plane and, subsequently, its dependent workflows. No specific protocol library, HTTP framework, or firmware component is identified in the supplied intelligence, and no CPE strings were provided to narrow the exact affected models; the referenced Rockwell trust-center advisory (SD1757) is the authoritative source for the precise device families and firmware revisions.

Know when Rockwell Automation gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (rockwellautomation) PRIMARY 7.7 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:N/SI:N/SA:H
vuln.today AI 7.5 HIGH

Remote unauthenticated request flood with low complexity (AV:N/AC:L/PR:N/UI:N); only availability of the web server is lost (A:H), with no confidentiality or integrity impact and no scope change.

3.1 AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
4.0 AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (rockwellautomation).

CVSS VectorVendor: rockwellautomation

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
None
Vulnerable system: Integrity
None
Vulnerable system: Availability
None
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
High

DescriptionCVE.org

A denial-of-service security issue exists in the affected product and version. The security issue stems from a high number of requests sent to the web server. This could result in a web server crash however; this does not impact I/O control or communication . A power cycle is required to recover and utilize the webpage.

Executive ViewAI

Why It Matters

Rockwell Automation devices with an embedded web server can be crashed by a flood of network requests, resulting in loss of web-based monitoring and configuration access while I/O control and communications continue to operate normally. The impact on the business is operational rather than safety-related but still material: restoring the affected unit's web interface requires an on-site physical power cycle, which means dispatch costs and monitoring blind spots at remote or unmanned sites. Leadership should care because no vendor patch is currently available, so exposure is reduced only through network controls over the affected Rockwell fleet.

Business Impact: Medium
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations: restrict network access to the embedded web server using firewall rules and OT network segmentation so only trusted management hosts can reach it; deploy rate limiting or connection throttling at the perimeter to blunt request floods; disable the embedded web server on devices where it is not required; monitor for high-volume request patterns against affected devices; and pre-arrange physical or remote-hands access to power cycle units at remote or unmanned sites if the web interface becomes unresponsive.

Threat Intelligence Overview

EPSS Score
0.3%
Top 77% exploitable
Prevalence
Low
Rockwell Automation OT/ICS device, industry-specific footprint; exact product unnamed
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.3%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact
Medium

Priority Score

38
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +38
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Denial of Service attacks render applications or systems unavailable by overwhelming resources or triggering failure conditions.

CVE-2025-13036 CRITICAL POC
9.2 Jun 16

Authentication bypass in Rockwell Automation FactoryTalk Historian Site Edition allows remote attackers to obtain a vali

CVE-2025-11698 CRITICAL
9.2 Jul 14

Denial-of-service in Rockwell Automation CompactLogix/GuardLogix 5380, CompactLogix 5480, and ControlLogix/GuardLogix 55

CVE-2025-12012 CRITICAL
9.2 Jul 14

Denial-of-service in Rockwell Automation Logix programmable controllers allows a remote unauthenticated attacker to writ

CVE-2025-12011 CRITICAL
9.2 Jul 14

Remote denial-of-service in Rockwell Automation CompactLogix 5370, Compact GuardLogix 5370, ControlLogix 5570, and Guard

CVE-2026-0647 HIGH
8.8 Jun 16

Unauthenticated password change in Rockwell Automation 1794-AENTR Flex I/O EtherNet/IP adapter's embedded web server all

CVE-2026-10714 HIGH
8.8 Jul 14

Authentication bypass in Rockwell Automation FactoryTalk Services Platform (FTSP) lets an authenticated low-privilege us

CVE-2026-0646 HIGH
8.7 Jun 16

Denial-of-service in Rockwell Automation 1794-AENTR FLEX I/O EtherNet/IP adapters allows remote unauthenticated attacker

CVE-2026-11317 HIGH
8.7 Jun 16

Remote denial of service in Rockwell Automation CompactLogix and ControlLogix programmable automation controllers allows

CVE-2026-12659 HIGH
8.7 Jul 14

Remote denial-of-service in the Rockwell Automation FLEX 5000 EtherNet/IP adapter allows an unauthenticated network atta

CVE-2026-9140 HIGH
8.7 Jul 14

Denial-of-service in the Rockwell Automation 1719-AENTR (and companion 1718-AENTR) EtherNet/IP adapter allows remote att

CVE-2025-11694 HIGH
8.7 Jun 16

Denial-of-service in Rockwell Automation 1769 CompactLogix 5370 controllers allows remote unauthenticated attackers to i

CVE-2025-12768 HIGH
8.6 Sep 01

Remote code execution in Rockwell Automation FactoryTalk® Historian Machine Edition allows an adjacent-network attacker

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy