Skip to main content

Ac15 Firmware CVE-2025-5850

| EUVDEUVD-2025-17414 HIGH
Buffer Overflow (CWE-119)
2025-06-08 cna@vuldb.com
8.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

4
EUVD ID Assigned
Mar 14, 2026 - 19:17 euvd
EUVD-2025-17414
Analysis Generated
Mar 14, 2026 - 19:17 vuln.today
PoC Detected
Jun 09, 2025 - 19:04 vuln.today
Public exploit code
CVE Published
Jun 08, 2025 - 23:15 nvd
HIGH 8.8

DescriptionCVE.org

A vulnerability was found in Tenda AC15 15.03.05.19_multi. It has been declared as critical. This vulnerability affects the function formsetschedled of the file /goform/SetLEDCf of the component HTTP POST Request Handler. The manipulation of the argument Time leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

AnalysisAI

Critical buffer overflow vulnerability in Tenda AC15 firmware version 15.03.05.19_multi affecting the HTTP POST request handler's LED configuration function. An authenticated remote attacker can exploit improper input validation on the 'Time' parameter to achieve buffer overflow, leading to complete system compromise including confidentiality, integrity, and availability violations. Public exploit code has been disclosed and the vulnerability meets criteria for active exploitation risk.

Technical ContextAI

The vulnerability exists in the formsetschedled function of the /goform/SetLEDCf HTTP POST handler in Tenda AC15 wireless router firmware. This represents a classic CWE-119 (Improper Restriction of Operations within the Bounds of a Memory Buffer) condition where user-supplied input on the 'Time' parameter is not properly validated before being written to a fixed-size buffer. Tenda AC15 devices use embedded HTTP servers to handle router configuration requests; the vulnerable endpoint processes LED scheduling parameters without adequate bounds checking. The CPE context implies this affects Tenda AC15 devices running firmware version 15.03.05.19_multi or potentially other 15.03.05.x releases. The HTTP POST request handler is a core component of the web-based management interface, making this remotely exploitable from the network.

CVE-2025-25632 CRITICAL POC
9.8 Mar 05

Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. Rated critical se

CVE-2026-24105 CRITICAL POC
9.8 Mar 02

Tenda AC15 router has a code injection in formsetUsbUnload (EPSS 1.7%) enabling unauthenticated remote code execution.

CVE-2026-24101 CRITICAL POC
9.8 Mar 02

Tenda AC15 router has a command injection in formSetIptv (EPSS 1.1%) enabling unauthenticated root-level code execution.

CVE-2026-24103 CRITICAL POC
9.8 Mar 03

Buffer overflow in Tenda AC15V1.0 via formSetMacFilterCfg. PoC available.

CVE-2024-2855 CRITICAL POC
9.8 Mar 24

A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Rated critical severity

CVE-2024-2852 CRITICAL POC
9.8 Mar 24

A vulnerability was found in Tenda AC15 15.03.20_multi. Rated critical severity (CVSS 9.8), this vulnerability is remote

CVE-2024-2851 CRITICAL POC
9.8 Mar 24

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. Rated critical severity (CVSS 9.8), this vulnerabili

CVE-2024-2850 CRITICAL POC
9.8 Mar 24

A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Rated critical severity (CVSS 9.8), this

CVE-2024-2815 CRITICAL POC
9.8 Mar 22

A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Rated critical severity (CVSS 9.8),

CVE-2024-2814 CRITICAL POC
9.8 Mar 22

A vulnerability was found in Tenda AC15 15.03.20_multi. Rated critical severity (CVSS 9.8), this vulnerability is remote

CVE-2024-2813 CRITICAL POC
9.8 Mar 22

A vulnerability was found in Tenda AC15 15.03.20_multi. Rated critical severity (CVSS 9.8), this vulnerability is remote

CVE-2024-2811 CRITICAL POC
9.8 Mar 22

A vulnerability was found in Tenda AC15 15.03.20_multi and classified as critical. Rated critical severity (CVSS 9.8), t

Share

CVE-2025-5850 vulnerability details – vuln.today