Skip to main content

Ac15 Firmware CVE-2025-5849

| EUVDEUVD-2025-17415 HIGH
Buffer Overflow (CWE-119)
2025-06-08 cna@vuldb.com
8.8
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, buffer size validation
MITRE ATT&CK

2 techniques across 2 tactics: Execution, Privilege Escalation

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS 8.8. EPSS 0.2%. Public PoC/exploit available. No patch confirmed.

Exploit ScenarioDerived

An attacker could exploit this vulnerability in A vulnerability to compromise the security of affected deployments, potentially impacting confidentiality, integrity, or availability.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 14, 2026

A buffer overflow vulnerability in A vulnerability (CVSS 8.8). Risk factors: public PoC available.

Earlier versions of this analysis (1)
v1 Mar 14, 2026 - 19:17 CVSS 8.8

A vulnerability was found in Tenda AC15 15.03.05.19_multi. It has been classified as critical. This affects the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP

RemediationAI

Monitor vendor channels for patch availability. Consider network segmentation to limit exposure if patching is delayed.

Affected VersionsENISA

AC15 15.03.05.19_multi

Affected Packages

euvd ac15 no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

CWE-119 (Buffer Overflow). CVSS 8.8 indicates high severity. Affects A vulnerability.

Know when Ac15 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

2
PoC Detected
Jun 09, 2025 - 19:04 vuln.today
Public exploit code
CVE Published
Jun 08, 2025 - 23:15 nvd
HIGH 8.8

DescriptionCVE.org

A vulnerability was found in Tenda AC15 15.03.05.19_multi. It has been classified as critical. This affects the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Executive ViewAI

Why It Matters

A critical remote code execution vulnerability affects Tenda AC15 routers (version 15.03.05.19_multi) with a public exploit available, potentially allowing attackers to compromise network infrastructure without authentication. Organizations using this device model face immediate risk of unauthorized access, data theft, and network disruption, particularly concerning given the lack of available patches.

Business Impact: High
Compensating Controls

Disable HTTP remote web management feature (formSetSafeWanWebMan) if operationally feasible; implement Web Application Firewall (WAF) rules to block POST requests to /goform/SetRemoteWebCfg with suspicious remoteIp parameter values; segment affected devices behind restrictive firewall rules with deny-by-default ingress policies; monitor for exploitation attempts via IDS/IPS; isolate device management to dedicated administrative network with VPN-only access.

Threat Intelligence Overview

EPSS Score
0.2%
Top 56% exploitable
Exploit
POC
Public exploit code exists
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC Yes
EPSS 0.2%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
No
Human Impact
High

Priority Score

64
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +44
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

CVE-2025-25632 CRITICAL POC
9.8 Mar 05

Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. Rated critical se

CVE-2026-24105 CRITICAL POC
9.8 Mar 02

Tenda AC15 router has a code injection in formsetUsbUnload (EPSS 1.7%) enabling unauthenticated remote code execution.

CVE-2026-24101 CRITICAL POC
9.8 Mar 02

Tenda AC15 router has a command injection in formSetIptv (EPSS 1.1%) enabling unauthenticated root-level code execution.

CVE-2026-24103 CRITICAL POC
9.8 Mar 03

Buffer overflow in Tenda AC15V1.0 via formSetMacFilterCfg. PoC available.

CVE-2024-2855 CRITICAL POC
9.8 Mar 24

A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Rated critical severity

CVE-2024-2852 CRITICAL POC
9.8 Mar 24

A vulnerability was found in Tenda AC15 15.03.20_multi. Rated critical severity (CVSS 9.8), this vulnerability is remote

CVE-2024-2851 CRITICAL POC
9.8 Mar 24

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. Rated critical severity (CVSS 9.8), this vulnerabili

CVE-2024-2850 CRITICAL POC
9.8 Mar 24

A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Rated critical severity (CVSS 9.8), this

CVE-2024-2815 CRITICAL POC
9.8 Mar 22

A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Rated critical severity (CVSS 9.8),

CVE-2024-2814 CRITICAL POC
9.8 Mar 22

A vulnerability was found in Tenda AC15 15.03.20_multi. Rated critical severity (CVSS 9.8), this vulnerability is remote

CVE-2024-2813 CRITICAL POC
9.8 Mar 22

A vulnerability was found in Tenda AC15 15.03.20_multi. Rated critical severity (CVSS 9.8), this vulnerability is remote

CVE-2024-2811 CRITICAL POC
9.8 Mar 22

A vulnerability was found in Tenda AC15 15.03.20_multi and classified as critical. Rated critical severity (CVSS 9.8), t

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy