Sinec Ins
CVE-2024-46894
MEDIUM
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V14 - Data Protection Data exposure prevention
MITRE ATT&CK
2 techniques across 2 tactics: Collection, Discovery The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 5.3 (MEDIUM). Attack characteristics: network attack vector, low complexity, low privileges required, no user interaction not required. |
| Exploit ScenarioDerived | A remote attacker could access sensitive data that should not be disclosed by sending crafted requests to the affected application. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Minimize information in error messages, implement proper access controls, encrypt sensitive data at rest and in transit.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Exposure of Sensitive Information (CWE-200), which allows attackers to access sensitive data that should not be disclosed. A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly validate authorization of a user to query the "/api/sftp/users" endpoint. This could allow an authenticated remote attacker to gain knowledge about the list of configured users of the SFTP service and also modify that configuration. Affected products include: Siemens Sinec Ins.
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N
Primary rating from Vendor (siemens) · only source for this CVE.
CVSS VectorVendor: siemens
DescriptionCVE.org
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly validate authorization of a user to query the "/api/sftp/users" endpoint. This could allow an authenticated remote attacker to gain knowledge about the list of configured users of the SFTP service and also modify that configuration.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Affected Products (CPE)CVE.org
In addition to the c_rehash shell command injection identified in CVE-2022-1292, further circumstances where the c_rehas
Lodash versions prior to 4.17.21 are vulnerable to Command Injection via the template function. Rated high severity (CVS
When sending data to an MQTT server, libcurl <= 7.73.0 and 7.78.0 could in some circumstances erroneously keep a pointer
A weak randomness in WebCrypto keygen vulnerability exists in Node.js 18 due to a change with EntropySource() in SecretK
json-c through 0.14 has an integer overflow and out-of-bounds write via a large JSON file, as demonstrated by printbuf_m
axios is vulnerable to Inefficient Regular Expression Complexity. Rated high severity (CVSS 7.5), this vulnerability is
The package ua-parser-js before 0.7.23 are vulnerable to Regular Expression Denial of Service (ReDoS) in multiple regexe
In ISC DHCP 4.1-ESV-R1 -> 4.1-ESV-R16, ISC DHCP 4.4.0 -> 4.4.2 (Other branches of ISC DHCP (i.e., releases in the 4.0.x
Authenticated command injection in Siemens SINEC INS versions prior to V1.0 SP2 Update 6 allows remote attackers to exec
Local privilege escalation in Siemens SINEC INS (versions prior to V1.0 SP2 Update 6) stems from a binary shipped with t
The llhttp parser in the http module in Node v18.7.0 does not correctly handle header fields that are not terminated wit
The llhttp parser <v14.20.1, <v16.17.1 and <v18.9.1 in the http module in Node.js does not correctly handle multi-line T
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB