Ac500 Firmware
CVE-2024-32314
LOW
Severity by source
AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:N
Primary rating from Vendor (mitre) · only source for this CVE.
CVSS VectorVendor: mitre
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:N
Lifecycle Timeline
1DescriptionCVE.org
Tenda AC500 V2.0.1.9(1307) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.
AnalysisAI
Tenda AC500 V2.0.1.9(1307) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter. Rated low severity (CVSS 3.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified as Command Injection (CWE-77), which allows attackers to inject arbitrary commands into system command execution. Tenda AC500 V2.0.1.9(1307) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter. Affected products include: Tenda Ac500 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use parameterized APIs, avoid shell execution, validate input with strict allowlists.
More in Ac500 Firmware
View allTenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo fun
A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Rated critical severity (CVSS 9.8),
A vulnerability was found in Tenda AC500 2.0.1.9(1307). Rated critical severity (CVSS 9.8), this vulnerability is remote
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromAddressNat via parameters entrys and mitInte
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromRouteStatic via parameters entrys and mitInt
A buffer overflow vulnerability in A vulnerability (CVSS 8.8). Risk factors: public PoC available.
A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Rated high severity (CVS
A vulnerability was found in Tenda AC500 2.0.1.9(1307). Rated high severity (CVSS 8.8), this vulnerability is remotely e
A vulnerability was found in Tenda AC500 2.0.1.9(1307). Rated high severity (CVSS 8.8), this vulnerability is remotely e
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function formOneSsidCfgSet via parameter ssid. Rated high
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function. Rated medium
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone
Same weakness CWE-77 – Command Injection