Ac7 Firmware
CVE-2024-2903
HIGH
Vulnerability Assessment
| Weakness |
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Stack buffer bounds checking
MITRE ATT&CK
1 technique across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 8.8 (HIGH). Attack characteristics: network attack vector, low complexity, low privileges required, no user interaction not required. Public proof-of-concept exploit code is available. |
| Exploit ScenarioDerived | This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the high-severity affected system. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
A vulnerability was found in Tenda AC7 15.03.06.44. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified under CWE-121. A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Affected products include: Tenda Ac7 Firmware.
Know when Ac7 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
A stack-based buffer overflow occurs when a program writes more data to a buffer located on the stack than it was allocated to hold.
Affected Products (CPE)NVD
More in Ac7 Firmware
View allTenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set f
Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle fun
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to co
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeC
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to co
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasi
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parame
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28,
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0
NVD
CVE.org
EPSS
GitHub
VulDB
Exploit-DB