Ac18 Firmware
CVE-2024-2558
HIGH
Vulnerability Assessment
| Weakness |
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Stack buffer bounds checking
MITRE ATT&CK
1 technique across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 8.8 (HIGH). Attack characteristics: network attack vector, low complexity, low privileges required, no user interaction not required. |
| Exploit ScenarioDerived | This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the high-severity affected system. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
A vulnerability was found in Tenda AC18 15.03.05.05. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified under CWE-121. A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Affected products include: Tenda Ac18 Firmware.
Know when Ac18 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
A stack-based buffer overflow occurs when a program writes more data to a buffer located on the stack than it was allocated to hold.
Affected Products (CPE)NVD
More in Ac18 Firmware
View allTenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId paramet
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId paramet
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function.
Tenda AC18 V15.03.05.05 contains a command injection vulnerablility in the deviceName parameter of formsetUsbUnload func
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Rated critical severity (CVSS 9.8), thi
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the page parameter of fromNatStaticSetting function. Rated
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function. Rated critic
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function. Rat
Tenda AC18 v15.03.05.19(6318_)_cn was discovered to contain a command injection vulnerability via the deviceName paramet
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/formWifiBasicSet. Rated critical severity (CVSS 9.8
Tenda AC18 V15.03.05.19(6318) was discovered to contain a stack overflow via the time parameter in the fromSetSysTime fu
Tenda AC18 router contained a stack overflow vulnerability in /goform/fast_setting_wifi_set. Rated critical severity (CV
NVD
CVE.org
EPSS
GitHub
VulDB