Skip to main content
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V7 - Session Management Session expiration enforcement
Impact

CVSS score of 7.2 (HIGH). Attack characteristics: network attack vector, low complexity, high privileges required, no user interaction not required.

Exploit ScenarioDerived

This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the high-severity affected system.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.5% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

When BIG-IP is deployed in high availability (HA) and an iControl REST API token is updated, the change does not sync to the peer device. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified under CWE-613. When BIG-IP is deployed in high availability (HA) and an iControl REST API token is updated, the change does not sync to the peer device. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated Affected products include: F5 Big-Ip Access Policy Manager, F5 Big-Iq Centralized Management, F5 Big-Ip Advanced Firewall Manager, F5 Big-Ip Analytics, F5 Big-Ip Application Acceleration Manager.

Know when Big Ip Application Security Manager gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 7.2 HIGH
AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
High
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionNVD

When BIG-IP is deployed in high availability (HA) and an iControl REST API token is updated, the change does not sync to the peer device.

Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated

Threat Intelligence Overview

EPSS Score
0.5%
Top 61% exploitable
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.5%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

36
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +36
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

Affected Products (CPE)NVD

cpe:2.3:a:f5:big-ip_access_policy_manager:*:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_access_policy_manager:*:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_access_policy_manager:17.1.0:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-iq_centralized_management:*:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_advanced_firewall_manager:*:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_advanced_firewall_manager:*:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_advanced_firewall_manager:17.1.0:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_analytics:*:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_analytics:*:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_analytics:17.1.0:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_application_acceleration_manager:*:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_application_acceleration_manager:*:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_application_acceleration_manager:17.1.0:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_application_security_manager:*:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_application_security_manager:*:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_application_security_manager:17.1.0:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_domain_name_system:*:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_domain_name_system:*:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_domain_name_system:17.1.0:*:*:*:*:*:*:*
cpe:2.3:a:f5:big-ip_fraud_protection_service:*:*:*:*:*:*:*:*
+ 14 more
CVE-2014-6271 CRITICAL POC
9.8 Sep 24

GNU Bash through 4.3 processes trailing strings after function definitions in the values of environment variables, which

CVE-2014-7169 CRITICAL POC
9.8 Sep 25

GNU Bash through 4.3 bash43-025 processes trailing strings after certain malformed function definitions in the values of

CVE-2023-44487 HIGH POC
7.5 Oct 10

Denial of service against HTTP/2 server implementations allows remote unauthenticated attackers to exhaust server resour

CVE-2012-1493 HIGH POC
7.8 Jul 09

F5 BIG-IP appliances 9.x before 9.4.8-HF5, 10.x before 10.2.4, 11.0.x before 11.0.0-HF2, and 11.1.x before 11.1.0-HF3, a

CVE-2015-3628 CRITICAL POC
9.0 Dec 07

The iControl API in F5 BIG-IP LTM, AFM, Analytics, APM, ASM, Link Controller, and PEM 11.3.0 before 11.5.3 HF2 and 11.6.

CVE-2015-7547 HIGH POC
8.1 Feb 18

Multiple stack-based buffer overflows in the (1) send_dg and (2) send_vc functions in the libresolv library in the GNU C

CVE-2014-0196 MEDIUM POC
5.5 May 07

The n_tty_write function in drivers/tty/n_tty.c in the Linux kernel through 3.14.3 does not properly manage tty driver a

CVE-2025-53521 CRITICAL POC
9.3 Oct 15

F5 BIG-IP APM (Access Policy Manager) contains a remote code execution vulnerability triggered by specific malicious tra

CVE-2014-2928 HIGH POC
7.1 May 12

The iControl API in F5 BIG-IP LTM, APM, ASM, GTM, Link Controller, and PSM 10.0.0 through 10.2.4 and 11.0.0 through 11.5

CVE-2016-9244 HIGH POC
7.5 Feb 09

A BIG-IP virtual server configured with a Client SSL profile that has the non-default Session Tickets option enabled may

CVE-2025-20029 HIGH
8.7 Feb 05

F5 BIG-IP contains an authenticated command injection in the iControl REST API and TMOS Shell (tmsh) save command. Authe

CVE-2023-46747 CRITICAL POC
9.8 Oct 26

Undisclosed requests may bypass configuration utility authentication, allowing an attacker with network access to the BI

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy