Hmi 3 Control Panel Firmware
CVE-2021-37164
CRITICAL
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a stack-based buffer overflow.
AnalysisAI
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Out-of-bounds Write (CWE-787), which allows attackers to write data beyond allocated buffer boundaries leading to code execution or crashes. A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a stack-based buffer overflow. Affected products include: Swisslog-Healthcare Hmi-3 Control Panel Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate write boundaries, use memory-safe languages, enable compiler protections (ASLR, stack canaries).
More in Hmi 3 Control Panel Firmware
View allAn insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by releas
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released ver
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released ver
A buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, o
A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released ver
A buffer overflow issue leading to denial of service was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus P
Same weakness CWE-787 – Out-of-bounds Write
View allSame technique Buffer Overflow