Skip to main content

Interactive Graphical Scada System CVE-2021-22762

HIGH
Path Traversal (CWE-22)
2021-06-11 cybersecurity@se.com
7.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
7.8 HIGH
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Attack Vector
Local
Attack Complexity
Low
Privileges Required
None
User Interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Jun 11, 2021 - 16:15 nvd
HIGH 7.8

DescriptionNVD

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in remote code execution, when a malicious CGF or WSP file is being parsed by IGSS Definition.

AnalysisAI

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in remote code execution, when a. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Path Traversal (CWE-22), which allows attackers to access files and directories outside the intended path. A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in remote code execution, when a malicious CGF or WSP file is being parsed by IGSS Definition. Affected products include: Schneider-Electric Interactive Graphical Scada System.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate and canonicalize file paths. Use chroot or sandboxing. Reject input containing path separators or '../' sequences.

CVE-2013-0657 CRITICAL POC
10.0 Jan 21

Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote

CVE-2017-6033 HIGH
7.8 Apr 07

A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 1

CVE-2023-4516 HIGH
7.8 Sep 14

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update Service that could allow

CVE-2021-22761 HIGH
7.8 Jun 11

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definitio

CVE-2021-22760 HIGH
7.8 Jun 11

A CWE-763: Release of invalid pointer or reference vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and pr

CVE-2021-22759 HIGH
7.8 Jun 11

A CWE-416: Use after free vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in

CVE-2021-22758 HIGH
7.8 Jun 11

A CWE-824: Access of uninitialized pointer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that

CVE-2021-22757 HIGH
7.8 Jun 11

A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result

CVE-2021-22756 HIGH
7.8 Jun 11

A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result

CVE-2021-22755 HIGH
7.8 Jun 11

A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could resul

CVE-2021-22754 HIGH
7.8 Jun 11

A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could resul

CVE-2021-22753 HIGH
7.8 Jun 11

A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result

Share

CVE-2021-22762 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy