Skip to main content

Verizon CVE-2019-3916

HIGH
Direct Request ('Forced Browsing') (CWE-425)
2019-04-11 vulnreport@tenable.com
7.5
CVSS 3.0 · NVD
Share

Severity by source

NVD PRIMARY
7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

Lifecycle Timeline

1
CVE Published
Apr 11, 2019 - 15:29 nvd
HIGH 7.5

DescriptionNVD

Information disclosure vulnerability in Verizon Fios Quantum Gateway (G1100) firmware version 02.01.00.05 allows an remote, unauthenticated attacker to retrieve the value of the password salt by simply requesting an API URL in a web browser (e.g. /api).

AnalysisAI

Information disclosure vulnerability in Verizon Fios Quantum Gateway (G1100) firmware version 02.01.00.05 allows an remote, unauthenticated attacker to retrieve the value of the password salt by. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-425. Information disclosure vulnerability in Verizon Fios Quantum Gateway (G1100) firmware version 02.01.00.05 allows an remote, unauthenticated attacker to retrieve the value of the password salt by simply requesting an API URL in a web browser (e.g. /api). Affected products include: Verizon Fios Quantum Gateway G1100 Firmware. Version information: version 02.01.00.05.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

CVE-2022-28375 CRITICAL POC
9.8 Jul 14

Verizon 5G Home LVSKIHP OutDoorUnit (ODU) 3.33.101.0 does not property sanitize user-controlled parameters within the cr

CVE-2022-28373 CRITICAL POC
9.8 Jul 14

Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 does not properly sanitize user-controlled parameters within the crt

CVE-2022-28369 CRITICAL POC
9.8 Jul 14

Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 does not validate the user-provided URL within the crtcmode function

CVE-2022-28374 HIGH POC
8.8 Jul 14

Verizon 5G Home LVSKIHP OutDoorUnit (ODU) 3.33.101.0 does not property sanitize user-controlled parameters within the DM

CVE-2022-28376 HIGH POC
8.1 Apr 03

Verizon 5G Home LVSKIHP outside devices through 2022-02-15 allow anyone (knowing the device's serial number) to access a

CVE-2022-28377 HIGH POC
7.5 Jul 14

On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC en

CVE-2022-28372 HIGH POC
7.5 Jul 14

On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC en

CVE-2022-28371 HIGH POC
7.5 Jul 14

On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC en

CVE-2022-28370 HIGH POC
7.5 Jul 14

On Verizon 5G Home LVSKIHP OutDoorUnit (ODU) 3.33.101.0 devices, the RPC endpoint crtc_fw_upgrade provides a means of pr

CVE-2022-29729 HIGH POC
7.5 Jun 02

Verizon 4G LTE Network Extender GA4.38 - V0.4.038.2131 utilizes a weak default admin password generation algorithm which

CVE-2019-3914 HIGH POC
7.2 Apr 11

Remote command injection vulnerability in Verizon Fios Quantum Gateway (G1100) firmware version 02.01.00.05 allows a rem

CVE-2013-0126 MEDIUM POC
6.8 Mar 21

Multiple cross-site request forgery (CSRF) vulnerabilities in index.cgi on the Verizon FIOS Actiontec MI424WR-GEN3I rout

Share

CVE-2019-3916 vulnerability details – vuln.today