Verizon
CVE-2022-28376
HIGH
Severity by source
AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
Lifecycle Timeline
1DescriptionNVD
Verizon 5G Home LVSKIHP outside devices through 2022-02-15 allow anyone (knowing the device's serial number) to access a CPE admin website, e.g., at the 10.0.0.1 IP address. The password (for the verizon username) is calculated by concatenating the serial number and the model (i.e., the LVSKIHP string), running the sha256sum program, and extracting the first seven characters concatenated with the last seven characters of that SHA-256 value.
AnalysisAI
Verizon 5G Home LVSKIHP outside devices through 2022-02-15 allow anyone (knowing the device's serial number) to access a CPE admin website, e.g., at the 10.0.0.1 IP address. Rated high severity (CVSS 8.1), this vulnerability is remotely exploitable, no authentication required. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified as Improper Authentication (CWE-287), which allows attackers to bypass authentication mechanisms to gain unauthorized access. Verizon 5G Home LVSKIHP outside devices through 2022-02-15 allow anyone (knowing the device's serial number) to access a CPE admin website, e.g., at the 10.0.0.1 IP address. The password (for the verizon username) is calculated by concatenating the serial number and the model (i.e., the LVSKIHP string), running the sha256sum program, and extracting the first seven characters concatenated with the last seven characters of that SHA-256 value. Affected products include: Verizon Lvskihp Firmware. Version information: through 2022.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Implement multi-factor authentication, enforce strong password policies, use proven authentication frameworks.
Verizon 5G Home LVSKIHP OutDoorUnit (ODU) 3.33.101.0 does not property sanitize user-controlled parameters within the cr
Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 does not properly sanitize user-controlled parameters within the crt
Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 does not validate the user-provided URL within the crtcmode function
Verizon 5G Home LVSKIHP OutDoorUnit (ODU) 3.33.101.0 does not property sanitize user-controlled parameters within the DM
On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC en
On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC en
On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC en
On Verizon 5G Home LVSKIHP OutDoorUnit (ODU) 3.33.101.0 devices, the RPC endpoint crtc_fw_upgrade provides a means of pr
Verizon 4G LTE Network Extender GA4.38 - V0.4.038.2131 utilizes a weak default admin password generation algorithm which
Remote command injection vulnerability in Verizon Fios Quantum Gateway (G1100) firmware version 02.01.00.05 allows a rem
Multiple cross-site request forgery (CSRF) vulnerabilities in index.cgi on the Verizon FIOS Actiontec MI424WR-GEN3I rout
serialize-javascript prior to 3.1.0 allows remote attackers to inject arbitrary code via the function "deleteFunctions"
Same weakness CWE-287 – Improper Authentication
View allSame technique Authentication Bypass
View allShare
External POC / Exploit Code
Leaving vuln.today