Verizon
CVE-2022-28377
HIGH
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V6 - Authentication Password strength requirements
|
| Impact | CVSS score of 7.5 (HIGH). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. Public proof-of-concept exploit code is available. |
| Exploit ScenarioDerived | This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the high-severity affected system. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC endpoints rely on a static account username/password for access control. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified under CWE-521. On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC endpoints rely on a static account username/password for access control. This password can be generated via a binary included in the firmware, after ascertaining the MAC address of the IDU's base Ethernet interface, and adding the string DEVICE_MANUFACTURER='Wistron_NeWeb_Corp.' to /etc/device_info to replicate the host environment. This occurs in /etc/init.d/wnc_factoryssidkeypwd (IDU). Affected products include: Verizon Lvskihp Indoorunit Firmware, Verizon Lvskihp Outdoorunit Firmware.
Know when Verizon gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC endpoints rely on a static account username/password for access control. This password can be generated via a binary included in the firmware, after ascertaining the MAC address of the IDU's base Ethernet interface, and adding the string DEVICE_MANUFACTURER='Wistron_NeWeb_Corp.' to /etc/device_info to replicate the host environment. This occurs in /etc/init.d/wnc_factoryssidkeypwd (IDU).
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Affected Products (CPE)NVD
Verizon 5G Home LVSKIHP OutDoorUnit (ODU) 3.33.101.0 does not property sanitize user-controlled parameters within the cr
Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 does not properly sanitize user-controlled parameters within the crt
Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 does not validate the user-provided URL within the crtcmode function
Verizon 5G Home LVSKIHP OutDoorUnit (ODU) 3.33.101.0 does not property sanitize user-controlled parameters within the DM
Verizon 5G Home LVSKIHP outside devices through 2022-02-15 allow anyone (knowing the device's serial number) to access a
On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC en
On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC en
On Verizon 5G Home LVSKIHP OutDoorUnit (ODU) 3.33.101.0 devices, the RPC endpoint crtc_fw_upgrade provides a means of pr
Verizon 4G LTE Network Extender GA4.38 - V0.4.038.2131 utilizes a weak default admin password generation algorithm which
Remote command injection vulnerability in Verizon Fios Quantum Gateway (G1100) firmware version 02.01.00.05 allows a rem
Multiple cross-site request forgery (CSRF) vulnerabilities in index.cgi on the Verizon FIOS Actiontec MI424WR-GEN3I rout
serialize-javascript prior to 3.1.0 allows remote attackers to inject arbitrary code via the function "deleteFunctions"
NVD
CVE.org
EPSS
GitHub
Exploit-DB