Gs1900 8 Firmware
CVE-2019-15800
CRITICAL
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Due to lack of input validation in the cmd_sys_traceroute_exec(), cmd_sys_arp_clear(), and cmd_sys_ping_exec() functions in the libclicmd.so library contained in the firmware, an attacker could leverage these functions to call system() and execute arbitrary commands on the switches. (Note that these functions are currently not called in this version of the firmware, however an attacker could use other vulnerabilities to finally use these vulnerabilities to gain code execution.)
AnalysisAI
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified as OS Command Injection (CWE-78), which allows attackers to execute arbitrary operating system commands on the host. An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Due to lack of input validation in the cmd_sys_traceroute_exec(), cmd_sys_arp_clear(), and cmd_sys_ping_exec() functions in the libclicmd.so library contained in the firmware, an attacker could leverage these functions to call system() and execute arbitrary commands on the switches. (Note that these functions are currently not called in this version of the firmware, however an attacker could use other vulnerabilities to finally use these vulnerabilities to gain code execution.) Affected products include: Zyxel Gs1900-8 Firmware, Zyxel Gs1900-8Hp Firmware, Zyxel Gs1900-10Hp Firmware, Zyxel Gs1900-16 Firmware, Zyxel Gs1900-24E Firmware. Version information: before 2.50.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Avoid passing user input to shell commands. Use language-specific APIs instead of shell execution. Apply strict input validation with allowlists.
More in Gs1900 8 Firmware
View allAn issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Rated critical severity (CVSS 9.1),
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Rated high severity (CVSS 8.8), thi
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Rated high severity (CVSS 7.5), thi
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Rated high severity (CVSS 7.5), thi
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Rated medium severity (CVSS 5.9), t
Remote code execution in Zyxel GS1900 series managed switches (including GS1900-48HPv2, GS1900-8, GS1900-8HP, GS1900-10H
A vulnerability in the TFTP client of Zyxel GS1900 series firmware, XGS1210 series firmware, and XGS1250 series firmware
A vulnerability in the 'libsal.so' of the Zyxel GS1900 series firmware version 2.60 could allow an authenticated local u
A post-authentication command injection vulnerability in the CGI program in the Zyxel GS1900-48 switch firmware version
An insufficient entropy vulnerability caused by the improper use of a randomness function with low entropy for web authe
ZyXEL NWA1100-N, NWA1100-NH, NWA1121-NI, NWA1123-AC, and NWA1123-NI access points; P-660HN-51, P-663HN-51, VMG1312-B10A,
An insufficient entropy vulnerability caused by the improper use of randomness sources with low entropy for RSA key pair
Same weakness CWE-78 – OS Command Injection