1DescriptionNVD
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Due to lack of input validation in the cmd_sys_traceroute_exec(), cmd_sys_arp_clear(), and cmd_sys_ping_exec() functions in the libclicmd.so library contained in the firmware, an attacker could leverage these functions to call system() and execute arbitrary commands on the switches. (Note that these functions are currently not called in this version of the firmware, however an attacker could use other vulnerabilities to finally use these vulnerabilities to gain code execution.)
AnalysisAI
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified as OS Command Injection (CWE-78), which allows attackers to execute arbitrary operating system commands on the host. An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Due to lack of input validation in the cmd_sys_traceroute_exec(), cmd_sys_arp_clear(), and cmd_sys_ping_exec() functions in the libclicmd.so library contained in the firmware, an attacker could leverage these functions to call system() and execute arbitrary commands on the switches. (Note that these functions are currently not called in this version of the firmware, however an attacker could use other vulnerabilities to finally use these vulnerabilities to gain code execution.) Affected products include: Zyxel Gs1900-8 Firmware, Zyxel Gs1900-8Hp Firmware, Zyxel Gs1900-10Hp Firmware, Zyxel Gs1900-16 Firmware, Zyxel Gs1900-24E Firmware. Version information: before 2.50.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Avoid passing user input to shell commands. Use language-specific APIs instead of shell execution. Apply strict input validation with allowlists.
More in Gs1900 10Hp Firmware
View allAn issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Rated critical severity (CVSS 9.1),
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Rated high severity (CVSS 8.8), thi
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Rated high severity (CVSS 7.5), thi
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Rated high severity (CVSS 7.5), thi
Belkin F9K1102 2 devices with firmware 2.10.17 rely on client-side JavaScript code for authorization, which allows remot
Cisco NX-OS 6.0(2)U6(1) through 6.0(2)U6(5) on Nexus 3000 devices and 6.0(2)A6(1) through 6.0(2)A6(5) and 6.0(2)A7(1) on
The web management interface on Belkin F9K1102 2 devices with firmware 2.10.17 has a blank password, which allows remote
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Rated medium severity (CVSS 5.9), t
Remote code execution in Zyxel GS1900 series managed switches (including GS1900-48HPv2, GS1900-8, GS1900-8HP, GS1900-10H
Cisco Application Policy Infrastructure Controller (APIC) devices with software before 1.0(3h) and 1.1 before 1.1(1j) an
Cross-site request forgery (CSRF) vulnerability on Belkin F9K1102 2 devices with firmware 2.10.17 allows remote attacker
Belkin F9K1102 2 devices with firmware 2.10.17 use an improper algorithm for selecting the ID value in the header of a D
Same weakness CWE-78 – OS Command Injection
View allShare
External POC / Exploit Code
Leaving vuln.today