Honeywell
CVE-2019-13523
MEDIUM
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Lifecycle Timeline
1DescriptionNVD
In Honeywell Performance IP Cameras and Performance NVRs, the integrated web server of the affected devices could allow remote attackers to obtain web configuration data in JSON format for IP cameras and NVRs (Network Video Recorders), which can be accessed without authentication over the network. Affected performance IP Cameras: HBD3PR2,H4D3PRV3,HED3PR3,H4D3PRV2,HBD3PR1,H4W8PR2,HBW8PR2,H2W2PC1M,H2W4PER3,H2W2PER3,HEW2PER3,HEW4PER3B,HBW2PER1,HEW4PER2,HEW4PER2B,HEW2PER2,H4W2PER2,HBW2PER2,H4W2PER3, and HPW2P1. Affected Performance Series NVRs: HEN08104,HEN08144,HEN081124,HEN16104,HEN16144,HEN16184,HEN16204,HEN162244,HEN16284,HEN16304,HEN16384,HEN32104,HEN321124,HEN32204,HEN32284,HEN322164,HEN32304, HEN32384,HEN323164,HEN64204,HEN64304,HEN643164,HEN643324,HEN643484,HEN04103,HEN04113,HEN04123,HEN08103,HEN08113,HEN08123,HEN08143,HEN16103,HEN16123,HEN16143,HEN16163,HEN04103L,HEN08103L,HEN16103L,HEN32103L.
AnalysisAI
In Honeywell Performance IP Cameras and Performance NVRs, the integrated web server of the affected devices could allow remote attackers to obtain web configuration data in JSON format for IP cameras. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Exposure of Sensitive Information (CWE-200), which allows attackers to access sensitive data that should not be disclosed. In Honeywell Performance IP Cameras and Performance NVRs, the integrated web server of the affected devices could allow remote attackers to obtain web configuration data in JSON format for IP cameras and NVRs (Network Video Recorders), which can be accessed without authentication over the network. Affected performance IP Cameras: HBD3PR2,H4D3PRV3,HED3PR3,H4D3PRV2,HBD3PR1,H4W8PR2,HBW8PR2,H2W2PC1M,H2W4PER3,H2W2PER3,HEW2PER3,HEW4PER3B,HBW2PER1,HEW4PER2,HEW4PER2B,HEW2PER2,H4W2PER2,HBW2PER2,H4W2PER3, and HPW2P1. Affected Performance Series NVRs: HEN08104,HEN08144,HEN081124,HEN16104,HEN16144,HEN16184,HEN16204,HEN162244,HEN16284,HEN16304,HEN16384,HEN32104,HEN321124,HEN32204,HEN32284,HEN322164,HEN32304, HEN32384,HEN323164,HEN64204,HEN64304,HEN643164,HEN643324,HEN643484,HEN04103,HEN04113,HEN04123,HEN08103,HEN08113,HEN08123,HEN08143,HEN16103,HEN16123,HEN16143,HEN16163,HEN04103L,HEN08103L,HEN16103L,HEN32103L. Affected products include: Honeywell Hbd3Pr2 Firmware, Honeywell H4D3Prv3 Firmware, Honeywell Hed3Pr3 Firmware, Honeywell H4D3Prv2 Firmware, Honeywell Hbd3Pr1 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Minimize information in error messages, implement proper access controls, encrypt sensitive data at rest and in transit.
An ActiveX control in HscRemoteDeploy.dll in Honeywell Enterprise Buildings Integrator (EBI) R310, R400.2, R410.1, and R
Directory traversal vulnerability in the FTP server on Honeywell Excel Web XL1000C50 52 I/O, XL1000C100 104 I/O, XL1000C
Improper Input Validation vulnerability in Honeywell PM43 on 32 bit, ARM (Printer web page modules) allows Command Injec
Honeywell NVR devices allow remote attackers to create a user account in the admin group by leveraging access to a guest
Honeywell Intermec PM23, PM42, PM43, PC23, PC43, PD43, and PC42 industrial printers before 10.11.013310 and 10.12.x befo
Multiple stack-based buffer overflows in (1) HWOPOSScale.ocx and (2) HWOPOSSCANNER.ocx in Honeywell OPOS Suite before 1.
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB
Unauthenticated access to Honeywell IQ4x building controller HMI. CVSS 10.0.
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-
Controller may be loaded with malicious firmware which could enable remote code execution. Rated critical severity (CVSS
Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. Rated critical severity (CVSS 9.8), this vulnerability
Same weakness CWE-200 – Information Exposure
View allSame technique Information Disclosure
View allShare