Automationworx Software Suite
CVE-2019-12871
HIGH
Severity by source
AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to a Use-After-Free and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project file to be able to manipulate it. After manipulation, the attacker needs to exchange the original file with the manipulated one on the application programming workstation.
AnalysisAI
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Use After Free (CWE-416), which allows attackers to access freed memory to execute arbitrary code or crash the application. An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to a Use-After-Free and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project file to be able to manipulate it. After manipulation, the attacker needs to exchange the original file with the manipulated one on the application programming workstation. Affected products include: Phoenixcontact Automationworx Software Suite. Version information: through 1.86.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use smart pointers or garbage-collected languages. Set pointers to NULL after freeing. Enable memory sanitizers.
Incorrect Permission Assignment for Critical Resource vulnerability in multiple products of the PHOENIX CONTACT classic
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86.
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86.
In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 memory can be read beyond the intended scope due to
In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 manipulated PC Worx or Config+ files could lead to a
Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated re
Same weakness CWE-416 – Use After Free
View allSame technique Use After Free
View allShare
External POC / Exploit Code
Leaving vuln.today