SCADA
CVE-2019-10994
LOW
Vulnerability Assessment
| Weakness |
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, read limits
MITRE ATT&CK
1 technique across 1 tactic: Collection The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 3.3 (LOW). Attack characteristics: local attack vector, low complexity, no privileges required, user interaction required. |
| Exploit ScenarioDerived | A local attacker with access to the system could read data from memory outside the intended buffer boundaries. No authentication is required to exploit this vulnerability. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information. Rated low severity (CVSS 3.3), this vulnerability is no authentication required, low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate array indices and buffer lengths. Use memory-safe languages. Enable AddressSanitizer during testing.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Out-of-bounds Read (CWE-125), which allows attackers to read data from memory outside the intended buffer boundaries. Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information. The attacker must have local access to the system. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N). Affected products include: Laquisscada Scada.
Know when SCADA gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information. The attacker must have local access to the system. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N).
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Affected Products (CPE)NVD
FUXA SCADA has a path traversal vulnerability — ninth critical vulnerability enabling arbitrary file access on SCADA ser
ProficySCADA for iOS 5.0.25920 contains a denial of service vulnerability that allows attackers to crash the application
ScadaApp for iOS 1.1.4.0 contains a denial of service vulnerability that allows attackers to crash the application by in
OS command injection in InSAT MasterSCADA BUK-TS through MMadmServ web interface. Unauthenticated RCE on SCADA managemen
SQL injection in InSAT MasterSCADA BUK-TS through the main web interface. ICS/SCADA system with unauthenticated SQL inje
FUXA SCADA has yet another authorization bypass — now the seventh critical FUXA vulnerability discovered, enabling unaut
FUXA SCADA has an authentication spoofing vulnerability from versions 1.2.8 through 1.2.10 — tenth critical vulnerabilit
FUXA SCADA has insecure default configuration with a known JWT secret — eighth critical vulnerability.
A remote code execution vulnerability in Honeywell Experion PKS and OneWireless WDM (CVSS 9.4). Critical severity with
FUXA SCADA/HMI software has an additional authorization bypass vulnerability enabling unauthenticated access to industri
FUXA SCADA has an eleventh critical vulnerability — missing authorization from versions 1.2.8 onward.
CVE-2025-1727 is a critical vulnerability in RF-based remote linking protocols used for End-of-Train (EoT) and Head-of-T
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB