Skip to main content

SCADA CVE-2019-10994

LOW
Out-of-bounds Read (CWE-125)
2019-08-05 ics-cert@hq.dhs.gov
3.3
CVSS 3.0 · NVD

Severity by source

NVD PRIMARY
3.3 LOW
AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N
Attack Vector
Local
Attack Complexity
Low
Privileges Required
None
User Interaction
Required
Scope
Unchanged
Confidentiality
Low
Integrity
None
Availability
None

Lifecycle Timeline

1
CVE Published
Aug 05, 2019 - 19:15 nvd
LOW 3.3

DescriptionNVD

Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information. The attacker must have local access to the system. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N).

AnalysisAI

Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information. Rated low severity (CVSS 3.3), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Out-of-bounds Read (CWE-125), which allows attackers to read data from memory outside the intended buffer boundaries. Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information. The attacker must have local access to the system. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N). Affected products include: Laquisscada Scada.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate array indices and buffer lengths. Use memory-safe languages. Enable AddressSanitizer during testing.

More in SCADA

View all
CVE-2020-37143 HIGH POC
7.5 Feb 05

ProficySCADA for iOS 5.0.25920 contains a denial of service vulnerability that allows attackers to crash the application

CVE-2019-25349 HIGH POC
7.5 Feb 18

ScadaApp for iOS 1.1.4.0 contains a denial of service vulnerability that allows attackers to crash the application by in

CVE-2026-22553 CRITICAL
9.8 Feb 24

OS command injection in InSAT MasterSCADA BUK-TS through MMadmServ web interface. Unauthenticated RCE on SCADA managemen

CVE-2026-21410 CRITICAL
9.8 Feb 24

SQL injection in InSAT MasterSCADA BUK-TS through the main web interface. ICS/SCADA system with unauthenticated SQL inje

CVE-2026-25893 CRITICAL
9.8 Feb 09

FUXA SCADA has yet another authorization bypass — now the seventh critical FUXA vulnerability discovered, enabling unaut

CVE-2026-25938 CRITICAL
9.8 Feb 09

FUXA SCADA has an authentication spoofing vulnerability from versions 1.2.8 through 1.2.10 — tenth critical vulnerabilit

CVE-2026-25894 CRITICAL
9.8 Feb 09

FUXA SCADA has insecure default configuration with a known JWT secret — eighth critical vulnerability.

CVE-2026-25895 CRITICAL POC
9.8 Feb 09

FUXA SCADA has a path traversal vulnerability — ninth critical vulnerability enabling arbitrary file access on SCADA ser

CVE-2025-2523 CRITICAL
9.4 Jul 10

A remote code execution vulnerability in Honeywell Experion PKS and OneWireless WDM (CVSS 9.4). Critical severity with

CVE-2026-25752 CRITICAL
9.1 Feb 06

FUXA SCADA/HMI software has an additional authorization bypass vulnerability enabling unauthenticated access to industri

CVE-2026-25939 CRITICAL
9.1 Feb 09

FUXA SCADA has an eleventh critical vulnerability — missing authorization from versions 1.2.8 onward.

CVE-2025-1727 HIGH
8.1 Jul 10

CVE-2025-1727 is a critical vulnerability in RF-based remote linking protocols used for End-of-Train (EoT) and Head-of-T

Share

CVE-2019-10994 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy