Skip to main content

SCADA CVE-2019-25349

HIGH
Classic Buffer Overflow (CWE-120)
2026-02-18 disclosure@vulncheck.com
7.5
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Buffer copy size validation
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS 7.5 (HIGH). Attack vector: Network. Complexity: Low. Privileges required: None. User interaction: None. Public exploit/POC available.

Exploit ScenarioDerived

An attacker could exploit this vulnerability to crash the application by inputting an oversized buffer in the Servername field.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.0% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 12, 2026

ScadaApp for iOS 1.1.4.0 contains a denial of service vulnerability that allows attackers to crash the application by inputting an oversized buffer in the Servername field. Attackers can paste a 257-character buffer during login to trigger an application crash on iOS devices. [CVSS 7.5 HIGH]

RemediationAI

Monitor vendor advisories for a patch. Enable ASLR, DEP/NX, and stack canaries where possible. Restrict network access to the affected service where possible.

Affected ProductsAI

ScadaApp for iOS 1.1.4.0 contains a denial of service vulnerability that allows attackers to crash the application by inputting an oversized buffer in

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

Classified as CWE-120 (Classic Buffer Overflow). ScadaApp for iOS 1.1.4.0 contains a denial of service vulnerability that allows attackers to crash the application by inputting an oversized buffer in the Servername field. Attackers can paste a 257-character buffer during login to trigger an application crash on iOS devices.

Know when SCADA gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

Lifecycle Timeline

2
PoC Detected
Feb 19, 2026 - 15:53 vuln.today
Public exploit code
CVE Published
Feb 18, 2026 - 22:16 nvd
HIGH 7.5

DescriptionCVE.org

ScadaApp for iOS 1.1.4.0 contains a denial of service vulnerability that allows attackers to crash the application by inputting an oversized buffer in the Servername field. Attackers can paste a 257-character buffer during login to trigger an application crash on iOS devices.

Executive ViewAI

Why It Matters

ScadaApp for iOS 1.1.4.0 is vulnerable to a denial of service attack that crashes the application when users input oversized text in the login Servername field. Any organization using this application for operational technology monitoring faces service disruption risk, with attackers able to exploit this via public proof-of-concept code.

Business Impact: High
Compensating Controls

Implement network segmentation to limit ScadaApp access to trusted, monitored networks only. Deploy WAF or proxy-based input validation to reject Servername fields exceeding 256 characters. Restrict application usage to authorized personnel only via Mobile Device Management (MDM) policies. Monitor application crash logs for exploitation attempts. Disable remote access to the application until a patch is released. Establish alternative SCADA monitoring procedures as operational backup.

Threat Intelligence Overview

EPSS Score
0.0%
Top 89% exploitable
Exploit
POC
Public exploit code exists
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC Yes
EPSS 0.0%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Out-of-Cycle
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact
High

Priority Score

58
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +38
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Denial of Service attacks render applications or systems unavailable by overwhelming resources or triggering failure conditions.

More in SCADA

View all
CVE-2026-25895 CRITICAL POC
9.8 Feb 09

FUXA SCADA has a path traversal vulnerability — ninth critical vulnerability enabling arbitrary file access on SCADA ser

CVE-2020-37143 HIGH POC
7.5 Feb 05

ProficySCADA for iOS 5.0.25920 contains a denial of service vulnerability that allows attackers to crash the application

CVE-2026-22553 CRITICAL
9.8 Feb 24

OS command injection in InSAT MasterSCADA BUK-TS through MMadmServ web interface. Unauthenticated RCE on SCADA managemen

CVE-2026-21410 CRITICAL
9.8 Feb 24

SQL injection in InSAT MasterSCADA BUK-TS through the main web interface. ICS/SCADA system with unauthenticated SQL inje

CVE-2026-25893 CRITICAL
9.8 Feb 09

FUXA SCADA has yet another authorization bypass — now the seventh critical FUXA vulnerability discovered, enabling unaut

CVE-2026-25938 CRITICAL
9.8 Feb 09

FUXA SCADA has an authentication spoofing vulnerability from versions 1.2.8 through 1.2.10 — tenth critical vulnerabilit

CVE-2026-25894 CRITICAL
9.8 Feb 09

FUXA SCADA has insecure default configuration with a known JWT secret — eighth critical vulnerability.

CVE-2025-2523 CRITICAL
9.4 Jul 10

A remote code execution vulnerability in Honeywell Experion PKS and OneWireless WDM (CVSS 9.4). Critical severity with

CVE-2026-25752 CRITICAL
9.1 Feb 06

FUXA SCADA/HMI software has an additional authorization bypass vulnerability enabling unauthenticated access to industri

CVE-2026-25939 CRITICAL
9.1 Feb 09

FUXA SCADA has an eleventh critical vulnerability — missing authorization from versions 1.2.8 onward.

CVE-2025-1727 HIGH
8.1 Jul 10

CVE-2025-1727 is a critical vulnerability in RF-based remote linking protocols used for End-of-Train (EoT) and Head-of-T

CVE-2021-41579 HIGH
7.8 Oct 04

LCDS LAquis SCADA through 4.3.1.1085 is vulnerable to a control bypass and path traversal. Rated high severity (CVSS 7.8

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy