Skip to main content

V Server CVE-2018-10637

HIGH
Classic Buffer Overflow (CWE-120)
2018-09-13 ics-cert@hq.dhs.gov
7.8
CVSS 3.0 · NVD
Share

Severity by source

NVD PRIMARY
7.8 HIGH
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Attack Vector
Local
Attack Complexity
Low
Privileges Required
None
User Interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Sep 13, 2018 - 19:29 nvd
HIGH 7.8

DescriptionNVD

A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior.

AnalysisAI

A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior. Rated high severity (CVSS 7.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Buffer Copy without Size Check (CWE-120), which allows attackers to overflow a buffer to corrupt adjacent memory. A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior. Affected products include: Fujielectric V-Server.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Always validate buffer sizes before copy operations. Use bounded functions (strncpy, snprintf). Enable compiler protections.

CVE-2019-3947 CRITICAL POC
9.8 Jun 12

Fuji Electric V-Server before 6.0.33.0 stores database credentials in project files as plaintext. Rated critical severit

CVE-2021-22641 HIGH POC
7.8 Jan 27

A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an a

CVE-2019-3946 HIGH POC
7.5 Jun 12

Fuji Electric V-Server before 6.0.33.0 is vulnerable to denial of service via a crafted UDP message sent to port 8005. R

CVE-2019-18240 CRITICAL
9.8 Nov 13

In Fuji Electric V-Server 4.0.6 and prior, several heap-based buffer overflows have been identified, which may allow an

CVE-2023-47586 HIGH
7.8 Nov 15

Multiple heap-based buffer overflow vulnerabilities exist in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0

CVE-2023-47585 HIGH
7.8 Nov 15

Out-of-bounds read vulnerability exists in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0 and earlier. Rated

CVE-2023-47584 HIGH
7.8 Nov 15

Out-of-bounds write vulnerability exists in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0 and earlier. Rate

CVE-2023-31239 HIGH
7.8 Jun 19

Stack-based buffer overflow vulnerability in V-Server v4.0.15.0 and V-Server Lite v4.0.15.0 and earlier allows an attack

CVE-2022-30549 HIGH
7.8 Jun 16

Out-of-bounds read vulnerability exists in V-Server v4.0.11.0 and earlier and V-Server Lite v4.0.13.0 and earlier, which

CVE-2022-29524 HIGH
7.8 Jun 14

Out-of-bounds write vulnerability exists in V-Server v4.0.11.0 and earlier and V-Server Lite v4.0.13.0 and earlier, whic

CVE-2022-29522 HIGH
7.8 Jun 14

Use after free vulnerability exists in the simulator module contained in the graphic editor 'V-SFT' versions prior to v6

CVE-2022-29506 HIGH
7.8 Jun 14

Out-of-bounds read vulnerability exist in the simulator module contained in the graphic editor 'V-SFT' v6.1.3.0 and earl

Share

CVE-2018-10637 vulnerability details – vuln.today