Skip to main content

V Server CVE-2019-3947

CRITICAL
Insufficiently Protected Credentials (CWE-522)
2019-06-12 vulnreport@tenable.com
9.8
CVSS 3.0 · NVD
Share

Severity by source

NVD PRIMARY
9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Jun 12, 2019 - 15:29 nvd
CRITICAL 9.8

DescriptionNVD

Fuji Electric V-Server before 6.0.33.0 stores database credentials in project files as plaintext. An attacker that can gain access to the project file can recover the database credentials and gain access to the database server.

AnalysisAI

Fuji Electric V-Server before 6.0.33.0 stores database credentials in project files as plaintext. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified as Insufficiently Protected Credentials (CWE-522), which allows attackers to obtain user credentials due to weak protection mechanisms. Fuji Electric V-Server before 6.0.33.0 stores database credentials in project files as plaintext. An attacker that can gain access to the project file can recover the database credentials and gain access to the database server. Affected products include: Fujielectric V-Server. Version information: before 6.0.33.0.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Hash passwords with strong algorithms (bcrypt, argon2), encrypt credentials in transit and at rest, never log credentials.

CVE-2021-22641 HIGH POC
7.8 Jan 27

A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an a

CVE-2019-3946 HIGH POC
7.5 Jun 12

Fuji Electric V-Server before 6.0.33.0 is vulnerable to denial of service via a crafted UDP message sent to port 8005. R

CVE-2019-18240 CRITICAL
9.8 Nov 13

In Fuji Electric V-Server 4.0.6 and prior, several heap-based buffer overflows have been identified, which may allow an

CVE-2023-47586 HIGH
7.8 Nov 15

Multiple heap-based buffer overflow vulnerabilities exist in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0

CVE-2023-47585 HIGH
7.8 Nov 15

Out-of-bounds read vulnerability exists in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0 and earlier. Rated

CVE-2023-47584 HIGH
7.8 Nov 15

Out-of-bounds write vulnerability exists in V-Server V4.0.18.0 and earlier and V-Server Lite V4.0.18.0 and earlier. Rate

CVE-2023-31239 HIGH
7.8 Jun 19

Stack-based buffer overflow vulnerability in V-Server v4.0.15.0 and V-Server Lite v4.0.15.0 and earlier allows an attack

CVE-2022-30549 HIGH
7.8 Jun 16

Out-of-bounds read vulnerability exists in V-Server v4.0.11.0 and earlier and V-Server Lite v4.0.13.0 and earlier, which

CVE-2022-29524 HIGH
7.8 Jun 14

Out-of-bounds write vulnerability exists in V-Server v4.0.11.0 and earlier and V-Server Lite v4.0.13.0 and earlier, whic

CVE-2022-29522 HIGH
7.8 Jun 14

Use after free vulnerability exists in the simulator module contained in the graphic editor 'V-SFT' versions prior to v6

CVE-2022-29506 HIGH
7.8 Jun 14

Out-of-bounds read vulnerability exist in the simulator module contained in the graphic editor 'V-SFT' v6.1.3.0 and earl

CVE-2021-38419 HIGH
7.8 Dec 20

Fuji Electric V-Server Lite and Tellus Lite V-Simulator prior to v4.0.12.0 is vulnerable to an out-of-bounds write, whic

Share

CVE-2019-3947 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy