Acselerator Architect
CVE-2018-10600
CRITICAL
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
SEL AcSELerator Architect version 2.2.24.0 and prior allows unsanitized input to be passed to the XML parser, which may allow disclosure and retrieval of arbitrary data, arbitrary code execution (in certain situations on specific platforms), and denial of service attacks.
AnalysisAI
SEL AcSELerator Architect version 2.2.24.0 and prior allows unsanitized input to be passed to the XML parser, which may allow disclosure and retrieval of arbitrary data, arbitrary code execution (in. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as XML External Entity (XXE) (CWE-611), which allows attackers to read arbitrary files or perform SSRF through XML processing. SEL AcSELerator Architect version 2.2.24.0 and prior allows unsanitized input to be passed to the XML parser, which may allow disclosure and retrieval of arbitrary data, arbitrary code execution (in certain situations on specific platforms), and denial of service attacks. Affected products include: Selinc Acselerator Architect. Version information: version 2.2.24.0.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Disable external entity processing in XML parsers, use JSON instead of XML where possible.
More in Acselerator Architect
View allSame technique Denial Of Service
View allShare
External POC / Exploit Code
Leaving vuln.today