M 2001D Digital Tapchanger Control
CVE-2014-9201
MEDIUM
Severity by source
AV:N/AC:L/Au:N/C:P/I:N/A:P
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
AV:N/AC:L/Au:N/C:P/I:N/A:P
Lifecycle Timeline
1DescriptionCVE.org
Beckwith Electric M-6200 Digital Voltage Regulator Control with firmware before D-0198V04.07.00, M-6200A Digital Voltage Regulator Control with firmware before D-0228V02.01.07, M-2001D Digital Tapchanger Control with firmware before D-0214V01.10.04, M-6283A Three Phase Digital Capacitor Bank Control with firmware before D-0346V03.00.02, M-6280A Digital Capacitor Bank Control with firmware before D-0254V03.05.05, and M-6280 Digital Capacitor Bank Control do not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value.
AnalysisAI
Beckwith Electric M-6200 Digital Voltage Regulator Control with firmware before D-0198V04.07.00, M-6200A Digital Voltage Regulator Control with firmware before D-0228V02.01.07, M-2001D Digital. Rated medium severity (CVSS 6.4), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-20. Beckwith Electric M-6200 Digital Voltage Regulator Control with firmware before D-0198V04.07.00, M-6200A Digital Voltage Regulator Control with firmware before D-0228V02.01.07, M-2001D Digital Tapchanger Control with firmware before D-0214V01.10.04, M-6283A Three Phase Digital Capacitor Bank Control with firmware before D-0346V03.00.02, M-6280A Digital Capacitor Bank Control with firmware before D-0254V03.05.05, and M-6280 Digital Capacitor Bank Control do not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value. Affected products include: Beckwithelectric M-2001D Digital Tapchanger Control, Beckwithelectric M-6200 Digital Voltage Regulator Control, Beckwithelectric M-6200A Digital Voltage Regulator Control, Beckwithelectric M-6280 Digital Capacitor Bank Control, Beckwithelectric M-6280A Digital Capacitor Bank Control.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Same weakness CWE-20 – Improper Input Validation
View allSame technique Information Disclosure
View allShare