Proclima
CVE-2014-8514
HIGH
Severity by source
AV:N/AC:L/Au:N/C:P/I:P/A:P
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
AV:N/AC:L/Au:N/C:P/I:P/A:P
Lifecycle Timeline
1DescriptionCVE.org
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers.
AnalysisAI
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, low attack complexity.
Technical ContextAI
This vulnerability is classified as Buffer Overflow (CWE-119), which allows attackers to corrupt memory to execute arbitrary code or crash the application. Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers. Affected products include: Schneider Electric Proclima. Version information: before 6.1.7.
RemediationAI
A vendor patch is available. Apply the latest security update as soon as possible. Use memory-safe languages or bounds-checking. Enable ASLR, DEP/NX, stack canaries. Use safe string functions.
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers
Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers t
A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthen
A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an una
Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 all
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers
Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers t
A CWE-427: Uncontrolled Search Path Element vulnerability exists in ProClima (all versions prior to version 8.0.0) which
The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execu
Same weakness CWE-119 – Buffer Overflow
View allSame technique Buffer Overflow
View allShare
External POC / Exploit Code