Skip to main content

Edimax

Vendor security scorecard – 124 CVEs in the selected period

Period: 30d 90d 6m 1y All
Risk 1405
124
CVEs
16
Critical
56
High
1
KEV
118
PoC
71
Unpatched C/H
0.8%
Patch Rate
2.0%
Avg EPSS

Severity Breakdown

CRITICAL
16
HIGH
56
MEDIUM
13
LOW
39

Monthly CVE Trend

Top Risky CVEs

CVE Summary Severity CVSS EPSS Priority Signals
CVE-2025-1316 Edimax IC-7100 IP camera allows unauthenticated remote code execution through improper neutralization of requests, with no patch available as the device is end-of-life. CRITICAL 9.3 85.1% 182
KEV No patch
CVE-2025-28146 Edimax AC1200 Wave 2 Dual-Band Gigabit Router BR-6478AC V3 1.0.15 was discovered to contain a command injection vulnerability via fota_url in /boafrm/formLtefotaUpgradeQuectel. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and EPSS exploitation probability 19.4%. CRITICAL 9.8 19.4% 88
PoC No patch
CVE-2025-45857 EDIMAX CV7428NS v1.20 was discovered to contain a remote code execution (RCE) vulnerability via the command parameter in the mp function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available. CRITICAL 9.8 4.4% 73
PoC No patch
CVE-2025-22906 RE11S v1.11 was discovered to contain a command injection vulnerability via the L2TPUserName parameter at /goform/setWAN. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available. CRITICAL 9.8 2.2% 71
PoC No patch
CVE-2025-22912 RE11S v1.11 was discovered to contain a command injection vulnerability via the component /goform/formAccept. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available. CRITICAL 9.8 2.2% 71
PoC No patch
CVE-2025-22905 RE11S v1.11 was discovered to contain a command injection vulnerability via the command parameter at /goform/mp. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available. CRITICAL 9.8 1.3% 70
PoC No patch
CVE-2020-37125 Unauthenticated remote code execution via OS command injection in Edimax EW-7438RPn-v3 Mini wireless extender firmware 1.27. EPSS 1.3% with PoC available. CRITICAL 9.8 1.3% 70
PoC No patch
CVE-2025-70161 EDIMAX BR-6208AC V2 router allows command injection through the pppUserName field via system() without sanitization. PoC available. CRITICAL 9.8 0.5% 70
PoC No patch
CVE-2025-22904 RE11S v1.11 was discovered to contain a stack overflow via the pptpUserName parameter in the setWAN function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available. CRITICAL 9.8 0.4% 69
PoC No patch
CVE-2025-22916 RE11S v1.11 was discovered to contain a stack overflow via the pppUserName parameter in the formPPPoESetup function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available. CRITICAL 9.8 0.4% 69
PoC No patch
CVE-2025-22907 RE11S v1.11 was discovered to contain a stack overflow via the selSSID parameter in the formWlSiteSurvey function. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available. CRITICAL 9.8 0.4% 69
PoC No patch
CVE-2023-31985 A Command Injection vulnerability in Edimax Wireless Router N300 Firmware BR-6428NS_v4 allows attacker to execute arbitrary code via the formAccept function in /bin/webs without any limitations. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available. CRITICAL 9.8 8.1% 69
PoC No patch
CVE-2023-31983 A Command Injection vulnerability in Edimax Wireless Router N300 Firmware BR-6428NS_v4 allows attacker to execute arbitrary code via the mp function in /bin/webs without any limitations. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available. CRITICAL 9.8 24.9% 69
PoC No patch
CVE-2023-31986 A Command Injection vulnerability in Edimax Wireless Router N300 Firmware BR-6428NS_v4 allows attacker to execute arbitrary code via the setWAN function in /bin/webs without any limitations. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available. CRITICAL 9.8 8.2% 69
PoC No patch
CVE-2024-48419 Edimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC 1.06 suffers from Command Injection issues in /bin/goahead. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available. HIGH 8.8 3.5% 67
PoC No patch

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy