CVE-2024-48419
HIGHCVSS Vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
3Description
Edimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC 1.06 suffers from Command Injection issues in /bin/goahead. Specifically, these issues can be triggered through /goform/tracerouteDiagnosis, /goform/pingDiagnosis, and /goform/fromSysToolPingCmd Each of these issues allows an attacker with access to the web interface to inject and execute arbitrary shell commands, with "root" privileges.
Analysis
Edimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC 1.06 suffers from Command Injection issues in /bin/goahead. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.
Technical Context
This vulnerability is classified as Command Injection (CWE-77), which allows attackers to inject arbitrary commands into system command execution. Edimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC 1.06 suffers from Command Injection issues in /bin/goahead. Specifically, these issues can be triggered through /goform/tracerouteDiagnosis, /goform/pingDiagnosis, and /goform/fromSysToolPingCmd Each of these issues allows an attacker with access to the web interface to inject and execute arbitrary shell commands, with "root" privileges. Affected products include: Edimax Br-6476Ac Firmware.
Affected Products
Edimax Br-6476Ac Firmware.
Remediation
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use parameterized APIs, avoid shell execution, validate input with strict allowlists.
Priority Score
Share
External POC / Exploit Code
Leaving vuln.today