Br 6476Ac Firmware
CVE-2024-48419
HIGH
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Command injection prevention
MITRE ATT&CK
1 technique across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 8.8 (HIGH). Attack characteristics: network attack vector, low complexity, low privileges required, no user interaction not required. Public proof-of-concept exploit code is available. EPSS exploitation probability: 3.47%. |
| Exploit ScenarioDerived | A remote attacker could inject arbitrary commands into system command execution by sending crafted requests to the affected application. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Mar 28, 2026
Edimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC 1.06 suffers from Command Injection issues in /bin/goahead. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use parameterized APIs, avoid shell execution, validate input with strict allowlists.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Command Injection (CWE-77), which allows attackers to inject arbitrary commands into system command execution. Edimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC 1.06 suffers from Command Injection issues in /bin/goahead. Specifically, these issues can be triggered through /goform/tracerouteDiagnosis, /goform/pingDiagnosis, and /goform/fromSysToolPingCmd Each of these issues allows an attacker with access to the web interface to inject and execute arbitrary shell commands, with "root" privileges. Affected products include: Edimax Br-6476Ac Firmware.
Know when Br 6476Ac Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary rating from Vendor (mitre) · only source for this CVE.
CVSS VectorVendor: mitre
Lifecycle Timeline
2DescriptionCVE.org
Edimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC 1.06 suffers from Command Injection issues in /bin/goahead. Specifically, these issues can be triggered through /goform/tracerouteDiagnosis, /goform/pingDiagnosis, and /goform/fromSysToolPingCmd Each of these issues allows an attacker with access to the web interface to inject and execute arbitrary shell commands, with "root" privileges.
Executive ViewAI
CVE-2024-48419 presents significant security risk, a command injection vulnerability rated CVSS 8.8. Successful exploitation could allow attackers to execute arbitrary code or commands on affected systems, potentially leading to full system compromise. Proof-of-concept code is publicly available, increasing the risk of exploitation. Organizations should apply vendor updates when available and consider compensating controls in the interim.
Apply vendor patch. If immediate patching is not feasible: (1) Deploy WAF rules to block injection patterns; (2) Restrict network access to affected components; (3) Enable enhanced logging for suspicious activity.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
OS command injection occurs when an application passes unsanitized user input directly into system shell commands.
Affected Products (CPE)CVE.org
More in Br 6476Ac Firmware
View allEdimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC 1.06 is vulnerable to Buffer Overflow via /goform/getWifiBasic. Rated h
Edimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC 1.06 is vulnerable to Buffer Overflow via /goform/fromSetLanDhcpsClient
In Edimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC 1.06, the request /goform/fromSetDDNS does not properly handle speci
Edimax AC1200 Wi-Fi 5 Dual-Band Router BR-6476AC 1.06 is vulnerable to Cross Site Scripting (XSS) in : /bin/goahead via
NVD
CVE.org
EPSS
GitHub
Exploit-DB