Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Reach device web service on OT network
  2. Delivery
    Send request with malformed length field
  3. Exploit
    Trigger integer underflow in length validation
  4. Execution
    Force out-of-bounds memory read or crash
  5. Impact
    Leak device memory or cause denial of service

Vulnerability Assessment

Weakness
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Integer underflow checks
Exploitation Conditions

Exploitation requires network reachability to the affected controller's embedded web service; no authentication, no user interaction, and no non-default configuration are needed (AV:N/AC:L/PR:N/UI:N against default web-enabled deployments of Siemens APOGEE PXC/MBC/MEC and TALON TC controllers). The practical limiting factor is network exposure: these are building-automation/OT field controllers normally placed on isolated or segmented management networks, so realistic risk depends heavily on whether the web service is reachable from untrusted hosts. Impact is bounded to memory disclosure and denial of service - there is no confirmed code-execution or integrity-modification path in the available data.

Impact

The vendor-supplied CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:N, base 8.8) describes a network-reachable, low-complexity, unauthenticated flaw in the device web service with high confidentiality impact (VC:H) and low availability impact (VA:L), consistent with the CWE-191 integer-underflow/length-validation root cause that enables out-of-bounds memory reads and crashes. No EPSS score, CISA KEV listing, or public POC is present in the provided data, so there is no public exploit identified at time of analysis and no evidence of active exploitation - the headline 8.8 reflects theoretical reachability, not demonstrated weaponization. The decisive mitigating reality is deployment context: these are Siemens APOGEE/TALON building-automation controllers normally deployed on segmented OT/BMS networks rather than the public internet, which sharply narrows the practical AV:N reach despite the unauthenticated rating. Net assessment: a genuine high-priority patch item for any operator whose controllers are network-reachable to untrusted hosts, but likely a lower real-world risk than 8.8 implies for well-segmented building-automation environments. One caveat: several affected products (APOGEE MBC/MEC PPC variants) are listed as 'All versions' with no fixed version in the input, so remediation availability for those models should be verified against the Siemens advisory.

Exploit ScenarioDerived

An attacker with network access to a controller's web service sends a crafted request whose declared input length is manipulated to trigger the integer-underflow length miscalculation. The resulting out-of-bounds read returns portions of adjacent device memory (potentially leaking sensitive runtime data), or corrupts processing enough to crash the service into a denial-of-service state. No authentication or user interaction is required, but no public exploit code is known at time of analysis.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.5% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv2 – Oct 13, 2026

Unauthenticated remote attackers can read portions of device memory or cause a denial-of-service condition in Siemens APOGEE MBC/MEC and PXC, and TALON TC building controllers through the embedded web service, due to improper length validation of user-controllable input (CWE-191 integer underflow). Affected versions include APOGEE PXC Compact/Modular (BACnet) before V3.5.7 and (P2 Ethernet) before V2.8.21, TALON TC Compact/Modular (BACnet) before V3.5.7, and all versions of APOGEE MBC and MEC. No public exploit has been identified at the time of analysis; the vendor has released patches for the PXC and TALON variants, but no fix is available for MBC/MEC.

Earlier versions of this analysis (1)
v1 Oct 13, 2026 - 10:07 CVSS 8.2

Unauthenticated remote attackers can read portions of device memory or trigger a denial-of-service condition on Siemens APOGEE MBC/MEC (PPC), APOGEE PXC Compact/Modular and TALON TC building automation controllers, because the embedded product web service fails to validate the length of user-controllable input (CWE-191 integer underflow). The issue is rated CVSS v3.1 8.2 (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:L), with the primary impact being memory disclosure and a secondary availability impact. Practical risk depends on whether the controller's HTTP/web service is network-reachable, which OT segmentation usually restricts; fixed firmware exists only for the PXC Compact/Modular and TALON TC lines (V3.5.7 BACnet, V2.8.21 P2 Ethernet), while APOGEE MBC (PPC) and MEC (PPC) are listed as affected in all versions. No public exploit code or confirmed active exploitation was identified at time of analysis, so this is best treated as an OT network-exposure issue rather than a mass-exploitation threat.

RemediationAI

For APOGEE PXC Compact/Modular (BACnet) and TALON TC Compact/Modular (BACnet), upgrade to V3.5.7. For APOGEE PXC Compact/Modular (P2 Ethernet), upgrade to V2.8.21. For APOGEE MBC and MEC (all variants), no vendor-released patch has been identified; apply compensating controls: restrict network access to the embedded web service by placing controllers on isolated OT VLANs and blocking HTTP/HTTPS from untrusted networks, disable the web service if not operationally required (note this may impact remote management), and monitor for anomalous requests. Consult the Siemens advisory at https://cert-portal.siemens.com/productcert/html/ssa-333035.html for updates. No public exploit identified, but unauthenticated network-reachable exploitation is possible.

Affected VersionsENISA

TALON TC Compact (BACnet) 0 <V3.5.7
TALON TC Modular (BACnet) 0 <V3.5.7
APOGEE MBC (PPC) (P2 Ethernet) 0 <*
APOGEE MEC (PPC) (BACnet) 0 <*
APOGEE MEC (PPC) (P2 Ethernet) 0 <*
APOGEE PXC Compact (BACnet) 0 <V3.5.7
APOGEE MBC (PPC) (BACnet) 0 <*
APOGEE PXC Compact (P2 Ethernet) 0 <V2.8.21
APOGEE PXC Modular (BACnet) 0 <V3.5.7
APOGEE PXC Modular (P2 Ethernet) 0 <V2.8.21

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The vulnerability resides in the embedded web service of Siemens APOGEE and TALON building automation controllers, which fails to properly validate the length of user-controllable input. This is a CWE-191 integer underflow: a length field can be decremented below zero and then interpreted as a large unsigned value, leading to out-of-bounds memory reads. The affected products use BACnet or P2 Ethernet protocols for building automation and are managed via a web interface. Per the vendor advisory, an unauthenticated remote attacker with network access to the web service can exploit this to disclose memory contents or crash the service. The independent assessment confirms impact is limited to confidentiality (high) and availability (low), with no integrity or code-execution impact.

Know when Apogee Mbc Ppc Bacnet gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (siemens) PRIMARY 8.8 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:L/SC:N/SI:N/SA:N
vuln.today AI 8.2 HIGH

Web service is network-reachable without auth or interaction (AV:N/AC:L/PR:N/UI:N); memory disclosure gives C:H, no integrity impact (I:N), and the DoS yields only A:L.

3.1 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:L
4.0 AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:L/SC:N/SI:N/SA:N

Primary rating from Vendor (siemens).

CVSS VectorVendor: siemens

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
None
Vulnerable system: Availability
Low
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

2
CVSS changed
Oct 13, 2026 - 10:22 NVD
8.2 (HIGH) 8.8 (HIGH)
CVE Published
Oct 13, 2026 - 09:19 cve.org
HIGH 8.2

DescriptionCVE.org

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The affected product web service does not properly validate the length of user-controllable input. This could allow an unauthenticated remote attacker to read portions of device memory or to cause a denial-of-service condition.

Executive ViewAI

Why It Matters

A high-severity (CVSS 8.8) flaw in the embedded web service of Siemens APOGEE MBC/MEC and PXC and TALON TC building controllers allows a remote attacker to read portions of device memory or crash the device, putting facility HVAC, energy, and environmental control systems at risk of disruption or information disclosure. The exposure is compounded because the APOGEE MBC and MEC product lines have no vendor-released fix at this time, meaning facilities running those models cannot close the gap through patching alone. Leadership should care because these controllers sit in physical building infrastructure, and a successful attack could disrupt occupant comfort and safety systems or expose sensitive operational data across the estate. No public exploit has been identified at the time of analysis.

Business Impact: High
Compensating Controls

Apply vendor patch for APOGEE PXC (BACnet V3.5.7, P2 Ethernet V2.8.21) and TALON TC (BACnet V3.5.7). For APOGEE MBC and MEC, where no vendor-released patch is identified at time of analysis: disable the embedded web service if not required, restrict access to a dedicated management VLAN with firewall rules and allow-listing, avoid exposing controllers to the internet, segment building automation networks from corporate/guest networks, and monitor for anomalous requests against the embedded web service.

Threat Intelligence Overview

EPSS Score
0.5%
Top 62% exploitable
Prevalence
Low
industry-specific Siemens building-automation controllers, niche OT deployment footprint
Social Media
1
Sightings
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.5%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact
High

Priority Score

44
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +44
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0