Skip to main content

Suprema BioStar 2 EUVDEUVD-2026-77158

| CVE-2026-31278 HIGH
Cleartext Transmission of Sensitive Information (CWE-319)
2026-09-14 mitre GHSA-h5qg-wfw7-j3ph
7.7
CVSS 3.1 · Vendor: mitre
Share

Severity by source

Vendor (mitre) PRIMARY
7.7 HIGH
AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N
vuln.today AI
7.7 HIGH

Network-reachable API requiring only low-privilege auth; scope change because returned AD credentials compromise systems beyond BioStar 2; no integrity or availability impact on any system.

3.1 AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N
4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N

Primary rating from Vendor (mitre).

CVSS VectorVendor: mitre

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Changed
Confidentiality
High
Integrity
None
Availability
None

Lifecycle Timeline

3
Patch available
Sep 14, 2026 - 03:01 EUVD
Analysis Generated
Sep 14, 2026 - 02:16 vuln.today
CVE Published
Sep 14, 2026 - 00:00 cve.org
HIGH 7.7

DescriptionCVE.org

An issue in the /api/v2/setting/adserversetting endpoint of Suprema BioStar 2 before 2.9.12 and and BioStar X before 1.0.2 allows attackers to obtain Active Directory service account credentials in cleartext by supplying a crafted GET request.

AnalysisAI

Cleartext credential exposure in Suprema BioStar 2 (before 2.9.12) and BioStar X (before 1.0.2) allows any authenticated API user to retrieve Active Directory service account credentials in plaintext via a single GET request to the /api/v2/setting/adserversetting endpoint. The CVSS scope change (S:C) reflects that the real impact extends far beyond BioStar 2 itself - the exposed AD credentials can grant an attacker access to the entire Windows domain, enabling lateral movement and privilege escalation. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
technique details hidden
Delivery
technique details hidden
Exploit
technique details hidden
Execution
technique details hidden
Impact
technique details hidden

Vulnerability AssessmentAI

Exploitation Requires a valid BioStar 2 user account with at least low-privilege API access (confirmed by PR:L in the provided CVSS vector); no elevated or administrative BioStar 2 role is needed. … Additional conditions and limiting factors are described in the full assessment.
Risk Assessment The CVSS 7.7 score (AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N) is directionally appropriate: the attack is network-reachable, requires only low-privilege authentication, involves no user interaction, and produces a scope change because the returned AD credentials place a system entirely outside BioStar 2 at risk. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario Full exploit scenario with step-by-step reproduction available after sign-in.
Remediation Upgrade Suprema BioStar 2 to version 2.9.12 or later, and BioStar X to version 1.0.2 or later, per vendor guidance at https://www.supremainc.com. … Detailed patch versions, workarounds, and compensating controls in full report.

Recommended ActionAI

Within 24 hours: determine whether BioStar 2 (versions before 2.9.12) or BioStar X (versions before 1.0.2) are deployed and immediately restrict API access to a minimal set of trusted administrators. …

Sign in for detailed remediation steps and compensating controls.

Threat intelligence, references, and detailed analysis are available after sign-in.

Share

EUVD-2026-77158 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy