Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessObtain low-privilege PowerStore account
-
DeliveryAccess management CLI or shell interface
-
ExploitInject OS commands via unsanitized input field
-
ExecutionCommands execute as root
-
ImpactExfiltrate, corrupt, or ransom all hosted storage data
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Command injection prevention
MITRE ATT&CK
1 technique across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Exploitation requires a valid low-privilege authenticated account on the affected Dell PowerStore appliance, consistent with CVSS PR:L. Local access to the appliance management interface or shell environment is required (AV:L) - remote unauthenticated exploitation is not supported by the vector. No user interaction is needed once the authenticated session is established (UI:N), and no race condition or special environmental configuration is required (AC:L). The key limiting factor is the prerequisite of prior local authentication: an attacker must control a valid low-privilege credential before exploitation is possible. No specific non-default configuration is documented as a prerequisite in available data beyond possession of such a credential. |
| Impact | The CVSS 8.8 score is credible: the scope change and full C:H/I:H/A:H triad accurately reflect that root on an enterprise storage appliance is tantamount to unrestricted access to every dataset the array serves. The primary risk-limiting factor is AV:L - this is not a remotely exploitable internet-facing flaw; an attacker must first obtain a local authenticated session, whether through credential theft, misuse of a service or monitoring account, or a prior foothold on an adjacent system with storage management access. EPSS data is not provided in available intelligence, and the vulnerability is not in the CISA KEV catalog, meaning no confirmed active exploitation exists at time of analysis. No public POC has been identified. Even a mid-sized enterprise storage team - the kind managing PowerStore arrays in a regional data center serving dozens of workloads - should treat this as urgent given the privilege escalation potential and the sensitivity of storage infrastructure. The AC:L metric means exploitation is straightforward once the prerequisite local access is obtained, with no race conditions or unusual environmental factors required. Risk is therefore high for environments where limited-privilege shell accounts are granted to multiple staff or automated systems. |
| Exploit ScenarioDerived | An attacker who has obtained a low-privilege account on a Dell PowerStore appliance - through credential theft, misuse of a shared service account, or lateral movement from a compromised management host - submits crafted input containing shell metacharacters to a vulnerable command-handling component. The injected commands bypass the privilege boundary and execute as root, granting full control of the appliance OS, its storage pools, and all hosted data. No public exploit code exists at time of analysis, so exploitation currently requires attacker-developed tooling and prior authenticated local access. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Sep 01, 2026
Command injection in Dell PowerStore storage appliances allows an authenticated low-privileged local user to execute arbitrary operating system commands with root privileges, achieving full appliance compromise. The CVSS scope-change metric (S:C) reflects that root access on a storage platform threatens all data hosted on the array, extending blast radius beyond the appliance itself. No public exploit code has been identified and the vulnerability is not listed in the CISA KEV catalog at time of analysis, but the low attack complexity once local access is established makes this a priority remediation for organizations running affected PowerStore T and Q series hardware.
RemediationAI
Apply the security update detailed in Dell advisory DSA-2026-330, available at https://www.dell.com/support/kbdoc/en-us/000497829/dsa-2026-330-dell-powerstore-t-security-update-for-multiple-vulnerabilities. Patch available per vendor advisory; the exact patched firmware version must be confirmed from that advisory, as no specific fix version is available in current intelligence data. As compensating controls prior to patching, audit all local and management-interface accounts on PowerStore appliances and remove or disable any unnecessary limited-privilege accounts, particularly service or monitoring accounts with shell access. Restrict access to the PowerStore management CLI and UI to a minimal set of trusted administrator accounts, enforced at the network level by isolating storage management VLANs from general-purpose workstation networks. These controls reduce exposure by limiting who can establish the local authenticated session that exploitation requires, though they do not eliminate the underlying vulnerability.
Affected VersionsENISA
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
Dell PowerStore is an enterprise NVMe-based storage platform spanning multiple hardware models. Affected CPEs confirmed by NVD cover the 500T, 1000T, 1200T, 3000T, 3200Q, 3200T, 5000T, 5200Q, 5200T, and 7000T. The vulnerability is CWE-77 (Improper Neutralization of Special Elements Used in a Command), where user-controlled input is passed insufficiently sanitized to a command interpreter - typically a POSIX shell - allowing injection of additional commands via metacharacters such as semicolons, pipes, or backticks. The CVSS vector AV:L confirms that exploitation is constrained to local access (shell or management CLI), while PR:L indicates that a limited-privilege account is sufficient. The scope change (S:C) is particularly significant in a storage context: root-level compromise of a PowerStore node gives an attacker full control over the PowerStoreOS environment, storage pools, replication configuration, and all block and file data hosted on the platform.
Know when Powerstore 500T gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Local low-privilege account escalates to root via command injection with scope change, granting full appliance control; no user interaction or elevated preconditions beyond authenticated local access.
Primary rating from Vendor (dell).
CVSS VectorVendor: dell
Lifecycle Timeline
2DescriptionCVE.org
Dell PowerStore contains a Command Injection vulnerability. An authenticated user with limited privileges could potentially exploit this vulnerability to execute arbitrary commands with root privileges.
Executive ViewAI
Dell PowerStore storage appliances (T and Q series) contain a critical command injection flaw allowing authenticated local users to escalate to root access and compromise all data on the affected arrays. No patch is currently available, leaving organizations vulnerable until vendor resolution. Immediate action to restrict local access and audit user privileges is essential to prevent data exposure.
No vendor-released patch identified at time of analysis. Implement interim mitigations: enforce network segmentation and access controls limiting local connectivity to authorized administrative interfaces, audit and remove unnecessary local user accounts, apply principle of least privilege to remaining local accounts, enable storage appliance logging and alerting for injection attack signatures, and maintain offline backup copies of critical data hosted on affected arrays.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
OS command injection occurs when an application passes unsanitized user input directly into system shell commands.
More in Powerstore 500T
View allRemote code execution and denial of service in Dell PowerStore T-series arrays (SDNAS software) stem from an out-of-boun
Unauthenticated information disclosure in Dell PowerStore T-series storage appliances allows an attacker with network ac
OS command injection in Dell PowerStore storage appliances enables a locally authenticated user with limited privileges
Privilege escalation in Dell PowerStore storage appliances allows any authenticated low-privilege user to bypass access
Privilege escalation to Administrator level is possible on Dell PowerStore storage appliances through an authentication
Privilege escalation in Dell PowerStore storage appliances allows an authenticated low-privilege user to invoke administ
Privilege escalation in Dell PowerStore enterprise storage appliances allows authenticated low-privileged users to bypas
Elevation of privilege in Dell PowerStore storage appliances allows a remote, low-privileged attacker to bypass authoriz
Code injection in Dell PowerStore storage appliances (500T through 7000T series and potentially additional models) allow
Privilege escalation to root on Dell PowerStore storage appliances allows an authenticated user with limited privileges
Buffer overflow in Dell PowerStore SDNAS's NFS/RPC subsystem exposes the entire PowerStore appliance line (500T through
Missing authorization enforcement in Dell PowerStore storage appliances allows any attacker who has gained control of a
EUVD-2026-69299
GHSA-2r72-j89f-5c3v
NVD
CVE.org
EPSS
Vulnrichment
Exploit-DB