Skip to main content

Splunk Connect for Kafka EUVDEUVD-2026-62968

| CVE-2026-76403 HIGH
Improper Certificate Validation (CWE-295)
2026-08-19 cisco GHSA-xf48-ph6x-76rj
7.4
CVSS 3.1 · Vendor: cisco
Share

Severity by source

Vendor (cisco) PRIMARY
7.4 HIGH
AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
vuln.today AI
7.4 HIGH

Network vector and PR:N are correct as attacker is passive MitM; AC:H reflects mandatory network-path positioning; no availability impact applies.

3.1 AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
4.0 AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:H/SA:N

Primary rating from Vendor (cisco).

CVSS VectorVendor: cisco

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
Attack Vector
Network
Attack Complexity
High
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
None

Lifecycle Timeline

3
Analysis Generated
Aug 19, 2026 - 22:18 vuln.today
Patch available
Aug 19, 2026 - 22:04 EUVD
CVE Published
Aug 19, 2026 - 21:35 cve.org
HIGH 7.4

DescriptionCVE.org

In Splunk Connect for Kafka versions below 2.2.7, an unauthenticated user positioned in the network path could read or alter all relevant data sent from the connector when Kerberos authentication is used with Hypertext Transfer Protocol (HTTP) Event Collector in Splunk Enterprise. The vulnerability is possible because the Kerberos authentication path does not apply the configured certificate validation options when it builds the HTTP client. For more information see Install Splunk Connect for Kafka (https://help.splunk.com/en/data-management/integrate-data-with-add-ons/splunk-connect-for-kafka/2.2/install/install-splunk-connect-for-kafka), Security configurations for Splunk Connect for Kafka (https://help.splunk.com/en/splunk-enterprise/get-data-in/splunk-connect-for-kafka/2.2/configure/security-configurations-for-splunk-connect-for-kafka), and Set up and use HTTP Event Collector with configuration files (https://help.splunk.com/en/splunk-enterprise/get-data-in/get-started-with-getting-data-in/9.4/get-data-with-http-event-collector/set-up-and-use-http-event-collector-with-configuration-files) in the Splunk documentation.

AnalysisAI

Certificate validation bypass in Splunk Connect for Kafka below version 2.2.7 allows a network-positioned unauthenticated attacker to intercept and modify event data in transit to Splunk Enterprise's HTTP Event Collector when Kerberos authentication is configured. The Kerberos code path fails to apply the connector's configured TLS certificate validation options when constructing the HTTP client, effectively negating transport security despite HEC's TLS configuration. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
Gain Layer-2 or routing access to connector network
Delivery
Redirect connector-to-HEC TLS traffic via MitM proxy
Exploit
Present forged TLS certificate to connector
Execution
Connector accepts certificate (validation skipped in Kerberos path)
Persist
Decrypt and read or modify event stream
Impact
Forward (optionally tampered) data to Splunk HEC

Vulnerability AssessmentAI

Exploitation Exploitation requires two specific preconditions: (1) Kerberos authentication must be the configured authentication method for the connector's HEC connection - deployments using token-based or other HEC authentication methods are not affected by this code path defect; (2) the attacker must achieve a network man-in-the-middle position between the Kafka connector and the Splunk HEC endpoint, which requires either compromised network infrastructure, Layer 2 access to the same network segment, or the ability to manipulate routing. … Additional conditions and limiting factors are described in the full assessment.
Risk Assessment The CVSS 3.1 score of 7.4 (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N) reflects an accurate picture: network attack vector is correct since the connector communicates with HEC over a network path, but AC:H appropriately captures the requirement that the attacker must be physically or logically interposed in the network path (e.g., via ARP spoofing, rogue routing, or compromised network infrastructure). … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario An attacker with access to a network segment between the Kafka connector host and the Splunk HEC endpoint performs ARP poisoning or BGP route injection to redirect connector-to-HEC traffic through an attacker-controlled proxy. Because the Kerberos code path skips certificate validation, the connector accepts the attacker's self-signed or forged certificate, allowing full decryption of the TLS stream. …
Remediation Upgrade Splunk Connect for Kafka to version 2.2.7 or later, which is the vendor-confirmed patched release per EUVD-2026-62968 and the Splunk advisory at https://advisory.splunk.com/advisories/SVD-2026-0808. … Detailed patch versions, workarounds, and compensating controls in full report.

Recommended ActionAI

Within 24 hours, identify all systems running Splunk Connect for Kafka versions below 2.2.7 and document which deployments use Kerberos authentication with HTTP Event Collector, as these are directly vulnerable to the certificate validation bypass. …

Sign in for detailed remediation steps and compensating controls.

Threat intelligence, references, and detailed analysis are available after sign-in.

More in Splunk

View all
CVE-2026-20253 CRITICAL POC
9.8 Jun 10

Unauthenticated arbitrary file write in Splunk Enterprise (below 10.2.4 and 10.0.7) and Splunk Cloud Platform (below 10.

CVE-2024-36985 HIGH POC
8.8 Jul 01

In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10, a low-privileged user that does not hold the admin or powe

CVE-2023-46214 HIGH POC
8.8 Nov 16

In Splunk Enterprise versions below 9.0.7 and 9.1.2, Splunk Enterprise does not safely sanitize extensible stylesheet la

CVE-2023-32707 HIGH POC
8.8 Jun 01

In versions of Splunk Enterprise below 9.0.5, 8.2.11, and 8.1.14, and Splunk Cloud Platform below version 9.0.2303.100,

CVE-2022-43571 HIGH POC
8.8 Nov 03

In Splunk Enterprise versions below 8.2.9, 8.1.12, and 9.0.2, an authenticated user can execute arbitrary code through t

CVE-2022-43567 HIGH POC
8.8 Nov 04

In Splunk Enterprise versions below 8.2.9, 8.1.12, and 9.0.2, an authenticated user can run arbitrary operating system c

CVE-2026-54511 HIGH POC
8.6 Aug 26

Log injection in @logtape/syslog allows network-accessible attackers to forge arbitrary syslog records in downstream col

CVE-2023-22934 HIGH POC
8.0 Feb 14

In Splunk Enterprise versions below 8.1.13, 8.2.10, and 9.0.4, the ‘pivot’ search processing language (SPL) command lets

CVE-2022-43566 HIGH POC
8.0 Nov 04

In Splunk Enterprise versions below 8.2.9, 8.1.12, and 9.0.2, an authenticated user can run risky commands using a more

CVE-2024-36991 HIGH POC
7.5 Jul 01

In Splunk Enterprise on Windows versions below 9.2.2, 9.1.5, and 9.0.10, an attacker could perform a path traversal on t

CVE-2024-36990 MEDIUM POC
6.5 Jul 01

In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10 and Splunk Cloud Platform versions below 9.2.2403.100, an a

CVE-2017-17067 CRITICAL
9.8 Nov 30

Splunk Web in Splunk Enterprise 7.0.x before 7.0.0.1, 6.6.x before 6.6.3.2, 6.5.x before 6.5.6, 6.4.x before 6.4.9, and

Share

EUVD-2026-62968 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy