Skip to main content

Ac7 Firmware EUVDEUVD-2026-16809

| CVE-2026-4974 HIGH
Buffer Overflow (CWE-119)
2026-03-27 cna@vuldb.com
7.4
CVSS 4.0 · Vendor: vuldb
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Authenticate to Tenda AC7 web interface
  2. Delivery
    Send POST request to /goform/SetSysTimeCfg
  3. Exploit
    Inject oversized Time parameter
  4. Execution
    Trigger stack-based buffer overflow
  5. Impact
    Execute arbitrary code with device privileges

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, buffer size validation
MITRE ATT&CK

2 techniques across 2 tactics: Execution, Privilege Escalation

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Requires authenticated access to Tenda AC7 router (firmware 15.03.06.44). Attacker must be a logged-in user with access to the /goform/SetSysTimeCfg POST endpoint to send a crafted Time parameter triggering stack-based buffer overflow.

Impact

The CVSS 4.0 score of 7.4 reflects high severity with complete confidentiality, integrity, and availability impact (VC:H/VI:H/VA:H). The attack vector analysis shows network-accessible exploitation (AV:N) with low complexity (AC:L) requiring only low privileges (PR:L), making this highly practical to exploit. The CVSS E:P metric confirms proof-of-concept exploit code exists and has been publicly disclosed via the Notion document reference, significantly lowering the barrier to exploitation. While no CISA KEV listing or EPSS score is provided in the data, the combination of public exploit availability, low attack complexity, authenticated but low-privilege requirement, and complete system impact elevates real-world risk substantially. The authentication requirement (PR:L) provides minimal protection since consumer routers often have default credentials or weak passwords. For organizations using Tenda AC7 routers in production environments, this represents an immediate priority requiring emergency patching or device replacement, as authenticated network access to router management interfaces is commonly achievable by internal threat actors or via credential compromise.

Exploit ScenarioDerived

An attacker who has obtained low-privilege credentials to the Tenda AC7 web management interface (through credential stuffing, default passwords, or social engineering) connects to the router over the network and sends a malicious POST request to /goform/SetSysTimeCfg with an oversized Time parameter value crafted to overflow the stack buffer. This overwrites the return address on the stack, redirecting execution to attacker-controlled shellcode that establishes persistent backdoor access to the router, allowing traffic interception, DNS hijacking, or pivot points into the internal network. Publicly available exploit code exists demonstrating this attack path, making exploitation straightforward for actors with basic network access.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.0% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 27, 2026

Stack-based buffer overflow in Tenda AC7 router firmware 15.03.06.44 allows authenticated remote attackers to execute arbitrary code via crafted Time parameter to /goform/SetSysTimeCfg endpoint. Publicly available exploit code exists. EPSS data not available, but exploitation requires low attack complexity with network access and low privileges (CVSS:4.0 AV:N/AC:L/PR:L). This is a critical pre-authentication boundary issue in consumer router infrastructure with confirmed POC, warranting immediate patching for affected deployments.

RemediationAI

No vendor-released patch identified at time of analysis based on available data. Organizations using Tenda AC7 firmware version 15.03.06.44 should immediately check the official Tenda support portal at https://www.tenda.com.cn/ for updated firmware releases addressing this vulnerability. As an interim risk mitigation measure, restrict network access to the router's administrative interface (/goform/ endpoints) to trusted management networks only, implement strong non-default administrative credentials, disable remote management features if not operationally required, and consider placing affected devices behind additional network segmentation controls. Given the severity and public exploit availability, organizations should prioritize firmware updates as soon as vendor patches become available, or evaluate replacing affected devices with alternative router models if Tendalavender-bicycle-a5a.notion.site/Tenda-AC7-fromSetSysTime-32153a41781f801c95b0f8a53eaa9a1f for technical exploitation details and monitor VulDB tracking at https://vuldb.com/?id.353861 for patch status updates.

Affected VersionsENISA

AC7 15.03.06.44

Affected Packages

euvd ac7 no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability affects the fromSetSysTime function within the POST request handler for the SetSysTimeCfg configuration interface in Tenda AC7 wireless routers running firmware version 15.03.06.44. The flaw is classified as CWE-119 (Improper Restriction of Operations within the Bounds of a Memory Buffer), specifically manifesting as a stack-based buffer overflow. The vulnerability occurs when processing the Time parameter in POST requests to /goform/SetSysTimeCfg, where insufficient input validation allows an attacker to overflow stack memory by sending a crafted Time value exceeding allocated buffer space. This is a common vulnerability class in embedded device web management interfaces where C-based firmware implementations lack proper bounds checking on user-supplied configuration parameters. The stack-based nature of the overflow means attackers can potentially overwrite return addresses and execute arbitrary code in the context of the router's web server process.

Know when Ac7 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (vuldb) PRIMARY 7.4 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P

Primary rating from Vendor (vuldb) · only source for this CVE.

CVSS VectorVendor: vuldb

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

DescriptionCVE.org

A flaw has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg of the component POST Request Handler. Executing a manipulation of the argument Time can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.

Executive ViewAI

Why It Matters

Tenda AC7 router firmware version 15.03.06.44 contains a stack-based buffer overflow vulnerability that allows authenticated attackers to execute arbitrary code on affected devices. This vulnerability directly impacts network perimeter security for any organization or individual deploying these routers, potentially compromising all downstream network traffic and connected systems. Immediate firmware assessment and replacement planning are required.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations: restrict administrative access to the affected router to trusted networks only, disable remote management features, monitor the /goform/SetSysTimeCfg endpoint for suspicious requests, and prioritize replacement with actively-supported router firmware.

Threat Intelligence Overview

EPSS Score
0.0%
Top 86% exploitable
Data Quality
6 sources
Confidence: High

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.0%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
Poc
System Exposure· derived
Open
Automatable
No
Human Impact
High
Technical Impact
Total

Priority Score

37
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +37
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

CVE-2025-29137 CRITICAL POC
9.8 Mar 19

Tenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set f

CVE-2024-32301 CRITICAL POC
9.8 Apr 17

Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle fun

CVE-2023-41562 CRITICAL POC
9.8 Aug 30

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered

CVE-2023-41559 CRITICAL POC
9.8 Aug 30

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to co

CVE-2023-41558 CRITICAL POC
9.8 Aug 30

Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeC

CVE-2023-41557 CRITICAL POC
9.8 Aug 30

Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter

CVE-2023-41556 CRITICAL POC
9.8 Aug 30

Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to co

CVE-2023-41555 CRITICAL POC
9.8 Aug 30

Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasi

CVE-2023-41552 CRITICAL POC
9.8 Aug 30

Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parame

CVE-2023-38937 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC

CVE-2023-38936 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28,

CVE-2023-38933 CRITICAL POC
9.8 Aug 07

Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0